Cleaning and Maintenance
6 3
A Word About the AM-45
Always disconnect the unit from the electrical outlet prior to cleaning or
servicing the unit!
Note that the servicing intervals mentioned in this section are based on air purifier use of 12 hours
per day in a normal household environment. If your use of the air purifier differs from that described
above, then you can adjust the servicing intervals accordingly.
1. Clean the outside of the AM-45 and the area around the air purifier with a soft damp cloth
once every 2 weeks. If you are not using the Ionizer, then this interval can be increased to
once a month.
2. Access to the AM-45 filters and serviceable components is by removing the rear cover.
To remove the rear cover, push the button above the rear cover while pulling back on the rear
cover. The rear cover will pivot away from the main unit and then it can be lifted up and away.
The rear cover is reinstalled by fitting the projection at the bottom of the rear cover into the
slot at the back of the main unit and then closing the top of the rear cover until it snaps
into place.
3. The Pre-Filter is removed from the rear cover, by sliding it out the upper edge of the rear
cover. The Pre-Filter is reinstalled by sliding it back in the slot from where it was removed.
The Pre-Filter should be washed in warm soapy water or with a water spray once a month.
Make sure that the Pre-Filter is completely dry before reinstalling it.
4. Inside the rear cover facing the front of the unit are 6 ionizing needles that work together with
the Aluminum Mesh Filter to make the Electrostatic Filter. The needles are inside protective
cylinders and the needles should be cleaned with a brush once a month.
5. The Aluminum Mesh Filter is visible looking at the open back side of the main unit. The
Aluminum Mesh Filter frame holds both the Aluminum Mesh Filter and the Granulated Active
Carbon Filter. Remove the Aluminum Mesh Filter frame by lifting the tab above the filter and
then by pulling backwards towards the user on the upper part of the filter. The Granulated
Active Carbon Filter is removed from the Aluminum Mesh Filter frame, by sliding it out the
upper edge of the Aluminum Mesh Filter frame. Note that this needs to be done before
washing the Aluminum Mesh Filter. The Granulated Active Carbon Filter is reinstalled by
sliding it back in the slot from where it was removed. The Aluminum Mesh Filter frame is
reinstalled by fitting the bottom of the filter frame into its place at the back of the main unit
and then closing the top of the filter frame until it snaps into place.
a. The Aluminum Mesh Filter should be washed in warm soapy water once a month.
Make sure that the Aluminum Mesh Filter is completely dry before sliding the
Granulated Active Carbon Filter into its place in the Aluminum Mesh Filter frame
and reinstalling the filter pair into its place at the back of the main unit.
b. The Granulated Active Carbon Filter should be replaced once a year.
If the Granulated Active Carbon Filter is dusty, it can be cleaned gently with a vacuum cleaner.
c. While the Aluminum Mesh Filter frame is out of the unit, the interior of the unit
should be wiped with a soft dry cloth.
continued on page 7
This manual has been prepared to acquaint you with the proper installation, operation and maintenance
of your AM-45 Air Purifier. We urge you to read this publication carefully and to follow the
recommendations to help assure the most enjoyable and trouble free operation of your Amcor unit.
When it comes to service, remember that Amcor knows its product best.
Please do not attempt to open, repair and/or clean any of the internal parts of the AM-45 Air Purifier
yourself. This could result in loss of the warranty.
We would like to take this opportunity to thank you for choosing an Amcor product, and to assure
you of our continuing interest in your comfort, pleasure and health.
Safety
The AM-45 Air Purifier is safe. It is listed by ETL and it has been designed with special attention
to safety. However, as with other electrical appliances, use it with care.
Do not clean the AM-45 Air Purifier by spraying it or immersing it in water.
Do not insert any object into the openings of the AM-45 Air Purifier.
Disconnect the product from the electrical outlet before cleaning the unit or any of its components.
Do not connect the AM-45 Air Purifier to an electric outlet using an extension cord.
If there is no accessible outlet, a licensed electrician should install one.
WHEN NOT IN USE STORE OUT OF REACH OF CHILDREN!
Warning
Any service, other than regular cleaning or filter replacement should be performed by an authorized
service representative. Failure to do so could result in loss of warranty.
To reduce the risk of electric shock, this equipment has a polarized plug (one blade is wider
than the other). This plug will fit in a polarized outlet only one way. If the plug does not fit fully
in the outlet, reverse the plug. If it still does not fit, contact qualified personnel to install the
proper outlet.
Do not alter the plug in any way.
If the supply cord becomes damaged, it must be replaced by the manufacturer or its service agent
or similarly qualified person in order to avoid a hazard.
7

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Amcor AM-45 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Amcor AM-45 in de taal/talen: Engels als bijlage per email.

De handleiding is 0,45 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info