Mains Power and Earthing
Connecting Mains Power Read the SAFETY INSTRUCTIONS printed at the front of this
user guide and on the rear panel. The power supply is wired for the local voltage required. Check that
the correct mains lead with moulded plug has been supplied with your console, and that the marked
voltage matches your local supply. Ensure that the IEC mains plug is pressed fully into the rear panel
socket before switching on.
To avoid any unexpected audible clicks or thumps
turn connected power amplifiers down or off before
switching the console or any other signal equipment on or
off. The built-in amplifiers include an automatic turn on delay
for this purpose.
Switching On Press the rear panel ON/OFF switch in. The
front panel blue power LED lights. You should hear the
speaker relays switching in after a second or two. This avoids
audible thumps while the circuits stabilise. The front panel SPK
OFF indicators light while the speakers are isolated. You may
also hear air movement as the internal fans start up. The
meters and several other LED indicators may pulse briefly.
This is quite normal.
Switching Off Release the rear panel ON/OFF switch. The
relays switch off instantly to protect the speakers from any
switch off thumps.
Earthing The connection to earth (ground) in an audio system is important for two reasons:
SAFETY to protect the operator from high voltage electric shock, and AUDIO PERFORMANCE to shield
the audio from interference.
For safety it is important that all equipment earths are connected to mains earth so that exposed metal
parts are prevented from carrying high voltage which can injure or even kill the operator. It is
recommended that the system engineer check the continuity of the safety earth from all points in the
system including microphone and instrument metal, equipment cases, rack frames, and so on.
The same earth is also used to shield audio cables from external interference such as the hum fields
associated with power transformers, lighting dimmer buzz, and computer radiation. Problems arise
when the signal sees more than one path to mains earth. An ‘earth loop’ (ground loop) results causing
current to flow between the different earth paths. This condition is usually detected as a mains
frequency audible hum or buzz.
To ensure safe and trouble-free operation we recommend the following:
Have your mains system checked by a qualified electrician If the supply earthing is solid to
start with you are less likely to experience problems.
Do not remove the earth connection from the console mains plug The console chassis is
connected to mains earth through the power cable to ensure your safety. Audio 0V is connected to
the console chassis internally.
Deal with ground loops Should you experience hum or buzz caused by earth loops, check first
that each piece of equipment has its own separate path to earth. If so, operate earth lift switches
on connected equipment in accordance with the instruction manuals. Alternatively, disconnect the
cable screen at the destination end only. This breaks the offending loop while still maintaining the
signal shielding down the length of the cable.
Use low impedance sources such as microphones and line level equipment rated at 200 ohms or
less to reduce susceptibility to interference. For high impedance instruments use DI (direct inject)
boxes such as those readily available from most music equipment suppliers. The console outputs
are designed to operate at very low impedance to minimise interference problems.
Use balanced connections for the microphone inputs and main outputs as these provide
further immunity by cancelling out interference that may be picked up on long cable runs. Refer to
the cable diagrams for details on how to connect balanced and unbalanced equipment.
Route cables to avoid interference To avoid interference pickup keep audio cables away from
mains power units and cables, thyristor dimmer units or computer equipment. Where this cannot
be avoided, cross the cables at right angles to minimise interference.
Use good quality cables and connectors and check for correct wiring and reliable solder joints.
Use the correct cable type. Allow sufficient cable loop to prevent damage through stretching.
If you are not sure ... Contact your service agent or local Allen & Heath dealer for advice.
CAUTION
RISK OF ELECTRIC SHOCK
8 OHMS4 OHMS
CONSTANT POWER SWITCH
DO NOT OPEN
SERIAL NUMBER
FUSE
0
V AC ~ 47- 63 Hz
1600W MAX
MAINS INPUT
CAUTION: FOR CONTINUED PROTECTION AGAINST RISK OF FIRE
ATTENTION: REMPLACER LE FUSIBLE AVEC UN DES MEMES CARACTERISTI
Q
SEE OPERATING MANUAL BEFORE USING.
NO USER SERVICEABLE PARTS INSIDE.
DO NOT OBSTRUCT VENTILATION OPENINGS.
RISK OF HAZARDOUS ENERGY! MAKE PROPER SPEAKER CON
N
THIS APPARATUS MUST BE EARTHED BY THE POWER CORD.
DO NOT EXPOSE THIS APPARATUS TO RAIN OR MOISTURE.
AVIS: RISQUE DE CHOC ELECTRIQUE - NE PAS OUVRIR.
WARNING: TO REDUCE THE RISK OF ELECTRIC SHOCK
100-240V T10A L
ENGINEERED IN ENGLAND BY ALLEN & HEATH Ltd.
REPLACE
F
ON/OFF
I
11

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Allen-Heath PA-CP Series bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Allen-Heath PA-CP Series in de taal/talen: Engels als bijlage per email.

De handleiding is 3,84 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info