GREENSTYLE PLUS
SINGLE SPLIT AIR CONDITIONERS-R32
INDOOR UNIT
GREENSTYLE PLUS 9000 UI
GREENSTYLE PLUS 12000 UI
GREENSTYLE PLUS 18000 UI
GREENSTYLE PLUS 24000 UI
OUTDOOR UNIT
GREENSTYLE PLUS 9000 UE
GREENSTYLE PLUS 12000 UE
GREENSTYLE PLUS 18000 UE
GREENSTYLE PLUS 24000 UE
Please read this manual carefully before installing and using the air conditioner, and retain for future
reference.
EN
USER MANUAL and INSTALLATION GUIDE
33V 11/22
INDEX
General warnings
Safety precautions
Notices for usage
Description of parts
Remote control guide
WiFi guide (optional)
Cleaning and care
Troubleshooting
Notices for the installation
Indoor unit installation
Outdoor unit installation
Maintenance notes
Warnings for the refrigeration system specialist
3
4
6
7
8
12
15
16
17
21
23
26
27
REQUIREMENTS FOR INSTALLATION AND MAINTENANCE PERSONNEL
All personnel who carry out installation and/or maintenance operations on the units must be equipped with PEF
(European Refrigerators License) as required by the D.P.R. n. 146/2018 implementing Regulation (EU) no. 517/2014.
If another technician is required to maintain and repair the equipment, this will need to be supervised by the person
who is qualied to use ammable refrigerants. The repair must be performed according to the methodology indicated
by the manufacturer of the equipment. If you need to install, move or service the air conditioner, please contact your
dealer or local service center for the procedure rst. The air conditioner must be installed, moved or maintained by
authorized personnel. Failure to do so could result in serious damage, personal injury or death.
34V 11/22
THE REFRIGERANT R32
GENERAL WARNINGS
Appliance lled with ammable
gas R32.
To realize the function of the air conditioner unit, a special refrigerant circulates in the system. The refrigerant is
the uoride R32 = GWP (Global warming potential). This refrigerant is ammable and inodorous. It can lead to
explosions under certain conditions, however the ammability of this refrigerant is very low and it can be ignited
only by re.
Compared to other common refrigerants, R32 is a non-polluting refrigerant with no harm to the ozonosphere and
a lower effect upon the greenhouse effect. R32 has very good thermodynamic features which lead to a really high
energy efciency. The units therefore need less lling.
Warning:
Do not try to accelerate the defrosting process or to clean the appliance in different ways other than those recommended
by the manufacturer. Should repair be necessary, contact your nearest authorized Argoclima Service Centre. Any
repairs carried out by unqualied personnel may be dangerous. The appliance has to be stored in a room that doesn’t
have any continuously operating ignition sources. (for example: open ames, an operating gas appliance or an
operating electric heater.) Do not pierce or burn. Appliance has to be installed, operated and stored in a room with a
oor area larger than X m2. (Please refer to table “a” in section of “ Safety Operation of Inammable Refrigerant” for
Space X.) For repairs, strictly follow manufacturer’s instructions only for appliances lled with R32 ammable gas. Be
aware that refrigerants do not have any odour.
Before using the appliance,
read the owner’s manual.
Before installing the appliance,
read the installation manual. Before repairing the appliance, read the
service manual.
35V 11/22
SAFETY PRECAUTIONS
This appliance can be used by children aged from 8 years and above
and persons with reduced physical, sensory or mental capabilities or
lack of experience and knowledge if they have been given supervision
or instruction concerning use of the appliance in a safe way and
understand the hazards involved. Children shall not play with the
appliance. Cleaning and user maintenance shall not be made by
children without supervision.
The air conditioner must be grounded. Incomplete grounding may result
in electric shocks. Do not connect the earth wire to the gas pipeline,
water pipeline, lightning rod, or telephone earth wire.
Always switch off the device and cut the power supply when the unit is
notin use for long time so as to ensure safety.
Take care not let the remote control and the indoor unit watered or
being too wet. Otherwise, it may cause short circuit.
If the supply cord is damaged, it must be replaced by the manufacturer,
its service agent or similarly qualied persons in order to avoid a hazard.
Don’t cut off main power switch during operating or with wet hands. It
may cause electric shock.
Don’t share the socket with other electric appliance. Otherwise, it may
cause electric shock even re and explosion.
Always switch off the device and cut the power supply before performing
any maintenance or cleaning. Otherwise, it may cause electric shock
or damage.
Don’t pull the power cable. The damage of pulling power cord will
cause serious electric shock.
A warning that ducts connected to an appliance shall not contain an
ignition source.
Don’t install air conditioner in a place where there is ammable gas or
liquid. The distance between them should above 1 m. It may cause re
even explosion.
Don’t use liquid or corrosive cleaning agent wipe the air conditioner
and sprinkle water or other liquid either.
Don’t attempt to repair the air conditioner by yourself. Incorrect repairs
may cause re or explosion. Contact a qualied service technician for
all service requirement.
Don’t use air conditioner in lightning storm weather. Power supply should
WARNING
36V 11/22
be cut in time to prevent the occurrence of danger.
Don’t put hands or any objects into the air inlets or outlets. This may
cause personal injury or damage to the unit.
Please note whether the installed stand is rm enough or not. If it is
damaged, it may lead to the fall of the unit and cause the injury.
Don’t block air inlet or air outlet. Otherwise, the cooling or heating
capacity will be weakened, even cause system stop operating.
Don’t let the air conditioner blow against the heater appliance. Otherwise
it will lead to incomplete combustion, thus causing poisoning.
The appliance shall be installed in accordance with national wiring
regulations. An earth leakage breaker with rated capacity must be
installed to avoid possible electric shocks.
Don’t open the windows and doors for long time when the air
conditioner is running. Otherwise, the cooling or heating capacity will
be weakened.
Don’t stand on the top of the outdoor unit or place heavy things on it.
This cloud cause personal injuries or damage the unit.
Don’t use the air conditioner for other purposes, such as drying clothes,
preserving foods, etc.
Don’t apply the cold air to the body for a long time. It will deteriorate
your physical conditions and cause health problems.
Set the suitable temperature. It is recommended that the temperature
difference between indoor and outdoor temperature should not be too
large. Appropriate adjustments of the setting temperature can prevent
the waste of electricity.
If your air conditioner is not tted with a supply cord and a plug, an
anti-explosion all-pole switch must be installed in the xed wiring and
the distance between contacts should be no less than 3.0 mm.
Fuse Type: T3.15AH250V, the electricity passing through the fuse cannot
be higher than 3.15A. For the air conditioner permanently connected to
an outlet, equip the line with a power switch. The current switch must be
single-pole, with a distance between the contacts greater than 3 mm and
a residual nominal value not greater than 30 mA. The power supply circuit
must have a leakage protection device and an air switch whose rated
capacity should be greater than 1.5 times the maximum current.
37V 11/22
NOTICES FOR USAGE
OPERATING RANGE
Cooling mode: from +16 °C to +49 °C (outdoor temperature)
Heating mode: from -15 °C to +30 °C (outdoor temperature)
When the temperature is too high, the air conditioner may activate the automatic protection device, so that the
air conditioner could be shut down.
When the temperature is too low, the heat exchanger of the air conditioner may freeze, leading to water dripping
or other malfunction.
In long-term cooling or dehumidication with a relative humidity of above 80% (doors and windows are open),
there may be water condenses or dripping near the air outlet.
NOTES FOR HEATING FUNCTION
When the heating function is started, the indoor unit fan will not work immediately to avoid the introduction of
insufciently hot air into the environment.
When the outdoor temperature is very low and the humidity is high, ice may form on the heat exchanger of the
outdoor unit. Then the air conditioner will start defrost function.
During defrost, the air conditioner will stop heating for about 5-12 minutes.
Vapor may come out from the outdoor unit during defrost. This is not a malfunction, but a result of fast defrost.
Heating will resume after defrost is complete.
NOTES FOR TURNING OFF
When the air conditioner is turned off, the unit may continue to ventilate for a few minutes to help dry the battery
of the indoor unit.
EMERGENCY OPERATION
If the remote control is faulty, use the emergency button located under the front
panel of the indoor unit (see image).
If this button is pushed with the unit OFF, the air conditioner will operate in Auto
mode.
If this button is pushed with the unit ON, the air conditioner will stop running.
