ML5000 User Guide 21
A MONO INPUT and EQ. The input preamp
matches microphone or line level signals to the
console. The sweepable high pass filter removes
unwanted low frequency sounds below the selected
frequency. The channel insert is post filter, pre EQ.
A swept frequency 4 band equaliser provides
shelving high and low bands with adjustable shelf
frequency, and fully parametric high and low mid
bands with adjustable centre frequency and Q. The
filter and EQ can be independently switched in or
out.
B GRP/AUX SENDS. This section provides
controls for the group routing and auxiliary sends.
Controls 1-8 function according to the setting of the
mode switches in the master section F . These
configure group routing switches and independent
post-fade aux sends for FOH (front-of-house)
application, or pre/post switchable sends for stage
monitor application. Controls 9-16 can be
configured as mono or stereo pre/post aux sends.
C MAIN MIX SENDS. A single switch routes the
channel signal to the main L, R and C outputs. The
balance between the three outputs is determined by
the LCRplus pan and blend controls. Pan can also
be switched in or out of the group routing for stereo
or mono groups.
D INPUT FADERS. Includes the channel fader,
mute, signal meter and PAFL monitoring. The 8
VCA group assignments are displayed. VCA and
mute group editing and channel safe selection is
performed using the mute switch with green
safe/edit indicator below.
E STEREO INPUT and EQ. The input preamp
accepts two stereo sources with independent
control of each. This allows selection of either or
mixing together both sources. A fixed frequency 4
band equaliser provides shelving high and low
bands and two bell mid bands. The EQ can be
switched in or out.
F GRP/AUX 1-8 MASTERS. These are the
fader masters for channel sends 1-8, configurable
using mode switches as fixed level groups or as
variable level pre or post-fade auxes. The output
can be routed to the main mix through LCRplus
controls to create sub groups. LED meters display
the pre-fade mix levels.
G AUX 9-16 MASTERS. These are the fader
masters for channel sends 9-16.
H ROTARY AUX 1-8 MASTERS. These are the
rotary masters for channel post-fade aux sends 1-8.
They provide the independent effects sends when
the fader masters are configured as groups. They
still function when the fader masters are configured
as pre/post auxes but would not normally be
required.
I MAIN MIX FADERS. Provides separate master
faders and mutes for the main L, R and C outputs.
A mode switch configures the C output as the
engineers wedge monitor feed for the stage monitor
application.
J MATRIX. This section provides all the controls
for the 8 matrix outputs, including the source and
master rotaries.
K VCA GROUPS. These are the VCA group
master faders, mutes and PAFL monitor switches.
Channels are assigned to the groups using the edit
key. The normal fader operating level is marked ‘0’.
L MUTE GROUPS. These are the master keys
that mute all channels assigned to the group.
Channels are assigned using the edit key.
M SNAPSHOT MEMORIES. Provides the
controls to store, recall and preview the 128
onboard memories, and edit channel safes. Mute
settings and/or VCA assignments can be disabled
from the snapshots.
N SOLO-IN-PLACE. Pressed with the shift key
this puts the console into SIP mode ready to solo
any channel when its mute key is pressed.
O HEADPHONES / MONITOR. Provides source
selection and independent control of the
headphones and local monitor outputs.
P PAFL CONTROL. This section controls how
the intelligent PAFL system functions and provides
the clear all key.
Q OSC/NOISE GENERATOR. Enables and
selects a 1kHz tone or pink noise which can be
routed to any output for line up or system testing.
R INTERCOM. The console talkback mic and
headphones can be interfaced to a ClearCom
compatible intercom system so eliminating the need
for a separate intercom headset.
S TALKBACK. Pressing the talk switch routes
the talkback mic to any output with its TB enable
switch selected. The mic input is duplicated on the
rear panel for plugging in hand held microphones.
T GRP/AUX 1-8 METERS. These moving coil
VU meters display the grp/aux 1-8 outputs.
U LRC/PAFL METERS. The main L,R and C
outputs are simultaneously displayed on both VU
and LED bar meters. These switch to display any
PFL or AFL when selected. The display is mono or
mono + stereo depending on source. The large call
lamp lights to warn when the intercom is signalled.
V AUX 9-16 / MTX 1-8 METERS. These meters
display either the aux 9-16 outputs or matrix 1-8
levels according to the setting of the meter select
switch near section O .
21

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Allen-Heath ML-5000 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Allen-Heath ML-5000 in de taal/talen: Engels als bijlage per email.

De handleiding is 3,46 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info