Rear Panel Overview
1 Mains input Use the IEC lead with moulded
mains plug suitable for your local voltage. The
protection fuse rating is marked on the rear panel.
The on/off switch is positioned on the rear panel
to prevent accidental operation.
2 Network port RJ45 socket for connection to
an Ethernet network or PC using UTP CAT5 cable.
This port is recommended for configuring the
system with iDR software. The MDI/X switch
selects network or direct to PC operation. The link
LED lights when communication is established.
The TX LED lights when data is communicated.
Note: The RS232, MIDI, SysNet and PL-Anet
control ports are not all available at the same time.
A combination of two is selected using iDR
System Manager. The associated active LED
lights when the port is available.
3 RS232 (MODEM) port This is used for
connection to a modem so that the unit can be
interrogated by a remote PC over a standard
telephone line. It can also be used for system
configuration using iDR System Manager software
but the faster network port is recommended.
Pressing the front panel switch selects either the
front or rear RS232 port.
4 MIDI port Standard opto-isolated MIDI port
with IN, THRU and OUT connectors.
5 SysNet port An RS232 serial port for
communication with third party remote controllers
running the Allen & Heath SysNet protocol.
6 PL-Anet port An RS485 serial port for
communication with a network of Allen & Heath
PL wall plates and remote controllers using CAT5
STP cable.
7 DR-Link port RJ45 socket for control of iDR
audio and logic expander units using CAT5 STP
cable. IN and OUT ports are provided on the
expander units so that the control can be daisy
chained through a system with more than one
expander.
8 Audio expander ports RJ45 sockets for
communicating 8 channel digital audio between
the iDR-8 and its expanders using CAT5 STP
cable. Two cables are required between the
expander and iDR-8, one for the audio, the other
for DR-Link control.
9 Mic/Line inputs Balanced XLR inputs for
microphone and line level sources. Adding the
iDR-in expands the iDR-8 to 16 inputs.
10 Audio outputs Balanced XLR line level
outputs with maximum +18dBu level. Adding the
iDR-out expands the iDR-8 to 16 outputs.
11 Monitor inputs and outputs Balanced TRS
jacks for L and R monitor inputs and outputs.
These provide a line level version of the front
panel stereo headphones output and can daisy
chain through multiple iDR units.
12 Switch closure inputs These are provided
on the iDR-switch. They can be hard wired from
remote wall plate and controller switches and
relays.
13 Open collector logic outputs These are
provided on the iDR-switch. They can be used to
control LEDs, lamps, relays and other devices.
14 Earth terminals These are provided to earth
(ground) the switch and logic output cable
shields.
Use null-modem cable to connect to PC com port
CAUTION: RISK OF ELECTRIC SHOCK. DO NOT OPEN.
FOR CONTINUED PROTECTION AGAINST RISK OF FIRE REPLACE FUSE WITH SAME TYPE AND RATING.
ATTENTION: RE MPLACER LE FUSIBLE AVEC UN DES MEMES CARACTERISTIQUES.
THIS APPARATUS MUST BE EARTHED.
WARNING
47-63Hz ~ 90W MAX
100 - 240V~
active
RS232 (MODEM)
Complies with UL6500, CSA-E65, EN60065
MONITOR OUT
LINKTX
Refer to user guide for port selection details
FUSE: T1.6AL
AVIS: RISQUE DE CHOC ELECTRIQUE - NE PAS OUVRIR.
SERIAL NUMBER
Made in the UK by ALLEN&HEATH LIMITED
MONITOR IN
DIGITAL EXPANDER
R
PL-ANET
DR-LINK
LR
AUDIO OUTAUDIO IN
THRU
active
MDI/X
NETWORK
MIDI OUT
active
MIDI IN
active
SYSNET PORT
L
OUT 8 OUT 7 OUT 5
LINE OUTPUTS
OUT 6 OUT 4
IN 8 IN 7 IN 5
MIC/LINE INPUTS
IN 6 IN 4
OUT 3 OUT 2 OUT 1
IN 3 IN 2 IN 1
Made in the UK by ALLEN&HEATH LIMITED
AUDIO OUT
CAUTION: RISK OF ELECTRIC SHOCK. DO NOT OPEN.
FOR CONTINUED PROTECTION AGAINST RISK OF FIRE REPLACE FUSE WITH SAME TYPE AND RATING.
ATTENTION: REMPLACER LE FUSIBLE AVEC UN DES MEMES CARACTERISTIQUES.
47-63Hz ~ 25W MAX
100 - 240V~
THIS APPARATUS MUST BE EARTHED.
WARNING
SERIAL NUMBER
AVIS: RISQUE DE CHOC ELECTRIQUE - NE PAS OUVRIR.
FUSE: T500mAL
next
OUT
DR-LINK
previous
IN
IN 10
Complies with UL6500, CSA-E65, EN60065
IN 16 IN 15
MIC/LINE INPUTS
IN 14 IN 13 IN 11IN 12
IN 9
AUDIO IN
Made in the UK by ALLEN&HEATH LIMITEDCAUTION: RISK OF ELECTRIC SHOCK. DO NOT OPEN.
FOR CONTINUED PROTECTION AGAINST RISK OF FIRE REPLACE FUSE WITH SAME TYPE AND RATING.
ATTENTION: REMPLACER LE FUSIBLE AVEC UN DES MEMES CARACTERISTIQUES.
THIS APPARATUS MUST BE EARTHED.
WARNING
47-63Hz ~ 25W MAX
100 - 240V~
SERIAL NUMBER
FUSE: T500mAL
AVIS: RISQUE DE CHOC ELECTRIQUE - NE PAS OUVRIR.
next
OUT DR-LINK
previous
IN
OUT 10
Complies with UL6500, CSA-E65, EN60065
OUT 16 OUT 15
LINE OUTPUTS
OUT 14 OUT 13 OUT 11OUT 12 OUT 9
VG
G 4321 G5678G 1211109 G13141516G 20191817 G21222324
SWITCH INPUTS
LOGIC OUTPUTS
123
+-
4
VGVGVG +-+-+-
567
+-
8
+-+-+-
910
+-+-+-+-
11
1214
+-+-+-+-
1516 13
switch
G
opto
+10V
2K2
opto
+
-
V
G
+10V DC max total 500mA
open collector
+24V DC, 200mA max
+10V
FUSE: T500mAL
WARNING
THIS APPARATUS MUST BE EARTHED.
ATTENTION: REMPLACER LE FUSIBLE AVEC UN DES MEMES CARACTERISTIQUES.
FOR CONTINUED PROTECTION AGAINST RISK OF FIRE REPLACE FUSE WITH SAME TYPE AND RATING.
100 - 240V~
47-63Hz ~ 15W MAX
CAUTION: RISK OF ELECTRIC SHOCK. DO NOT OPEN. AVIS: RISQUE DE CHOC ELECTRIQUE - NE PAS OUVR IR. Made in the UK by ALLEN&HEATH LIMITED Complies with UL6500, CSA-E65, EN60065
OUT INDR-LINK
next previous
TO AVOID DAMAGE ONLY CONNECT
CAUTION 20V DC
COMPATIBLE REMO TE CONTROL
EQUIPMENT TO THE PL-ANET PORT.
DIGITAL EXPANDER
DIGITAL EXPANDER
9

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Allen-Heath iDR-8 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Allen-Heath iDR-8 in de taal/talen: Engels als bijlage per email.

De handleiding is 6,46 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info