AIRFLOW DIRECTION ADJUSTMENT
1. Use the vertical oscillation button on the remote control to set the direction of
the air ow.
2. It is possible to direct the air ow also horizontally; this operation is only
possible manually, by moving the air delivery aps as desired (see image).
Note: move the air aps before the unit is in operation, or your nger might be
injured.
Never place your hand into the air inlet or outlet when the air conditioner is in operation.
INFORMATION FOR CORRECT DISPOSAL OF THE PRODUCT IN ACCORDANCE WITH THE
EUROPEAN DIRECTIVE 2012/19/EU
At the end of its working life this equipment must not be disposed of as an household waste. It must be
taken to special local community waste collection centres or to a dealer providing this service. Disposing
of electrical and electronic equipment separately avoids possible negative effects on the environment
and human health deriving from an inappropriate disposal and enables its components to be recovered
and recycled to obtain signicant savings in energy and resources. In order to underline the duty to
dispose of this equipment separately, the product is marked with a crossed-out dustbin
Emergency
button
38V 11/22
DESCRIPTION OF PARTS
INDOOR UNIT
OUTDOOR UNIT
Note: all the illustrations in this manual are for explanation purpose only. Your air conditioner may be slightly
different. The actual shape shall prevail.
Air inlet
Air outlet
Emergency button
Pipe protection
ring
Air inlet grille
Air filter
Air flap
Air louver
Panel
Remote controller
Air outlet
Air inlet
Air outlet grille
Power cable
Connecting
pipe
Drain hose
Uscita aria
REMOTE CONTROL USER GUIDE
1. At rst time use of the remote controller, install the batteries and ensure that the “+”and “-” poles are correctly
positioned. To insert the batteries, follow the instructions below:
Slide to open the cover according to the direction indicated by the arrowhead (Fig.1)
lnsert two brand new batteries, and position the batteries to the right electric poies (Fig.2).
Put back the cover according to the direction indicated by the arrowhead (Fig.3)
2. Ensure the remote controller is pointed to the signal receiving window, and that there is no obstruction in between
and the distance is 8m at the maximum.
3. Do not let the remote controller drop or ing it at will. Do not let any liquid in the remote controller.
4. Do not expose the remote controller directly to the sunlight or excessive heat.
5. lf the remote controller does not work normally, remove the batteries far 30 seconds before reinstall them. lf that
doesn’t work, replace the batteries.
6. When replacing the batteries, do not mix the new batteries with old ones or mix batteries of different types, which
could cause failure of the remote controller.
Fig.1 Fig.2 Fig.3
39V 11/22
INFORMATION FOR THE CORRECT DISPOSAL OF BATTERIES IN ACCORDANCE WITH EUROPEAN
DIRECTIVE 2006/66/EC and MODIFICATIONS INTRODUCED BY DIRECTIVE 2013/56/EU
Replace batteries when they are depleted. At the end of their life, batteries must be disposed of separately
from unsorted waste. They must be taken to designated recycling centres or returned to a retailer
providing this service. Separate disposal of batteries helps to reduce the potential harmful effects on the
environment and human health caused by their improper disposal and also enables the recovery and
recycling of component materials, saving signicant energy and resources. The requirement for separate
disposal is indicated by the crossed-out wheelie bin label afxed to the appliance. Illegal disposal of the
product by the user is subject to administrative penalties as per current regulations.
7. lf the remote controller is not to be used far a long period of time, remove the batteries rst, lest the leakage from
them may damage the remote controller.
8. Properly dispose the discarded batteries.
BUTTONS DESCRIPTION
1. ON/OFF BUTTON
With this button you can turn the unit on or off. This button can also be used to reset the timer and the SLEEP
function.
2. °C/°F BUTTON
Press this button to select the temperature unit of measurement, the selectable units are Fahrenheit (°F) or Celsius
(°C) which is the default unit. When pressed for the rst time, °F will be selected, and the °C symbol will no longer
appear on the display. Press again to select °C.
Note: some models do not have the possibility to select the temperature in °F; this means that when the °C/°F”
button is pressed, the °F symbol may appear on the remote control display, but the temperature will continue to be
displayed in °C on that of the air conditioner.
40V 11/22
3. SPEED BUTTON
Press this button, you can select the fan speed as follows:
Note: AUTO air speed is not available in FAN mode.
4. DISPLAY BUTTON
It is possible to turn the remote control display on or off, while the unit is running, to extend the life of the batteries.
5. iFEEL BUTTON
Pressing this button activates the IFeel function. The LCD screen shows the room temperature and when the function
is canceled it shows the set temperature. This function is not active in AUTO and FAN mode.
6. TIMER BUTTON
When the air conditioner is on, press this button to deactivate the TIMER function, or when it is off to activate it.
When the button is pressed, the display will show “ON (OFF)” ashing. It is possible to press the “ and “
“ buttons to set the timer, each press will increase or decrease the timer by 0.5 h up to 10 h, then the time
interval will be 1h. The settable range is 0.5-24 h. Press the “TIMER” button again to activate the function, the
“ON (OFF)” symbol will stop ashing. If the “TIMER” button is not pressed for 10 seconds while the “ON (OFF)”
symbol ashes on the display, the TIMER function will be canceled. If the TIMER function is active, pressing this
button will deactivate it.
Note: when the TIMER function is active, all function buttons (except SLEEP, DISPLAY and iFEEL) are usable.
7. HEALTH/iCLEAN BUTTON
This button has two functions:
HEALTH: function not available.
iCLEAN: When the remote control is off, press the “iClean” button to activate the “iClean” function with a
maximum duration of 30 minutes. The purpose of this function is to clean the evaporator from dust, dry the
water inside the evaporator and prevent the formation of mold which can cause the spread of bad odors.
After setting the “iClean” function, press the “iClean” button again to cancel the function or press the ON/
OFF button to cancel the “iClean” function and turn on the appliance. The “iClean” function is deactivated
after 30 minutes of operation if no operation takes place.
Note: the iClean function can be set in parallel with the “Timer on” function; in this case, the “Timer on”
function will be executed after the “iClean” function.
8. BUTTONS
Press the / button to adjust the temperature from 16 °C to 32 °C; the screen will change each time the
button is pressed. Each time you press “ “ the temperature will increase by 1 °C and each time you press “
“ the temperature will decrease by 1 °C.
Note: the temperature cannot be set in AUTO and FAN mode, so these two buttons will have no effect.
9. TURBO BUTTON
Press this button only in COOL or HEAT mode to select the TURBO function and set the maximum fan speed. When
TURBO mode is active, the fan is at maximum speed; When TURBO mode is off, the dispensing speed is restored
to the previous state.
10. MODE BUTTON
Press this button, you can select the running mode as follows:
Note: HEAT mode is not available for cool only units.
11. SLEEP BUTTON
When you press the SLEEP button, the display turns off.
After setting the Sleep mode, in the cooling function, the temperature will increase by 1 ºC in an hour, then
automatically increase by 1 ºC again after another hour. After setting the Sleep mode, in the heating function, the
temperature will decrease by 2 ºC after an hour, then automatically decrease by 2 ºC again after another hour.
After 10 hours of operation in SLEEP mode the air conditioner returns to the previous functions and automatically
41V 11/22
turns off. The ventilation speed will automatically switch to the lowest level available to ensure maximum quiet
operation during night rest.
Note: press the MODE button or the ON/OFF button to cancel the SLEEP function setting. The SLEEP function
cannot be activated in FAN mode.
12. SWING BUTTON (vertical oscillation)
Press this button to set the automatic vertical swing mode, which allows the outer aps to swing from top to bottom
and vice versa. Press this button again to deactivate the SWING function.
13. SWING BUTTON (horizontal oscillation)
This function is not available. However, it is possible to direct the air ow manually, by moving the aps of the
indoor unit horizontally.
14. ANTI-F BUTTON
This air conditioner has a special drying and anti-mold function. This function is controlled by the remote control in
the COOLING, DRY and AUTO modes. When the air conditioner is operating in the heating mode, the indoor
fan runs for three minutes on weak ventilation before stopping. The purpose of this function is to dry the water
inside the evaporator and prevent the formation of mold which can cause the dispersion of a strange odor. This
function is not set by default, it can be freely set and deactivated. The setting method is as follows: when the air
conditioner and remote control are off, point the remote control at the unit and press the “Anti-F” button, the unit
will beep ve times and then indicate that this function is set. Once set, this function remains valid unless the air
conditioning is completely switched off or the function is manually deactivated.
