28 Arada Farringdon 12
OPERATING INSTRUCTIONS
AIR INLET CONTROL
The Arada Farringdon 12kw stove air inlet control.
The primary air inlet provides the main air supply to the
fuel and the air wash system through the control slider
located under fire door on the Left side. Placed fully to
the LEFT is Low air, and to the RIGHT is High air.
The air wash system, so called because its pre-heated
high speed air, washes across the inner face of the door
glass, keeping it clear. This also provides an over
draught to the fuel bed, for combustion of the wood fuel.
PRIMARY AIR
Air enters the appliance through the control at the
bottom of the fire door. The Arada Farringdon has a
single control slider sliding left to right.
See Fig. 10. & 11. below
Note:
The air supply does not fully close intentionally
Fully Open Position (Lever In RH Position) Minimum Closed Position (Lever In LH Position)
The exact position of the air control will vary
according to installation factors and some
experimentation will be required to acquire the
optimum position for burning
The primary air control (Left) should be used to
vary the burn rate. 3/4 open will produce
approximately 12 kwh for a 3.8kg load (1 hour
burn time to refuelling) dependant on fuel quality
and moisture content.
Operation at continuously low burn rates will
increase the production of tar and other residues
building up in the flue and chimney and should be
avoided.
Fig. 10. Fig. 11.