DEHUMIDIFIER
DRY COMPACT 21
OPERATING INSTRUCTIONS
Read the instructions carefully before operating or servicing the dehumidifier.
Observe all the safety instructions; failure to observe the instructions may lead to accidents and/or damage.
Keep these instructions in a safe place for future reference.
EN
14
V 08/19
The Refrigerant R290
To realize the function of the air conditioner unit, a special refrigerant circulates in
the system. The refrigerant is the fluoride R290 = 3 GWP (Global warming
potential). This refrigerant is flammable and inodorous. It can lead to explosions
under certain conditions, however the flammability of this refrigerant is very low and
it can be ignited only by fire.
Compared to other common refrigerants, R290 is a non-polluting refrigerant with no
harm to the ozonosphere and a no effect upon the greenhouse effect. R290 has
very good thermodynamic features which lead to a really high energy efficiency.
The units therefore need less filling.
Warning:
Do not try to accelerate the defrosting process or to clean the appliance in different ways
other than those recommended by the manufacturer. Should repair be necessary, contact
your nearest authorized Argoclima Service Centre. Any repairs carried out by unqualified
personnel may be dangerous. The appliance has to be stored in a room that doesn’t have
any continuously operating ignition sources. (for example: open flames, an operating gas
appliance or an operating electric heater.) Do not pierce or burn.
Appliance has to be installed, operated and stored in a room with a floor area larger than 4
m
2
.
For repairs, strictly follow manufacturer’s instructions only for appliances filled with R290
flammable gas. Be aware that refrigerants do not have any odour.
Appliance filled with flammable gas R290.
Before installing and using the appliance, read the owner’s manual.
Before repairing the appliance, read the service manual.
15
V 08/19
GENERAL OPERATING AND SAFETY INSTRUCTIONS
This appliance is a highly efficient dehumidifier, designed for
domestic use only!
Use this dehumidifier only as outlined in this manual. Any other
use not recommended by the manufacturer may cause fire,
electric shock or malfunctions.
The unit contains refrigerant; keep it vertical at all times.
Once you have opened the unit, keep it vertical to allow the
refrigerant to stabilise and wait two hours before operating it.
Ensure that the required voltage and frequency (220-240V/50Hz)
match the available power source.
This appliance can be used by children aged from 8 years and
above and people with reduced physical, sensory or mental
capabilities or lack of experience and knowledge if they have been
given supervision or instruction concerning use of the appliance in
a safe way and understand the hazards involved.
Children shall not play with the appliance.
Cleaning and user maintenance shall not be made by children
without supervision.
Make sure the plug is inserted fully. Do not use multiple adapters.
Do not touch the plug with wet hands. Make sure the plug is clean.
Children aged between 3 and 8 years must only be able to turn
the appliance on/off, provided that the appliance has been placed
in its normal operating position, that instructions have been given
on how to use the equipment safely, and that its risks have been
understood.
Children aged between 3 and 8 years must not be able to plug in,
adjust, clean or perform any maintenance on the appliance.
Disconnect the mains power when the appliance is not in use
or during cleaning operations. Keeping the appliance plugged
in may cause electric shocks or accidents.
16
V 08/19
To disconnect the appliance, set the switch to OFF and remove
the plug from the socket. Only pull on the plug. Do not pull the
cord.
Do not bend, drag or twist the cord, or apply force to remove it. Do
not operate the unit if its cable or plug are damaged; doing so
can cause fires or electric shock. If the power cord is damaged,
it must be replaced by a service centre.
Do not place heavy objects on top of the appliance.
To prevent water spills, empty the water tank before moving the
appliance.
Do not tilt the dehumidifier onto one side or turn it upside down, as
the water which runs out could damage the appliance.
Do not operate the unit on unstable or sloping surfaces:
water leaks can cause it to malfunction or cause excessive
vibration and running noise.
The dehumidifier must be positioned at least 50 cm away from the
wall or other obstacles, so that the heat can dissipate correctly.
Close all open windows to maximise dehumidification
efficiency.
Do not insert objects or sharp instruments into the air outlet
grille.
Do not cover the air intake and outlet grilles in any way.
WARNING!
In the event of an anomaly, switch the appliance off and unplug
it immediately. Do not dismantle, repair or modify this product
freely. In the event of a malfunction, contact the after-sales
service centre directly.