To deactivate the function:
Turn off the unit.
When the air conditioner and the remote control are off, point the remote control at the unit and press this
button, the device emits a sound three times and this indicates that the function is disabled.
Note: when this function is active, it is advisable not to restart the air conditioner before it is completely stopped.
This function will not be active if the unit is switched off or stopped by the “SLEEP” function.
15. ELE.H/ECO BUTTON
ELE.H (function not available)
ECO: if you press this button in COOL mode, the unit will activate the ECO mode which has the lowest
electricity consumption and that is automatically deactivated after 8 h. If you change the mode or turn off the
remote control, the function ECO will be automatically canceled. Press the ECO button in ECO mode to exit
this mode.
OPERATION MODE
Automatic mode (AUTO)
Press the “MODE” button, select the automatic operation mode.
By pressing the “SPEED” button, you can select the fan speed from LOW, MID, HIGH, AUTO.
Press the “ON/OFF” button, the air-conditioner starts to operate.
Press the “ON/OFF” button again, the air-conditioner stops.
COOLING mode: The default set temperature is 20 °C. When the ambient temperature exceeds 20 °C the unit starts
to operate in cooling. Below 20 ºC it only works in ventilation.
HEATING mode: The default set temperature is 25 °C. When in room the temperature is below 25 °C the unit starts
working in heating.
COOLING/HEATING mode
Press the “MODE” button, select the Cooling or Heating operation mode.
By pressing the “ or “ “ you can set the temperature from 16 °C to 32 °C, the display changes as you
touch the button.
By pressing the “SPEED” button, you can select the fan speed from LOW, MID, HIGH, AUTO.
Press the “ON/OFF” button, the air-conditioner starts to operate.
Press the “ON/OFF” button again, the air-conditioner stops.
FAN mode
Press the “MODE” button, select the fan operation mode.
By pressing the “SPEED” button, you can select the fan speed from LOW, MID, HIGH.
Press the “ON/OFF “ button, the air-conditioner starts to operate in FAN mode.
42V 11/22
Press the “ON/OFF” button again, the air-conditioner stops.
DRY mode
Press the “MODE” button, select the drying operation mode.
By pressing the “ “ or “ “ you can set the temperature, the display changes as you touch the button.
By pressing the “SPEED” button, you can select the fan speed from LOW, MIO, HIGH, AUTO.
Press the “ON/OFF” button, the air-conditioner starts to operate.
Press the “ON/OFF” button again, the air-conditioner stops.
The remote controller has a backlight which can be turned on by pressing any button for the convenience of
operation in darkness. The backlight will be automatically turned off if there is no operation within 10 seconds.
WIFI GUIDE (optional)
INTRODUCTION
It is possibile to install the WiFi moudle to remotery control the our conditioner. The AC system is equipped with remote
control technology, with the WI-FI module inside the machine connected to the display panel and the command to
run the AC transmitted. The AC system is in constant connection with a wireless router or access point attached to the
Internet. Mobile terminals such as smart phones and tablet computers, on which special control software are installed
and WI-FI modules successfully congured locally, can be used as remote controllers once they are connected to the
Internet.
DOWNLOAD AND INSTALL THE CONTROL SOFTWARE
The control software can be downloaded and installed as follows.
1. For mobile terminals such as smart phones and tablet (Android 4.1 and iOS 6.0 or above only), search and
download “AC Freedom” from Google Play or App store on and install it on your system.
2. You may also use your mobile terminal (Android 4.1 and iOS 6.0 or above only) to scan the “QR code” (see
Fig.1) with a thirdparty scan tool, which will automatically direct you to the download interface of AC Freedom
for you to download and install the software.
For Android For IOS
43V 11/22
Once the control software is installed, enter the “Scanning Interface” (point 1, Fig.1) for downloading the Home Page.
SCAN Function: by clicking “scan” and scanning the QR code on the right(Fig.2).
After scanning the QR code, enter the activation code “6364d” (point 1, Fig.3) and click on activate (point 2, Fig.3)
RESET AC WI-FI MODULE
In the case of initial conguration or after replacing the connected wireless router, you must reset the Wi-Fi module
inside the air conditioner.
To reset the Wi module, follow these steps:
Turn on the air conditioner and select the FAN mode (ventilation) with the MODE button and the HIGH ventilation
speed (with the SPEED button).
Direct the remote control to the display of the internal unit, then press the “HEALTH” button 8 times; a “beep” will
follow twice, indicating that the reset has been done correctly (Fig.4).
Disconnect the system power for at least 30 seconds.
Note: if the device is not connected successfully, please reset the air conditioner Wi-Fi in the same way.
SMARTPHONE, PAD OR OTHER MOBILES TERMINALS CONNECT TO WIFI OR HOTSPOT
Activate the WI-FI function of the mobile device and connect it to a wireless router or an access point
Note: a wireless router is required for the WI-FI function to work.
Fig.4
RESET button
ON button: air conditioner
access in high-speed FAN mode
1
AcFreedom
Scan the two-dimension code in specification
to activate APP
Skip
2
scan
or
enter activation code activate
1
AcFreedom
Scan the two-dimension code in specification
to activate APP
Skip
2
scan
or
XXX activate
scan
Scan the two-dimension code in specification
to activate APP
cancel
Fig.3Fig.2Fig.1
44V 11/22
CONFIGURATION OF DEVICES
After downloading and installing the app on your smartphone or tablet, you need to add the air conditioner as your
new Wi-Fi device associated according to the following gure:
Note: if the device has not been connected properly, please run the conguration again as described above.
3. For rst time conguration or after the connected wireless router or access point is changed, make sure the mobile
device is already connected to the wireless router or access point to be paired with the WI-FI module.
4. If the conguration is failed, press “Cong faild check items” to check them notes about the failure before
recongure the AC.
After the conguration is successful, click the corresponding AC name to enter the control interface for further
operation.
1. Modify and Lock the Devices
In the “Device List” interface, press and
hold for more than 0.5 second (for Android
system) or press (for IOS system) the icon of
an existing device to activate the “Modify
the name” interface.
You can change the name or the icon, to
identify different AC devices.
To lock a device, simply touch the “Locking
Device” icon. Once a device is locked,
other users won’t be able to search for it,
thus preventing it from hostile control. After
the congurations of the AC device names,
icons and locking status are complete,
touching “Save” will save and validate
them.
2. Delete an AC under control
For Android: Click “Delete Device” button under “Modify the name”
For IOS: Swipe over the AC name to the left under “Device List” and click “Delete”.
Reconnect the power to the system
and start the AC freedom application:
on the mobile device display
(smartphone, tablet) press “+ add
device”.
In the next screen select the type of device to
associate, that is, “conditioner”. On the next page
conrm the reset happened by checking the words
“I nished the previous step”: at that point press
“start”. Then look for the name of the wi network to
which you have to connect and type in the network
password. Then press “connect to wi-”: the system
searches the device to connect to the previously
selected “wi-”.
The air conditioner to associate will
appear on the nal screen. Press “air
conditioner” and conrm with “join
the room”. At this point the device is
connected and the virtual remote will
appear.
Device List
Add device Start the configuration
Add a new device to the WIFI network
WIFI name: XXXXX
|
password:
<<Config failed check items>>
Add device
Device List
Air-conditioner
Add device
13
2
4
1
Device List
Air-conditioner
Add device
2
5
3
4
Delete Device
Modify the name save
Photo
Name Air-conditioner
Locking Device
Firmware Upgrade
Fig.5
45V 11/22
3. Remote control with wireless router
Once the wireless router is connected to the Internet, activating the GPRS on the mobile terminal will enable the
remote control of the devices.
1. The software provides help service through which the users may check the operational instructions of the
software and other information.
2. Besides, as the operation interface and the function of the software is under constant improvement, we will
keep you informed about the subsequent upgrades for your updating.
3. As the operation interface may change due to the constant version upgrading, the gures in this manual are
for reference only, so please rely on the actual operation interface.
APPENDIX “A”: CONFIG FAILED CHECK ITEMS
1. Please check the Wi-Fi icon on the air conditioner panel, if the icon not display, please contact customer service.
2. Please make sure the mobile phone network under the current router WI-FI environment: close the mobile phone
3G/4G data connection, to be connected to the router WI-FI pairing.
