The A&D blood pressure monitor is one of the most advanced
monitors available and is designed for ease of use and accuracy.
This device will facilitate your daily blood pressure regimen.
We recommend that you read through this manual carefully before
using the device for the first time.
2.Preliminary Remarks
This device conforms to the European Directive 93/42 EEC for
Medical Products. This is made evident by the
mark of
conformity. (0123: The reference number to the involved notified
body)
The device is designed for use on adults only, not newborns or
infants.
Environment for use. The device is for use in the home healthcare
environment.
This device is designed to measure blood pressure and pulse rate
of people for diagnosis.
3.Precautions
Precision components are used in the construction of this device.
Extremes in temperature, humidity, direct sunlight, shock or dust
should be avoided.
Clean the device and cuff with a dry, soft cloth or a cloth dampened with
water and a neutral detergent. Never use alcohol, benzene, thinner or
other harsh chemicals to clean the device or cuff.
Avoid tightly folding the cuff or storing the hose tightly twisted for
long periods, as such treatment may shorten the life of the
components.
Take care to avoid accidental strangulation of babies or infants
with the hose.
Do not twist the air hose during measurement. This may cause
injury due to continuous cuff pressure.
The device and cuff are not water resistant. Prevent rain, sweat
and water from soiling the device and cuff.
Measurements may be distorted if the device is used close to
televisions, microwave ovens, X-ray or other devices with strong
electrical fields.
Wireless communication devices, such as home networking
devices, mobile phones, cordless phones and their base stations,
walkie-talkies can affect this blood pressure monitor.
Therefore, a minimum distance of 11 feet should be kept from
such devices.
When reusing the device, confirm that the device is clean.
Used equipment, parts and batteries are not treated as ordinary
household waste, and must be disposed of according to the
applicable local regulations.
Do not modify the device. It may cause accidents or damage to
the device.
To measure blood pressure, the arm must be squeezed by the
cuff hard enough to temporarily stop blood flow through the
artery. This may cause pain, numbness or a temporary red mark
to the arm. This condition will appear especially when
measurement is repeated successively. Any pain, numbness, or
red marks will disappear with time.
Measuring blood pressure too frequently may cause harm due to
blood flow interference. Check that the operation of the device
does not result in prolonged impairment of blood circulation,
when using the device repeatedly.
Clinical testing has not been conducted on pregnant women. Do
not use the device on pregnant women.
If you have had a mastectomy, please consult a doctor before
using the device.
Do not let children use the device by themselves and do not
leave the device within the reach of children.
There are small parts that may cause a choking hazard if
swallowed by mistake by infants.
Do not touch the batteries, the patient and the DC jack at the
same time. That may result in electrical shock.
Contraindications
The following are precautions for proper use of the device.
Do not apply the cuff on an arm with another medical electrical
equipment attached. The equipment may not function properly.
People who have a severe circulatory deficit in the arm must
consult a doctor before using the device, to avoid medical
problems.
Do not self-diagnose the measurement results and start
treatment by yourself. Always consult your doctor for evaluation
of the results and treatment.
Do not apply the cuff on an arm with an unhealed wound.
Do not apply the cuff on an arm receiving an intravenous drip or
blood transfusion. It may cause injury or accidents.
Do not use the device where flammable gases such as
anesthetic gases are present. It may cause an explosion.
Do not use the device in highly concentrated oxygen
environments, such as a high-pressure oxygen chamber or an
oxygen tent. It may cause a fire or explosion.
4.Parts Identification
Display
5.Symbols
Symbols that appear on the display
Symbols Function / Meaning Recommended Action
A
ppears while measurement
is in progress. It blinks when
the pulse is detected.
Measurement is in
progress. Remain as still
as possible.
I.H.B. appears when an
irregular heartbeat is detected.
It may light when a very slight
vibration like shivering or
shaking is detected.
Previous measurements
stored in memory.
FULL BATTERY
The battery power indicator
during measurement.
LOW BATTERY
The battery power is low when
it blinks.
Replace all batteries with
new ones when the mark
blinks.
A
ir Socke
t
Air Connector Plug
A
ir Hose
Proper fit range
Measurement in progres
s
Inflation complete
Inflation in progres
s
Cuff
1 to 2 cm
Artery position mark
Secure the fabric fastener
Air hose
Index
and Proper fit range
At heart level
Refer to the section
"7.1 Normal Measurement"
Press the_START_button
The desired pressure
Inflation in progress
Press and hold the
_START_button
Release the_START_
button to stop inflation
Press and hold the
_START_button
The mark blinks.
Data is cleared.
Release the
button
Select "" to
clear data.
Turns off automatically
5 seconds
Step 1
Step 3
Step 4
Step 2
Press and hold the
_START_button
Release the button
mark
Average data
Data number
Stored Data
To next data
Turns off automatically
No data
WHO Classification Indicator
Severe hypertension
Moderate hypertension
Mild hypertension
High normal
Normal
Optimal
Exhausts remaining air
automatically
At heart level
Press the_START_button
All of the display segments
Zero display
Starts inflation
Pressurizing
Measurement in progress
Systolic pressure
Diastolic pressure
WHO classification
Pulse rate
Turn off with the
_START_button
Pressurizing Releasing air
Display
Air Hose
Arm Cuff
START
Button
Index
Air Socket
Proper fit range
Artery position mark
A
ir Connector Plug
Battery Compartment
Battery Cove
r
MEMORY
Systolic Pressure
Diastolic Pressure
Pulse Rate
Heart Mark
Battery Indicator
I.H.B. symbol
(Irregular Heartbeat symbol)
Pressure Bar Indicator and
WHO Classification Indicator
Note: Model UA-611 doesn't have the DC jack for AC adapter.
The DC jack is located on the rear of the model,UA-651 only. The
AC adapter is an optional accessory.(sold separately)
Model UA-651 only
DC jack
AC adapter plug
AC adapter Plug
DC
j
ack
Model UA-651 only
Do not roll up shirtsleeve tightly
Hulp nodig? Stel uw vraag in het forum
Misbruik melden
Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.
Product:
Spelregels forum
Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:
lees eerst de handleiding door;
controleer of uw vraag al eerder door iemand anders is gesteld;
probeer uw vraag zo duidelijk mogelijk te stellen;
heeft u een probleem en al geprobeerd om dit op te lossen, vermeld dit erbij aub;
heeft u een oplossing gekregen van een bezoeker dan horen wij dat graag in dit forum;
wilt u een reactie geven op een vraag of antwoord, gebruik dan niet dit formulier maar klik op de knop 'reageer op deze vraag';
uw vraag wordt direct op de website gezet; vermijd daarom persoonlijke gegevens in te vullen;
Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.
Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.
Abonneren
Abonneer u voor het ontvangen van emails voor uw AnD UA-611 bij:
nieuwe vragen en antwoorden
nieuwe handleidingen
U ontvangt een email met instructies om u voor één of beide opties in te schrijven.
Ontvang uw handleiding per email
Vul uw emailadres in en ontvang de handleiding van AnD UA-611 in de taal/talen: Engels als bijlage per email.
De handleiding is 0,25 mb groot.
U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.
Stel vragen via chat aan uw handleiding
Stel uw vraag over deze PDF
Uw handleiding is per email verstuurd. Controleer uw email
Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.
Er is een email naar u verstuurd om uw inschrijving definitief te maken.
Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken
U heeft geen emailadres opgegeven
Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.
Uw vraag is op deze pagina toegevoegd
Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.