Do not immerse the power cord, plug or any other part of the
appliance in water or other liquids.
Do not expose the dehumidifier to direct sunlight.
Keep the appliance well away from sources of heat which could
cause plastic parts to become warped.
17
V 08/19
Do not spray insecticides, oils or paints near the appliance; doing
so may damage its plastic parts or start a fire.
Keep flammable gases and oils away from the appliance!
Do not move the appliance while it is operating; doing so can
cause leaks and malfunction.
DESCRIPTION OF PARTS
The following space must be maintained to ensure the operating efficiency of the dehumidifier.
Air inlet
FRONT VIEW REAR VIEW
Multidirectional
wheels
Control panel
Condensate
collection
tank
Cover of
continuous
condensate
draining
connection
Rear panel
Air outlet
Powe
r
cable
18
V 08/19
PRE-OPERATING CHECKS AND OPERATIONS
Before using the appliance, make sure the floater and the condensate collection tank are correctly positioned
1. Remove the tank using both hands, following the direction of the arrow.
2. Pull out the tank using both hands and verify the correct position of the floater.
3. Reposition the tank as shown in the figure below.
OPERATING INSTRUCTIONS
APPLIANCE START-UP
Place the product on a flat and stable heat-resistant surface, at least 1 metre away from flammable or heat-sensitive
materials and 50 cm away from walls or other obstructions.
Make sure the water tank is in the correct position
.
Connect the power cord to a suitable electric socket (220-240V/50Hz).
Turn the appliance on with ON/OFF on the control panel.
The unit emits a “beep” signal and the corresponding LED lights up.
The dehumidifier is designed to operate at ambient temperatures from + 5°C to + 35°C.
If it is operated at low temperatures, ice may form on the evaporator, degrading its operation.
When this happens, the dehumidifier goes into defrost mode. The compressor stops, but the fan continues running.
The defrosting operation may start up and operate for some minutes; during the defrosting operation, the dehumidification
function may intermit: please don’t turn off the switch or pull out the power plug of the dehumidifier.
We recommend not using the dehumidifier in room temperatures lower than 5°C.
Do not remove the tank when the unit is in operation.
If you wish to make continuous draining of condensate, follow the instructions in the dedicated paragraph.
Floater
Correct
Position
Wrong
p
osition
19
V 08/19
OPERATING PRECAUTIONS
The appliance will only start operating if the humidity level in the room is above the set value.
The dehumidifier will continue to operate until the set humidity level has been reached, with the exception of
interruptions caused by a full tank. In this case, empty and reinstall the tank: the dehumidifier will now start running
again.
WARNING:
After each interruption of its operation, at least 3 minutes must pass before the dehumidifier starts up again:
this delay prevents the compressor being damaged.
If, on the other hand, the set humidity percentage is higher than the level currently found in the room, the
dehumidifier will not start.
If, after following the appliance start-up instructions, the dehumidifier does not start and the stand-by (POWER) LED
does not come on, or if the dehumidifier stops for no reason, make sure the plug and power cord are in good working
order. After doing so, wait for 10 minutes and then restart the appliance.
If the dehumidifier still does not start after 10 minutes, or if either the power cord or plug are damaged, switch off the
appliance and contact an after-sales service centre.
WARNING:
When the dehumidifier is running, the compressor produces heat and the appliance emits warm air into the
room. The room temperature will therefore tend to increase. This is completely normal.
TURNING THE DEHUMIDIFIER OFF
To turn the dehumidifier off press the ON/OFF button. This shuts off power to the unit.
Unplug the appliance if you do not intend to use it for some time.
HOW TO ELIMINATE CONDENSATE
The water extracted from the air can be collected in the provided front tank.
When the tank is full, not inserted or not correctly inserted, the FULL TANK led turns on and the unit beeps for about 10
seconds, at the end of which the unit turns off.
To switch off the appliance, press the ON/OFF button and wait a few seconds.
1. Carefully remove the tank using both hands and following the direction of the arrow.
2. Empty the tank.
3. Reposition the tank following the direction of the arrow.
N.B.
Do not use the drain hose when you are collecting condensation in the tank, otherwise water can leak out of the hose.