3. Please check whether the module is reset successfully. For details, see “Reset AC WI-FI module”.
4. Please check the Wi-Fi name of the router, recommended not contain spaces and other non-alphanumeric
characters.
5. Please check the Wi-Fi password of the router, not allowed more than 32 bits, recommended not contain spaces
and special symbols in addition to letters and numbers.
6. Please check whether the Wi-Fi password input is correct when APP conguration: you can check show password
to conrm when input the WI-FI password.
CLEAN AND CARE
Before the cleaning of the air conditioner, it must be shut down and the electricity must be cut off for more than 5
minutes, otherwise there might be the risk of electric shocks.
Do not wet the air conditioner, which can cause an electric shock. Make sure not to rinse the air conditioner with
water under any circumstances.
Volatile liquids such as thinner or gasoline will damage the air conditioner housing, therefore please clean the
housing of air conditioner only with soft dry cloth and damp cloth moistened with neutral detergent.
In the course of the usage, pay attention to cleaning the lter regularly, to prevent the accumulation of dust
which may affect the air conditioner performance. If the service environment of the air conditioner is dusty,
correspondingly increase the number of times of cleaning. After removing the lter, do not touch the n part of the
indoor unit with the nger, and no force to damage the refrigerant pipeline.
CLEAN THE PANEL
Clean the front panel of the indoor unit with a cloth and lukewarm water, below 40 °C. Do
not disassemble the panel for cleaning.
CLEAN THE AIR FILTER
Remove the air lter
Use both hands to open the panel for an angle from both
ends of the panel in accordance with the direction of the
arrow. Release the air lter from the slot and remove it.
WARNING
46V 11/22
Clean the air lter
Use a vacuum cleaner or water to rinse the lter, and if the lter is very dirty (for
example, with greasy dirt), clean it with warm water (below 45 °C) with mild
detergent, and then put the lter in the shade to dry in the air.
Mount the air lter
Reinstall the dried lter in reverse order of removal, then
cover and lock the panel.
CHECK BEFORE USING
1. Check whether all the air inlets and outlets of the units are unblocked.
2. Check whether there is blocking in the water outlet of the drain pipe, and immediately clean it up if any.
3. Check the ground wire is reliably grounded.
4. Check whether the remote control batteries are installed, and whether the power is sufcient.
5. Check whether there is damage in the mounting bracket of the outdoor unit, and if any, please contact our local
service center.
MAINTENANCE AFTER USING
1. Cut off the power source of the air conditioner, turn off the main power switch and remove the batteries from the
remote controller.
2. Clean the lter and the unit body.
3. Remove the dust and debris from the outdoor unit.
4. Check whether there is damage in the mounting bracket of the outdoor unit, and if any, please contact our local
service center.
Do not repair the air conditioner by yourself as wrong maintenance may cause electric shock or re or explode, please
contact the authorized service center and let the professionals conduct the maintenance, and checking the following
items prior to contacting for maintenance can save your time and money.
TROUBLESHOOTING
WARNING
Phenomenon Causes Troubleshooting
The air conditioner does not work
There might be power outages.
Power plug may be loose out from the
socket.
Power switch fuse may blow.
The time for timing boot is yet to come.
Wait until power is restored.
The plug in the plug tightly.
Replace the fuse.
Wait or cancel the timer settings.
The air conditioner can’t run after the immediate
start-up after it is shut down
If the air conditioner is turned on immediately
after it is turned off, the protective delay
switch will delay the operation.
Wait for 3/5 minutes and try again
The air conditioner stops running after it starts
up for a while
May have reached the setting temperature.
May be at a defrosting state.
Shutdown Timer may be set.
It is a normal function phenomenon.
It will automatically restore and run again
after defrosting.
If you continue to use, please turn it on
again.
The wind blows out, but the cooling/heating
effect is not good
Excessive accumulation of dust on lter,
blocking at air inlet and outlet, and the
excessively small angle of the louver blades
all will affect the cooling and heating effect.
Poor cooling and heating effect caused by
doors and windows opening, and unclosed
exhaust fan.
Mode setting is incorrect, and the
temperature and wind speed settings are
not appropriate.
Please clean the lter, remove the obstacles
at the air inlet and outlet and regulate the
angle of the louver blades.
Please close the doors, windows, the
exhaust fan, etc.
Please re-select the mode, and set the
appropriate temperature and wind speed.
47V 11/22
WARNING
Immediately stop operation of the appliance, disconnect the electricity and contact the nearest Technical Assistance
Centre in the following cases:
Hear any harsh sound or smell any awful odor during running.
Abnormal heating of power cable and plug occurs.
The unit or remote controller has any impurity or water.
Air switch or leakage protection switch is often disconnected.
SAFETY OPERATION OF FLAMMABLE REFRIGERANT
Qualication requirement for installation and maintenance
All workers who engage with the refrigeration system should bear the valid certication awarded by the authoritative
organization, and the qualication recognized by the industry for dealing with the refrigeration system.
The refrigeration system can only be repaired following the methods suggested by the equipment’s manufacturer.
Installation notes
The air conditioner mustn’t be used in a room that has running re or heat sources (such as, working coal gas
ware, operating heater).
Do not drill holes in the circuit or burn the connection pipe.
The air conditioner must be installed in a room that is larger than the minimum room area. The minimum room area
is shown on the following “table a”.
Leak test is mandatory after installation.
NOTICES FOR INSTALLATION
The indoor unit blows out odor
The air conditioner itself does not have
undesirable odor. If there is odor, it may
be due to accumulation of the odor in the
environment.
Clean the air lter or activate the cleaning
function.
There is sound of running water during the
running of air conditioner
When the air conditioner is started up or
stopped, or the compressor is started up
or stopped during the running, sometimes
the “hissing” sound of running water can
be heard.
This is the sound of the ow of the
refrigerant, not a malfunction.
A slight “click” soundis heard at the of start-up
or shut-down
Due to temperature changes, panel and
other parts will swell, causing the sound of
friction.
This is normal, not a fault.
The indoor unit makes abnormal sound
The sound of fan or compressor relay
switched on or off. When the defrosting is
started or stop running, it will create sound.
Too much dust accumulation on the air lter
of the indoor unit may result in uctuation
of the sound.
Too much air noise when “Strong wind” is
turned on.
That is due to the refrigerant ows to reverse
direction. They are not malfunctions.
Clean the air lters in time.
This is normal, if feeling uncomfortable,
please deactivate the “strong wind”
function.
There are water drops over the surface of the
indoor unit
When ambient humidity is high, water
drops will be accumulated around the air
outlet or the panel, etc.
Prolonged cooling run in open space
produces water drops.
Too small opening angle of the louver
blades may also result in water drops at
the air inlet.
This is a normal physics phenomenon.
Close the doors and windows.
Increase the angle of the louver blades.
During the cooling operation, the indoor unit
outlet sometimes will blow out mist.
When the indoor temperature and humidity
are high, it happens sometimes.
This is because the indoor air is cooled
rapidly. After it runs for some time, the
indoor temperature and humidity will be
reduced and the mist will disappear.
48V 11/22
TABLE A - Minimum room area (m2)
Maintenance notes
Check whether the maintenance area or the room area meet the requirement of “table a” the unit is only allowed
to be operated in rooms that meet these requirements.
Check whether the maintenance area is well-ventilated. The continuous ventilation status should be kept during the
entire operation process.
Check whether there is a re source or potential re source in the maintenance area. Running re is prohibited in
the maintenance area and the “no smoking” sign should be hanged.
Check whether the warning sign is in good condition, otherwise replace it.
Welding
If it is necessary to cut or weld the refrigerant system pipes in the maintenance procedures, please follow the steps
here below:
Shut down the unit and cut power supply
Eliminate the refrigerant
Vacuum with a vacuum machine
Clean the pipes with the N2 gas
Cut and weld or
Bring the unit to a service centre for welding
The refrigerant should be recycled in a specialized storage tank.
Make sure there aren’t any free ames near the outlet of the vacuum pump and that it’s well-ventilated.
Filling the refrigerator circuit
Use refrigerant lling appliances specialized for R32. Make sure that different kinds of refrigerant don’t contaminate
one another.
The refrigerant tank should be kept upright when lling with the refrigerant.
