General Safety
Keep children and animals away from air conditioning units.
Never leave them alone in a room where the units in use.
This equipment should only be used by a competent person who
has read and understood these instructions.
Never operate this equipment if you are ill, feeling tired or under the
influence of alcohol or drugs.
Keep the Air Conditioning vents clear of all obstructions.
Never put anything on top of the unit or block the air outlets.
Make sure equipment is switched off and unplugged after use
Never leave switched on or unattended.
Do not use the unit where sunlight is shining directly onto it.
Check condition of equipment before use. If unit is showing signs of
damage contact your supplier immediately.
Electrical Safety
This unit requires a 230 volt electrical supply. It plugs into a
standard BS1363 domestic socket.
Always inspect plugs and leads for damage before plugging into
the supply - DO NOT USE IF ANY DAMAGE IS FOUND
Ensure cables are run as not to cause a hazard.
If an extension lead is used, ensure it is of the correct standard ,
and fully uncoiled when being used.
Do not lay electrical cables in wet / damp areas.
Do not move equipment whilst operating.
Do not pull equipment by its cable.
It is recommended that electrical equipment is used via a suitable RCD.
WARNING!
As standard this unit requires a 13 amp fused electrical supply rated at
230v 1ph 50hz.
The unit will operate from a standard 13A wall socket. The size of any
extension cable that may be 2-5mm2 minimum up to a maximum
length of 10 metres. For longer lengths 4mm2 cable must be used.
If the cable is on a ‘cable drum’ then ensure that it is completely
unwound; serious complications will occur otherwise.
Air Cooled Units
The system comprises, a room unit fitted with either a fixed or flexible
ducting system as specified by the customer. Condensate is collected,
either in the units internal tank and emptied by the user or pumped
using an optional condensate disposal unit (fig. 1).
Air Flow
The angled air outlets at the top of the room unit are fitted with air grilles
that allow the angle of air outlet to be adjusted vertically and horizontally
and, in conjunction with the fan speed control switch, the air velocity
and direction can be carefully set up to obtain maximum coverage of
the area being cooled without causing drafts. Care should be taken
to avoid outlet air being obstructed as this will cause the air to ‘eddy’
around the unit resulting in recirculation and short/inaccurate cycling of
the machine. Ideally, cold air should be directed to create a ‘blanket’ all
across the ceiling area allowing natural convection to drop the air over
the whole area at very low velocity. An alternative top panel with twin 7”
ducts is available.
Siting of Zephyr
Ideally, the room unit should be positioned equidistant along he shortest
wall in the room blowing down the length of the room. Of there is more
than one unit in the same area, then they would normally be positioned
side by side, and equidistant along the long wall, all pointing in the
same direction. Sometimes it may be necessary to position units
around the perimeter of an area but, in this case, great care should
be taken t avoid one unit blowing cold air straight into another which
will adversely affect the machine operation. Good and correct air flow
is, perhaps, the single most important aspect of satisfactory applying
portable air conditioners. If in doubt seek the advice of your supplier.
Exhaust Tubes Air Cooled Unit
The exhaust tube(s) must carry the air to an area external to that being
cooled, preferably in the outside atmosphere (fig. 1).
Click www.andrews-sykes.com
or Call Us Free 0800 211 611
Zephyr ET
Portable Air Conditioning
Operating Instructions
& Safety Guide
Operation Instructions
The control panel on the room unit is illustrated below
Revolve thermostat knob fully CLOCKWISE to the number ‘8’ position
Plug in the room unit mains cable, and switch on the electricity, red
mains light will illuminate.
Select ‘Fan Only’ with the mode switch. The fan will start.
Select ‘Fan Speed’ with the fan speed switch, high or low
depending on air velocity required.
Select ‘Cooling’ with the mode switch, and revolve the thermostat
knob fully ANTI-CLOCKWISE to he number ‘1’ position. After a
delay of 10 mins the green ‘Cooling’ light will illuminate and the
machine will proceed to cool the air.
Monitor the room temperature and when it has reduced to the desired
level, very slowly revolve the thermostat knob back, clockwise until the
greenCoolinglight goes out. The room unit will now control the room
temperature cooling automatically at this setting.
Routine Maintenance
The airlter must be kept clean, never allow to become choked with
dust or dirt. If allowed to do so, the performance of the unit will become
impaired, resulting in loss of air flow, freezing up the evaporator coil and
possible component damage.
Accessing the Filter
On machines fitted with a hinged lower panel, open panel. The filter is
located on front of the evaporator. A second filter is fitted to the rear panel
on all air cooled machines.
On machines without a hinged front panel, to access the filter, lift out the
return air grille on the front face of the unit. On refitting the filter ensure that
it is correctly positioned covering the whole face of the grille.
The filter (see Fig 4) can be washed in warm, soapy water, rinsed and
shaken dry before replacement. Frequency of cleaning depends upon
Operating Instructions - Zephyr ET
Click www.andrews-sykes.com or Call Us Free 0800 211 611
application and can only be determined by the user. However, you should
never allow more than two months to elapse between cleaning. The
probable life of the filter will be about one year and spares are available
from the supplier of the unit itself. Failure to have filter tted during
operation will cause serious damage (see fig. 4 / 5).
Problem Likely Cause Solution
No cooling Amber ‘ATTENTION’
light illuminated. High
level condensate trip.
Condensate pump not reducing water level.
Kink in condensate tube between room
unit and external heat exchanger? Leak
inside room unit. Pump filter inside room unit
blocked. Condensate tube frozen.
No cooling Amber ‘ATTENTION’
light illuminated. Bottle
fitted switch trip.
On machines without a removable
bottle, ensure link fitted to terminal
block. On machines with , ensure bottle
fitted correctly.
No cooling Amber ‘CONTAINER
FULL’ light illuminated.
High level condensate
trip.
On machines without a removable
bottle, as above. On machines with a
bottle, remove container and replace
correctly. To empty the condensate
bottle, pull forward the lower front panel,
(Fig 2).
The front cover will come forward, giving
access to the container, (Fig 3).
Empty the container, and carefully
replace.
Ensure the drain pipe is fitted into the
container.
The filter is located on the rear of the
unit, ensure it is kept clean.
Fitting the hot air exhaust
Fig.2
Fig.3 Fig.4
Fig.5
Fig.1
1

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Andrews Zephyr ET bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Andrews Zephyr ET in de taal/talen: Engels als bijlage per email.

De handleiding is 0,24 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info