Collection tank
20
V 08/19
CONTINUOUS CONDENSATE DRAINAGE
The water can be continuously drained when using a PVC hose with an inner diameter of 14 mm (not supplied)
Turn off the appliance and remove the plug before connecting the hose.
Open the small side door, remove the cap and safely connect the hose to the continuous condensate discharge
connection, as shown in the figures below.
The height of the drainage hose must not exceed that of the hole: do not block the drainage hose exit.
When disconnecting the tube, prepare a container to collect the remaining water from the tube.
CONTROL PANEL
Each time the button is pressed, the unit emits an auditory signal.
LED TIMER
LED VELOCITA’ DI
VENTILAZIONE
BASSA-MEDIA-
ALTA
LED TANICA
PIENA
LED PULIZIA
FILTRO
LED
MODALITÀ
CONTINUOUS
LED POWER
21
V 08/19
BUTTONS & LEDS
1. ON/OFF BUTTON - Press this button to turn the dehumidifier on and off.
2. FILTER BUTTON
- After 250 hours of operation, the FILTER RESET led turns on to indicate that it is time to clean
the filter. Take the filter out and clean it. Then press the FILTER button.
3. 1. FILTER BUTTON - After 250 hours of operation, the FILTER RESET led turns on to indicate that it is time to
clean the filter. Take the filter out and clean it. Then press the FILTER button.
NOTE: if Co (Continuous) mode is selected, the unit will continue to operate at maximum dehumidification capacity, so it
is advisable to dispose of the condensate with continuous drainage.
4. RELATIVE HUMIDITY ADJUSTER BUTTONS
(-/+) -The humidity can be set from 35% to 80% in 5% steps with
the + and - buttons, or you can set the appliance to continuous drain (CO) – maximum dehumidification.
NOTE: if Co (Continuous) mode is selected, the unit will continue to operate at maximum dehumidification
capacity, so it is advisable to dispose of the condensate with continuous drainage.
5. DISPLAY
– it shows the relative humidity setting.
6. FAN SPEED BUTTON - Press these buttons to set the fan speed (Low / Medium / High).
7. TIMER ON/OFF BUTTON - Delayed on/off button (2 or 4 or 6 hour delay), selected according to this circular
sequence (2 - 4 - 6 hours - off).
LED On: unit is working
LED Cont: unit is running in Continuous mode.
LED Filter: filter needs to be cleaned.
LED TIMER: the timer is set (2 or 4 or 6 hours).
LED HIGH/MED/LOW FAN SPEED : it shows the set fan speed: High, Medium or Low.
LED Full: When the tank is full, the LED Full comes on and the appliance stops running. A 10 second beep sounds.
Remove the tank and empty it (as indicated in "HOW TO ELIMINATE CONDENSATION"), the restore it; the dehumidifier
will start running again.
DEFROST: the dehumidifier is designed to operate at ambient temperatures from + 5°C to + 35°C.
If it is operated at low temperatures, ice may form on the evaporator, degrading its operation.
When this happens, the dehumidifier goes into defrost mode. The compressor stops, but the fan continues running.
We recommend not using the dehumidifier in room temperatures lower than 5°C.
MEMORY FUNCTION: the dehumidifier starts up again after a power failure keeping last settings.
22
V 08/19
CLEANING AND MAINTENANCE
MAINTENANCE OF THE HUMIDIFIER’S EXTERIOR SURFACE
Warning
Always pull the dehumidifier's plug out of the power socket before cleaning it, to prevent electric
shock and malfunction.
Warning
Do not wet the appliance or immerse it in water, otherwise electric shocks may occur.
Use a damp and soft cloth to clean the exterior surface of the dehumidifier.
Do not use solvents, petrol, xylene, talcum powder or brushes to clean the unit: these may damage
the surface or colour of the casing.
CLEANING THE WATER TANK
We advise removing the tank once every few weeks to prevent mould and bacteria forming on it. Fill the tank with clean
water a small amount of detergent; swill the water around in it, then it out and rinse it thoroughly.
CLEANING THE AIR FILTER
The filter is designed to remove dust or dirt from the air.
If the filter is clogged by dust, electricity consumption will be higher than
normal.
Cleaning instructions:
1. Remove the tank.
2. Remove the filter by pulling down the flap complete extraction.
Clean the filter washing it with warm soapy water.