Stick the label on the system after lling is nished.
Don’t overll.
After lling is nished, please test the unit for leakage detection before the operation test; another test for leakage
detection should be carried out when the refrigerant is removed.
Safety instructions for transportation and storage
Please use a ammable gas detector to check before unloading and opening the container.
No re source and no-smoking.
According to the local rules and laws.
Before installating, please contact with local authorized maintenance center, if unit is not installed by the authorized
maintenance center, the malfunction may not solved due to discommodious contact.
The air conditioner must be installed by professionals according to the national wiring rules and this manual.
Refrigerant leak test must be made after installation.
To move and install air conditioner to another place, please contact our local special service center.
SAFETY PRINCIPLES FOR INSTALLATION
Fire prevention device shall be prepared before installation.
Keep installing site ventilated (open the door and window)
Ignition source, re, smoking and mobile phones are not allowed to exist in area where R32 refrigerant located.
CAUTION
Minimum room
area (m2)
Charge amount (kg) 1.2 1.3 1.4 1.5 1.6 1.7 1.8 1.9 2 2.1 2.2 2.3 2.4 2.5
Floor location / 14.5 16.6 19.3 22 24.8 27.8 31 34.3 37.8 41.5 45.4 49.4 53.6
Window mounted / 5.2 6.1 7 7.9 8.9 10 11.2 12.4 13.6 15 16.3 17.8 19.3
Wall mounted / 1.6 1.9 2.1 2.4 2.8 3.1 3.4 3.8 4.2 4.6 5 5.5 6
Ceiling mounted / 1.1 1.3 1.4 1.6 1.8 2.1 2.3 2.6 2.8 3.1 3.4 3.7 4
49V 11/22
Keep leak detector in working state during the installation.
If R32 refrigerant leakage occurs during the installation, you shall immediately detect the concentration in indoor
environment until it reaches a safe level. If refrigerant leakage affects the performance of the air conditioner,
please immediately stop the operation, and the air conditioner must be vacuumed rstly and be returned to the
maintenance station for processing.
Keep electric appliance, power switch, plug, socket, high temperature heat source and high static away from the
area underneath sidelines of the indoor unit.
The air conditioner shall be installed in an accessible location to installation and maintenance, without obstacles
that may block air inlets or outlets of indoor/outdoor units, and shall keep away from heat source, inammable
or explosive conditions.
When installing or repairing the air conditioner and the connecting line is not long enough, the entire connecting
line shall be replaced with the connecting line of the original specication; extension is not allowed.
Use new connection pipe, unless re-aring the pipe.
REQUIREMENTS FOR INSTALLATION
Avoid places of inammable or explosive gas leakage or where there are strongly aggressive gases.
Avoid places subject to strong articial electric/magnetic elds.
Avoid places subject to noise and resonance.
Avoid severe natural conditions (e.g. heavy lampblack, strong sandy wind, direct sunshine or high temperature
heat sources).
Avoid places within the reach of children.
Shorten the connection between the indoor and outdoor units.
Select where it is easy to perform service and repair and where the ventilation good.
The outdoor unit shall not be installed in any way that could occupy an aisle, stairway, exit, re escape, catwalk
or any other public area.
The outdoor unit shall be installed as far as possible from the doors and windows of the neighbors as well as the
green plants.
INSTALLATION ENVIRONMENT INSPECTION
Check nameplate of outdoor unit to make sure whether the refrigerant is R32.
Check the oor space of the room. The space shall not be less than usable space(5 m2) in the specication. The
outdoor unit shall be installed at a well-ventilated place.
Check the surrounding environment of installation site: R32 shall not be installed in the enclosed reserved space
of a building.
When using electric drill to make holes in the wall, check rst whether there is pre-buried pipeline for water,
electricity and gas. It is suggested to use the reserved hole in the roof of the wall.
REQUIREMENTS OF WALL INSTALLATION PLATE
The wall installation plate must meet the relevant national or industrial standards in terms of strength with welding
and connection areas rustproofed.
The wall installation plate and its load carry surface shall be able to withstand 4 times or above the weight of the
unit, or 200 kg, whichever is heavier.
The wall installation plate of the outdoor unit shall be fastened with expansion bolt.
Ensure the secure installation regardless of what type of wall on which it is installed, to prevent potential dropping
that could hurt people.
ELECTRICAL SAFETY REQUIREMENTS
Be sure to use the rated voltage and air conditioners dedicated circuit for the power supply, and the power cable
diameter must meet the national requirements.
When the maximum current of air conditioner is 16A, it must use the air switch or leakage protection switch
equipped with protection devices.
The operating range is 90%-110% of the local rated voltage. But insufcient power supply malfunction, electrical
shock, or re. If the voltage instability, proposed to increase the voltage regulator.
50V 11/22
The minimum clearance between the air conditioner and the combustibles is 1.5 m.
The interconnection cord connect the indoor and outdoor units. You must rst choose the right cable size before
preparing it for connection.
Cable Types:
Outdoor Power Cable: H07RN-F or H05RN-F;
Interconnection cord: H07RN-F or H05RN-F;
Minimum Cross-Sectional Area of Power cable and interconnection
cord:
The size of the interconnection cord, power cable, fuse, and
switch needed is determined by the maximum current of the unit.
The maximum current is indicated on the nameplate located on the
side panel of the unit. Refer to this nameplate to choose the right
cable, fuse, or switch.
Note: core number of cable refer to the detailed wiring diagram
adhered on the unit which you purchased.
INSTALLATION WARNINGS
WARNING: Make sure that the power supply is disconnected before carrying out any work on the unit.
WARNING: Wear appropriate personal protective equipment before carrying out any work on the unit.
WARNING: The appliance must be reinstalled in accordance with national system regulations.
WARNING: Wiring and installation must only be performed by a qualied technician trained to install, modify,n
extend and service the unit and perform safety and functionality tests.
WARNING: Install a device, master switch or electric plug that will allow all the power from the appliance to be
switched off.
The following information is essential for correct unit installation. However, the installer should use his or her
experience to install the unit according to specic requirements.
Do not install the unit in locations where there are ammable gases or acid or alkaline substances that may
irreparably damage the copper-aluminium heat exchangers or internal plastic components.
Do not install the unit in ofces or kitchens where oil vapours mixed with treated air may settle on the exchange
coils, reducing performance, or on the unit’s internal parts, damaging the plastic components.
ATTENTION: For the connection between the units, use only annealed and deoxidized copper pipe for
conditioning and refrigeration and insulated with expanded polyethylene of min. 8 mm.
ELECTRICAL CONNECTION REQUIREMENTS
Electrical safety standards must be met when installing the unit.
Use a power supply circuit and circuit breaker that comply with local safety regulations.
Make sure that the power supply matches the requirements of the air conditioner. An unstable power supply or
incorrect wiring may result in a fault. Install suitable power cables before switching on the air conditioner.
Correctly connect the live, neutral and earth wires to the power outlet.
Disconnect the power supply before carrying out any work on the electrical circuit or carrying out any safety work.
For models with a plug, make sure the plug is easily accessible after installation.
Do not connect the power before installation is complete.
Do not use the appliance if the power cable or plug are damaged. If the power cable is damaged it must be
replaced by the manufacturer, retailer or other qualied person to avoid a hazard.
Since the temperature of the cooling circuit is high, keep the interconnecting cable away from the copper pipe.
The unit must be installed in accordance with national wiring regulations.
Installation must only be performed by trained individuals in accordance with regulations.
The unit is charged with a slightly inammable refrigerant, R32. Improper handling of this gas may
expose people and materials to serious damage. More details on this refrigerant are given at the
beginning of this manual.
REQUIREMENTS FOR OPERATIONS AT HEIGHT
When carrying out installation at 2 m or higher above the base level, safety belts must be worn and ropes of
Rated current of
appliance (A) Nominal corss-
sectional area (mm2)
> 3 e 6 0.75
> 6 e 10 1
> 10 e 16 1.5
> 16 e 25 2.5
> 25 e 32 4
> 32 e 40 6
51V 11/22
DIMENSION DRAWING OF INDOOR UNIT INSTALLATION
MOUNTING PLATE
1. The wall for installation of the indoor unit shall be hard and rm, so as to
prevent vibration.
2. Use the “+” type screw to fasten the peg board, horizontally mount the peg
board on the wall, and ensure the lateral horizontal and longitudinal vertical.
3. Pull the peg board by hand after the installation, to conrm whether it is solid.
INSTALLATION OF INDOOR UNIT
Space to the ceiling
15 cm above
Space to the floor
200 cm above
Space to
the wall
20 cm above
Space to the
wall
20 cm above
sufcient strength be securely fastened to the outdoor unit, to prevent falling that could cause personal injury or
death as well as property loss.
GROUNDING REQUIREMENTS
The air conditioner is the class I electrical appliance and must ensure a reliable grounding.
Do not connect the grounding wire to a gas pipe, water pipe, lightning rod, telephone line, or a circuit poorly
grounded to the earth.
The grounding wire is specially designed and shall not be used for other purpose, nor shall it be fastened with a
common tapping screw.
Interconnection cord diameter should be recommended as per instruction manual, and with type O terminal that
meet local standards (internal diameter of type O terminal needs to match the screw size
of the unit, no more than 4.2 mm). After installation, check the screws whether have been
xed effectively, and there is no risk of loosening.
An all-pole isolating switch with a minimum contact gap of 3mm in each pole must be
connected to the xed cable.
Insert a power switch with sufcient power. The air switch must include a magnetic and
thermal function to protect against short circuits and overloads. (Attention: Do not use only
the fuse to protect the circuit)
OTHERS
The connection method of the air conditioner and the power cable and the interconnection method of each
independent element shall be subject to the wiring diagram afxed to the machine.
The model and rating value of the fuse shall be subject to the silkscreen on corresponding controller or fuse sleeve.
Magnetothermal
power switch
9K - 8A
12K - 9.5A
18K - 9A
24K - 13A
52V 11/22
WALL-THROUGH HOLE
1. Make a hole with an electric hammer or a water drill at the predetermined
position on the wall for piping, which shall slant outwardly by 5°-10°.
2. To protect the piping and the cables from being damaged running through
the wall, and from the rodents that may inhabit in the hollow wall, a pipe
protecting ring shall be installed and sealed with putty.
Note: usually, the wall hole is Ø60 mm ~ Ø80 mm. Avoid pre-buried power wire
and hard wall when making the hole.
ROUTE OF PIPELINE
Depending on the position of the unit, the piping may be routed sideway from the left or the right (Fig 1), or vertically
from the back (Fig 2) (depending on the pipe length of the indoor unit).
DRAIN PIPE CONNECTION
1. Remove the xed part to pull out pipe of indoor machine from the case. Screw the hexagon nut in the left of the
joint to the end with your hand.
2. Connect the connecting pipe to the indoor unit: Aim at the pipe center, tighten the Taper nut with ngers, and then
tighten the Taper nut with a torque wrench, and the direction is shown in diagram on the right. The torque used is
shown in the following table.
Note: carefully check if there is any damage of joints before installation. The joints shall not be reused, unless after
re-aring the pipe.
WRAP THE PIPING
1. Use the insulation sleeve to wrap the joint part the indoor unit and the connection
pipe, and then use insulating material to pack and seal insulation pipe, to
prevent generation of condensate water on the joint part.
2. Connect the water outlet with drain pipes, and make the connection pipe,
cables, and the drain hose straight.
3. Use plastic cable ties to wrap the connecting pipes, cables and drain hose.
Run the pipe sloping downward.
Connecting
pipe drain hose
and cables
Connecting
pipe drain hose
and cables
Outlet material
preparation
Fig.1 Fig.2
The size of pipe (mm) Torque (N • m)
Ф6/Ф6.35 15~25
Ф9/Ф9.52 35~40
Ф12/Ф12/Ф7 45~60
Ф15.88 73~78
Ф19.05 75~80
Tightening torque table
Indoor unit pipe
Spanner
Taper nut Connecting pipe
Torque
wrench
Plastic strap
Connecting pipe drain
hose and cables
Pipe
protection
ring
Putty
53V 11/22
FIXING THE INDOOR UNIT
1. Hang the indoor unit on the peg board, and move the unit from left to right to ensure
that the hook is properly positioned in the peg board.
2. Push toward the lower left side and the upper right side of the unit toward the peg
board, until the hook is embedded in the slot and makes a “click” sound.
INTERCONNECTION CORD INSTALLATION
Connect interconnection cord of indoor unit
1. Open the panel, remove the screw on the wiring cover and then
take down the cover.
2. Make the interconnection cord go through the cable-cross hole
at the back of indoor unit and then pull it out from the front side.
(Some models do not have a signal cable).
3. Remove the wire clip; connect the interconnection cord to the
wiring terminal according to the wiring diagram; tighten the screw
and then x the interconnection cord with wire clip.
4. Put wiring cover back and then tighten the screw.
5. Close the panel.
WIRING DIAGRAM
The diagram are for reference only.
Please refer to the detailed wiring
diagram adhered on the unit which
you purchased.
AFTER INSTALLATION CHECK
1. The screws whether have been xed effectively, and there is no risk of loosening.
2. Connector of display board whether put in the right place and do not touch the terminal board.
3. Control box cover whether cover tightly.
Panel
Wiring cover
Signal cable
interconnection
cord
Screw
Variable speed
Connector
If there is a connector,
connect it directly
Constant speed
To outdoor unit To outdoor unit
To outdoor unit
To outdoor unit
54LNS
LLo NS
32(N) 1(L)
5432(N) 1(L)
54V 11/22
DIMENSION DRAWING OF OUTDOOR UNIT INSTALLATION
INSTALLATION OF OUTDOOR UNIT
Space to the obstruction
Air out side
Air in side
10 cm above
200 cm above
30 cm above 50 cm above
50 cm above
Space to the obstruction
Space to the
obstruction
Air outlet
Left installation feet
H
W2
A
D
B
W1
Right installation feet
Air inlet
Outdoor unit size oh shape
W1(W2)*H*D (mm) A (mm) B (mm)
665(710)x420x280 430 280
600(710)x500x240 500 260
730(780)x545x285 540 280
709(761)x536x280 480 283
750(804)x550x285 480 283
800(860)x545x315 545 315
785(845)x555x300 546 316
825(880)x655x310 540 335
900(950)x700x360 632 352
970(1044)x805x395 675 410
940(1010)x1320x370 625 364
940(1008)x1366x401 610 388
650(703)x455x233 480 253
Installation outdoor unit bolt
REFRIGERATING CONNECTIONS
Use equipment and connecting pipes suitable for R32 refrigerator.
Always write the additional refrigerant charge on the data label afxed to the unit outside.
MODELS 9000 12000 18000 24000
Min. - Max. pipe lenght with gas standard
charge (m) 3 - 7 3 - 7 3 - 7 3 - 7
Max. pipe lenght with gas additional charge (m) 20 20 25 25
Additional refrigerant charge (g/m) 15 15 25 25
Max. height between units (outdoor on top) (m) 10 10 15 15
Max. height between units (indoor on top) (m) 10 10 15 15
55V 11/22
INSTALL THE CONNECTION PIPE
Connect the Outdoor Unit with Connecting Pipe: Aim the counter-bore of the connecting
pipe at the stop valve, and tighten the Taper nut with ngers. Then tighten the Taper nut
with a torque wrench.
When prolonging the piping, extra amount of refrigerant must be added so that the
operation and performance of the air conditioner will not be compromised
Note:
1. This table is for reference only.
2. The joints shall not be reused, unless after re-aring the pipe.
3. After installation, check the stop valve cover whether be xed effectively.
WIRING CONNECTION
1. Loosen the screws and remove E-parts cover from the unit.
2. Connect the cables respectively to the corresponding terminals of the
terminal board of the outdoor unit (see the wiring diagram), and if there
are signals connected to the plug, just conduct butt joint.
3. Ground wire: Remove the grounding screw out of the electric bracket,
cover the grounding wire end onto the grounding screw and screw it into
the grounding hole.
4. Fix the cable reliably with fasteners (Pressing board).
5. Put the E-parts cover back in its original place and fasten it with screws.
Insert a circuit breaker with sufcient power and observe the following table:
WIRING DIAGRAM
The diagram are for reference only.
Please refer to the detailed wiring diagram
adhered on the unit which you purchased.
VACUUMING
Exclusive R32 refrigerant pump must be used in making R32 refrigerant vacuum.