DO NOT USE ALCOHOL, BENZENE OR OTHER AGGRESSIVE
PRODUCTS TO CLEAN THE FILTER.
Leave the filter to dry naturally, then reposition it in its slot.
3. Reinsert the filter pushing it upwards until you hear a sound.
4. Reposition the tank.
Do not use the dehumidifier without the filter as dust may affect the efficiency
of the evaporator, resulting in higher energy consumption.
Air filter
23
V 08/19
TROUBLESHOOTING
PROBLEM
POTENTIAL CAUSE
SOLUTION
The dehumidifier is not working.
It is not possible to adjust the settings.
The temperature is above 32 ° C or below 5
°C.
The internal tank is full.
The tank is not positioned correctly.
The power plug is not inserted correctly
Empty the tank
Position the tank correctly
Correctly connect the plug
The noise suddenly increases while
running
The compressor has just started.
There is a power connection problem.
The unit is placed on an uneven surface.
Position the unit on an even and
stable surface.
Reduced dehumidification effect The room temperature is too low.
The set humidity level is inadequate.
The filter is full of dust.
The doors and windows are open.
If the unit is running with a temperature
between 5 and 15 °C, the unit will pause for
automatic defrosting. The compressor will
pause for short periods. After the defrost, the
unit will resume normal operation.
Reduce the humidity level.
Clean the filter.
Close any doors and windows.
Remove objects that obstruct the
inflow and outflow of air.
At first, the air might have a musty
smell
Due to the temperature difference of the heat
exchanger, the air might have a strange smell
at first.
There is water in the tank even when
using the hose for continuous
condensation drainage
Check the drainage connections.
The drainage hose is not connected properly.
Connect the hose correctly.
Remove the drainage hose and
replace it.
The ON/OFF LED does not turn on
when the power is connected
There is no power or the plug is not inserted
correctly.
Check the electrical power supply.
Make sure that the electric circuit
and plug are not damaged.
Make sure that the cable is not
damaged.
The dehumidifier stops working during
dehumidifying process.
Whether the room temperature is too high or
too low and out of the working scope of the
dehumidifier.
The dehumidifier may start
automatically when the room
temperature returns to the working
scope.
The humidity of the room can’t reduce. The room area is too big, which is over its
application scope.
The door and windows of the room aren’t
closed.
The machine unit is operated with a kerosene
heater which releases steam.
There is water in the tank. Since each machine unit has taken operation
test before leaving the factory, some water
remains on the evaporator flows to the water
tank.
The FULL indicator LED is on. When the water tank is full, the FULL indicator
led is on for reminding.
24
V 08/19
REGULATION (EU) N. 517/2014 - F-GAS
DRY COMPACT 21
The unit contains R290, a natural greenhouse gas with global warming potential (GWP) = 3 - Kg. 0.08 = 0.00024
Tons CO
2
equiv.
Do not release R290 into the atmosphere.
INFORMATION FOR THE CORRECT DISPOSAL OF THE PRODUCT IN ACCORDANCE WITH EUROPEAN
DIRECTIVE 2012/19/EU
This appliance may not be scrapped with domestic waste at the end of its life cycle. We call your attention to the
crucial role played by the consumer in the re-use, recycling and other forms of recovery of such waste.
The appliance must be scrapped by a sorted waste disposal centre or by returning it to the retailer (no charge is
levied for this service), when you purchase a new equivalent appliance.
Sorted disposal of electric and electronic equipment prevents the negative effects on the environment and human
health resulting from improper scrapping, and also allows the materials from which it is made to be recovered and
recycled, with significant savings in terms of energy and resources.
The so
r
ted disposal requirement is indicated by the crossed waste bin label affixed to the appliance.
www.argoclima.com
10

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Argo DRY COMPACT 21 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Argo DRY COMPACT 21 in de taal/talen: Engels als bijlage per email.

De handleiding is 0,99 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

Andere handleiding(en) van Argo DRY COMPACT 21

Argo DRY COMPACT 21 Gebruiksaanwijzing - Deutsch - 12 pagina's

Argo DRY COMPACT 21 Gebruiksaanwijzing - Français - 12 pagina's


Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info