Before working on the air conditioner, remove the cover of the stop valve (gas and liquid valves) and be sure to
retighten it afterward (to prevent the potential air leakage).
1. To prevent air leakage and spilling tighten all connecting nut of all are tubes.
Stop valve Taper nut Connection
pipe
Liquid side pipe
Gas side pipe
Spanner
Variable speed
Connector
If there is a connector, connect it directly
Constant speed
To indoor unit
To indoor unit
To indoor unit
To indoor unit To power
To power
To power
To power
L
N
S
L
Lo
N
LN1 3
1 3 45
N(2)
N(2)
LN
S
Piping lenght Amount of refrigerant to be added Amount of refrigerant
for the unit
Not needed
<3M CC12000Btu 20 g/m 1 kg
CC18000Btu 40 g/m 2 kg
3-5M Not needed
5 - 15M CC12000Btu 16 g/m 1 kg
CC18000Btu 24 g/m 2 kg
Magnetothermic
switch power
14K - 16A
56V 11/22
2. Connect the stop valve, charge hose, manifold valve, and vacuum
pump.
3. Fully open the handle Lo of the manifold valve and apply vacuum
for at least 15 minutes and check that the compound vacuum gauge
reads - 0.1MPa (-76cmHg).
4. After applying vacuum, fully open the stop valve with a hex wrench.
5. Check that both indoor and outdoor connections are free of air
leakage.
OUTDOOR CONDENSATION DRAINAGE
When the unit is heating, the condensing water and defrosting water can be
out reliably through the drain house.
Installation: install the outdoor drain elbow in Ф25 hole on the base plate, and joint
the drain hose to the elbow, so that the waste water formed in the outdoor unit can be
drained out to a proper plate.
CHECK AFTER INSTALLATION
Electrical Safety Check
1. If the supply voltage is as required.
2. If there is any faulty or miss connection in each of the power, signal and grounding wires.
3. If the grounding wire of the air conditioner is securely grounded.
Installation Safety Check
1. If the installation is secure.
2. If the water drain is smooth.
3. If the wiring and piping are correctly installed.
4. Check that no foreign matter or tools are left inside the unit.
5. Check the refrigerant pipeline is protected well.
Leak test of the refrigerant
Depending on the installation method, the following methods may be used to check for suspect leak, on areas
such as the four connections of the outdoor unit and the cores of the cut-off valves and t-valves:
1. Bubble method: apply of spray a uniform layer of soap water over the suspected leak spot and observe
carefully for bubble.
2. Instrument method: checking for leak by pointing the probe of the leak detector according to the instruction to
the suspect points of leak.
Note: make sure that the ventilation is good before checking.
TEST OPERATION
Test Operation preparation:
1. Verify that all piping and connection cables are well connected.
2. Conrm that the values at the gas side the liquid-side are fully open.
3. Connect the power cable to an independent power socket.
4. Install batteries in remote control.
Note: Make sure that the ventilation is good before testing.
Test Operation method:
1. Turn on the power and push the ON/OFF switch button of the remote controller to start the air conditioner.
2. Select COOL, HEAT (not available on cool-only models), SWING and other operation modes with the remote
controller and see if the operation is ok.
Chassis
Outdoor drain elbow
Pressure gauge
Compound meter
-76 cmHg Manifold valve
Handle Hi
Charge hose
Charge hose
Handle Lo
Vacuum pump
Stop valve
(gas valve)
Stop valve
(liquid valve)
57V 11/22
ATTENTION: for maintenance or scrap, please contact authorized service centers. Maintenance by unqualied
person may cause dangers.
APPENDICES
Piping conguration:
PROCEDURE FOR EXTENDING THE PIPING
Note: improper extension of piping is the main cause of refrigerant leaks. Proceed as shown below:
MAINTENANCE NOTES
Connecting pipe diameter Additional refrigerant
Liquid pipe (mm) Gas pipe (mm) (g/m)
Ф6.35 Ф9.52 20
1. Cut the pipe.
Check the length of the pipe based on the
distance between the indoor unit and outdoor
unit.
Cut the required pipe using a pipe cutter.
2. Remove burrs.
Remove burrs with a le, ensuring they do not go
into the pipe.
3. Secure an insulating tube.
Pipe
slanted uneven burred
90°
Pipe cutter
file
pipe
downwards
4. Install a union nut
Remove the union nut on the indoor connecting
pipe and outdoor valve. Install the union nut on
the pipe.
5. Expand the port
Expand the port using a pipe expander:
NB: varies according to diameter
6. Inspection.
Check the quality of the expanded port. If
defective, expand the port again following the
procedure described above.
pipe
union
pipe
pipe
expander
hard
mould
pipe
“A”
smooth surface
equal length
defective expansion
slanted surface
damaged cracked uneven
thickness
Outdoor diameter (mm) A (mm)
Max. Min.
6.35(1/4”) 1.3 0.7
9.52 (3/8“) 1.6 1.0
12.7 (1/2“) 1.8 1.0
15.88 (5/8”) 2.4 2.2
58V 11/22
Here are warnings and safety instructions for the maintenance of systems containing ammable refrigerant (repairs
should only be carried out by specialists).
1. Any person involved in the work or in the interruption of a refrigeration circuit must be equipped with PEF (European
Refrigerators License) as required by the D.P.R. n.146/2018 implementing Regulation (EU) no. 517/2014.
2. Maintenance should only be performed as recommended by the equipment manufacturer. Maintenance and
repairs that require the assistance of other qualied personnel must be performed under the supervision of the
person competent in the use of ammable refrigerants.
Before starting work on systems containing ammable refrigerants, safety checks are required to ensure that the risk of
ignition is minimized.
1. Checks to be carried out on systems that use ammable refrigerants:
the charge must be proportionate to the size of the room in which the units containing refrigerant are installed;
units and ventilation openings must function properly and are not obstructed;
if an indirect refrigerant circuit is used, the secondary circuit must be checked for the presence of refrigerant;
the marking on the equipment must be visible and indelible. Illegible markings and signs must be corrected;
refrigerant piping or components must be installed in a location where they are unlikely to be exposed to any
substance that can corrode the component-containing refrigerant, unless the components are constructed from
materials that are inherently resistant to corrosion or are adequately protected against corrosion.
2. Checks on electrical devices. Repair and maintenance of electrical components must include initial safety checks
and component inspection procedures. If there is a fault that could compromise safety, do not connect the power
supply to the circuit until it is satisfactorily resolved. If the fault cannot be remedied immediately, but operation must
continue, a suitable interim solution must be used. This must be reported to the owner of the equipment so that all
parties are informed.
Initial security checks include:
Check that the capacitors are discharged: this must be done safely to avoid the risk of sparks;
Verify that no electrical components and wiring are exposed while charging, restoring or draining the system;
Check that there is ground continuity.
3. Check for refrigerant leaks. The area should be checked with an appropriate refrigerant detector before and
during work, to ensure that the technician is aware of potentially toxic or ammable atmospheres. Make sure that
the leak detection equipment in use is suitable for use with all applicable refrigerants, i.e. non-sparking, properly
sealed or intrinsically safe.
Check for R32 refrigerant leaks. Note: check for refrigerant leakage in an environment where there are no
potential sources of ignition. No halogen probe (or any other detector that uses an open ame) should be used.
Leak Detection Method: For systems with R32 refrigerant, an electronic leak detection tool is available to detect
and leak detection should not be conducted in a refrigerant environment. Make sure the leak detector does not
become a potential source of ignition and is applicable to the measured refrigerant. The leak detector must be set
for the minimum ammable fuel concentration (percentage) of the refrigerant. Calibrate and adjust to the correct
gas concentration (no more than 25%) with the refrigerant used. The uid used in leak detection is applicable to
most refrigerants. But do not use chloride based solvents to prevent the reaction between chlorine and refrigerants
and corrosion of copper piping. If you suspect a leak, remove all re from the scene or put out the re. If the
location of the leak is to be welded, then all refrigerants must be recovered or isolate all refrigerants away from
the leak site (using the shut-off valve). Before and during soldering, use OFN to purify the entire system.
4. Presence of re extinguisher. If hot work is to be performed on the refrigeration equipment or any associated part,
adequate re ghting equipment must be available. It is necessary to have a dry powder or CO2 extinguisher
adjacent to the charging area.
5. Ventilated area. Make sure the area is outdoors or is adequately ventilated before breaking into the system or
performing any hot work. Continuous ventilation must be present during the period in which the work is being
carried out. Ventilation should safely disperse the released refrigerant and preferably expel it to the atmosphere.
6. Controls on refrigeration equipment. When replacing electrical components, they must be t for purpose and with
WARNINGS FOR THE REFRIGERATION SYSTEM SPECIALIST
59V 11/22
the correct specications. The manufacturer’s maintenance and service guidelines should always be followed. If
in doubt, consult the manufacturer’s technical department for assistance.
7. Repairs on sealed components. During repairs to sealed components, all electrical supplies must be disconnected
from the equipment being worked on before removing the sealed covers, etc. If it is absolutely necessary to have
an electrical power supply to the equipment during maintenance, then a leak detection device must be placed at
the most critical point to warn of a potentially dangerous situation. Particular attention must be paid to the following
to ensure that, by working on the electrical components, the casing is not altered in such a way as to compromise
the level of protection. This includes damage to cables, excessive number of connections, terminals not made to
original specications, damage to gaskets, incorrect assembly of cable glands, etc.
Make sure the appliance is mounted securely.
Ensure that gaskets or sealing materials are not degraded to the point that they no longer serve the purpose
of preventing the entry of ammable atmospheres. Replacement parts must conform to the manufacturer’s
specications.
Note: the use of silicone sealant can inhibit the effectiveness of some types of leak detection equipment. Intrinsically
safe components do not need to be isolated before working on them.
8. Repair of intrinsically safe components. Do not apply permanent inductive or capacitive loads to the circuit
without ensuring that it does not exceed the voltage and current allowed for the equipment in use. The intrinsically
safe components are the only ones that can be worked on in the presence of a ammable atmosphere. The test
equipment must be of the correct evaluation. Replace components only with parts specied by the manufacturer.
Other parts can cause the refrigerant to ignite in the atmosphere due to a leak..
9. Wiring. Verify that the wiring is not subject to wear, corrosion, excessive pressure, vibration, sharp edges, or other
adverse environmental effects. The control must also take into account the effects of aging or continuous vibrations
from sources such as compressors or fans.
10. Deactivation. Before carrying out this procedure, it is essential that the technician is fully familiar with the equipment
and all its details. Good practice is recommended that all refrigerants be recovered safely. Before the task is
performed, a sample of the oil and refrigerant must be taken in case an analysis is required before reuse of the
recovered refrigerant. It is essential that electricity is available before the start of the activity.
A. Become familiar with the equipment and its operation.
B. Electrically isolate the system.
C. Before attempting the procedure, make sure that:
mechanical handling equipment is available, if required, for handling the refrigerant cylinders;
all personal protective equipment is available and used correctly;
the recovery process is supervised at all times by a competent person;
Recovery equipment and cylinders comply with appropriate standards.
D. If possible, drain the refrigerant system.
E. If vacuum is not possible, make a manifold so that the refrigerant can be removed from the various parts of
the system.
F. Make sure the cylinder is placed on the scale before recovery takes place.
G. Start the recovery machine and operate according to the manufacturer’s instructions
H. Do not overll the cylinders. (Not more than 80% by volume of liquid charge).
I. Do not exceed, even temporarily, the maximum working pressure of the cylinder.
J. When the cylinders have been lled correctly and the process is complete, ensure that the cylinders and
equipment are promptly removed from the site and that all isolation valves on the equipment are closed.
K. Recovered refrigerant should not be charged to another refrigeration system unless it has been cleaned and
checked.
11. Labeling. The equipment must be labeled indicating that it has been shut down and drained of refrigerant. The
label must be dated and signed. For appliances containing ammable refrigerants, make sure there are labels on
the appliance indicating that the appliance contains ammable refrigerant..
Recovery
When removing refrigerant from a system, whether for maintenance or decommissioning, It is recommended that all
refrigerants be removed safely. When transferring refrigerant to cylinders, ensure that only appropriate refrigerant
recovery cylinders are used. Make sure the correct number of cylinders are available to maintain full system charge. All
cylinders to be used are designated for the recovered refrigerant and labeled for that refrigerant (i.e. special cylinders
for recovering refrigerant). The cylinders must be complete with pressure relief valve and relative shut-off valves in
good working order. Empty recovery cylinders are evacuated and, if possible, cooled before recovery takes place.
60V 11/22
If compressors or compressor oils need to be removed, make sure they have been evacuated to an acceptable level
to ensure that ammable refrigerant does not remain within the lubricant. The evacuation process must be carried out
before returning the compressor to suppliers. To speed up this process, only electrical heating of the compressor body
must be used. When oil is drained from a system, it must be done safely.
Work procedure.
The work must be carried out according to a controlled procedure in order to minimize the risk of the presence of
ammable gas or vapor during the execution of the work.
1. General work area: all maintenance personnel and others working in the local area should be educated on the
nature of the work being performed. Work in conned spaces must be avoided. The area around the work area
must be sectioned. Ensure that conditions within the area have been secured by the control of ammable material.
2. No ignition sources: No person carrying out work in relation to a refrigeration system involving exposure to piping
must use sources of ignition in a way that creates the risk of re or explosion. All possible sources of ignition,
including cigarette smoke, must be kept sufciently far from the place of installation, repair, removal and disposal,
during which the refrigerant may possibly be released into the surrounding space. Before starting work, the area
around the equipment must be checked to ensure that there is no risk of ammability or ignition hazards. “No
smoking” signs must be displayed.
Removal and evacuation.
When breaking into the refrigerant circuit to make repairs or for any other purpose, conventional procedures must be
used. However, for ammable refrigerants it is important to follow the best procedures as there is a risk of ammability.
The following procedure must be followed:
remove the refrigerant;
purge the circuit with inert gas; evacuate;
purge again with inert gas;
open the circuit by cutting or brazing.
The refrigerant charge must be recovered in the correct recovery cylinders. For appliances containing ammable
refrigerants, the system must be ushed with OFN to make the unit safe. You may need to repeat this process
several times. Compressed air or oxygen must not be used for purging refrigerant systems. For appliances containing
ammable refrigerants, ushing must be achieved by breaking the vacuum in the system with OFN and continuing to
ll until the operating pressure is reached, then discharging to the atmosphere and nally lowering the vacuum. This
process must be repeated until there is no more refrigerant in the system. When the nal OFN charge is used, the
system must be vented to atmospheric pressure to allow the work to be carried out. This operation is absolutely essential
if you want to carry out brazing operations on the pipes. Make sure that the vacuum pump outlet is not close to ignition
sources and that ventilation is available..
Charging procedures.
In addition to conventional charging procedures, the following requirements must be followed:
Make sure that contamination of different refrigerants does not occur when using charging equipment. Hoses or
lines should be as short as possible to minimize the amount of refrigerant they contain.
The cylinders must be kept upright.
Make sure the refrigeration system is grounded before charging the system with refrigerant.
Label the system when charging is complete (if not already done).
Be very careful not to overll the refrigeration system.
Before recharging the system, it must be pressure tested with the appropriate purge gas. The system must undergo a
leak test upon completion of the charge but prior to commissioning. A subsequent leak test
must be carried out before leaving the site.
61V 11/22
www.argoclima.com
Argoclima assumes no responsibility for any errors or inaccuracies in the content of this manual and reserves the right to make to this, at any time
and without notice, any changes deemed appropriate for any technical or commercial need.
REGULATION (EU) No. 517/2014 - F-GAS
The unit contains R32, a uorinated greenhouse gas with global warming potential (GWP) = 675. Do not release R32
into the atmosphere.
GREENSTYLE PLUS 9000 UE - Kg. 0,51 = 0,34 Tonn CO2 equiv.
GREENSTYLE PLUS 12000 UE - Kg. 0,55 = 0,37 Tonn CO2 equiv.
GREENSTYLE PLUS 18000 UE - Kg. 0,80 = 0,540 Tonn CO2 equiv.
GREENSTYLE PLUS 24000 UE - Kg. 1,30 = 0,878 Tonn CO2 equiv.
29

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Argo Greenstyle Plus bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Argo Greenstyle Plus in de taal/talen: Engels als bijlage per email.

De handleiding is 3.07 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

Andere handleiding(en) van Argo Greenstyle Plus

Argo Greenstyle Plus Gebruiksaanwijzing - Italiano - 31 pagina's


Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info