Model No: AC-S24CK_S24HK
Version 1.0
M
M
M
o
o
o
d
d
d
e
e
e
l
l
l
G
G
G
r
r
r
o
o
o
u
u
u
p
p
p
:
:
:
A
A
A
C
C
C
-
-
-
S
S
S
2
2
2
4
4
4
Model :
AC-S24CK
AC-S24HK
3
Model No: AC-S24CK_S24HK
Version 1.0
Content
Feature …………………………………..……………………………………………….. 4
Specifications ……………………………………………………………………………. 5
Operating range …………………………………………………………………………. 5
Remote control …………………………………………………………………………...7
Refrigeration cycle ………………………………………………………………………. 10
Operation details ……………………………………………………………………… 12
Installation ……………………………………………………………………………….. 22
2-way, 3-way valve ……………………………………………………………………… 33
Trouble shooting ……………………………………………………………………… 41
Exploded drawing …………………………………………………………………… …. 49
Part list …………………………………………………………………………………… 52
4
Model No: AC-S24CK_S24HK
Version 1.0
CHAPTER 1: FEATURES
MODE
DESCRIPTION
COOLING Cools, dehumidifies and filters the room air. Maintains desired room temperature.
HEATING Heats and filters the room air. Maintains desired room temperature.
SMART
Operates the appliance at COOLING, HEATING or DRY mode, maintaining desired
temperature dependent upon the room temperature.
DRY
Dehumidifies and softly cools the room air. This mode is advisable to be used when the
room temperature is rather cool but the humidity is rather high.
FAN ONLY Re-circulates and filters the room air. Maintains constant air movement in the room.
SLEEP
The SLEEP mode will be canceled after being set for 8 hours. The set temperature will
be increased 0.5
o
per hour during the first two hours in COOLING or DRY and
decreased 1
o
per hour in the first three hours in HEATING.
AUTO FAN
The appliance automatically selects the indoor fan speed in accordance to the room
temperature. At the start, the appliance operates at high fan speed. As the room
temperature gets closer to the set temperature, the fan switches to a lower speed for
quieter operation.
FAN SPEED
HIGH
MEDIUM
LOW
1. The appliance can set at different indoor fan motor speed by pressing the FAN
SPEED button on the remote controller.
2. When this symbol is being displayed on the LCD of the remote controller, the signal is
transmitting from the remote controller to the air conditioner.
TEMP. SET
UP
DOWN
Press DOWN button once, the set temperature is decreased by 1
o
.
Press UP button once, the set temperature is increased by 1
o
.
TIMER
Automatically switches the appliance ON at preset time intervals, ensuring a comfortable
environment before you return home, or switches OFF the appliance automatically
when
you sleep without wasting electricity.
Auto -restart
When the power supply restores after its failure, the machine will start to work
automatically with the previous setting parameters.
SUPER
Strong cooling when you just come into your room and wan
t to cool the room as soon as
possible.
5
Model No: AC-S24CK_S24HK
Version 1.0
CHAPTER 2: SPECIFICATIONS
(SEE APPENDIX A)
CHAPTER 3: OPERATING RANGE
1. TEMPERATURE RANGE FOR T1 CLIMATE AIR CONDITIONER
l The preset temperature of the appliance ranges from 18
o
C to 32
o
C.
l The ambient temperature of the cooling only air conditioner ranges from 18
o
C to
43
o
C.
l The ambient temperature of the heat pump ranges from –7
o
C to 43
o
C.
l The rated cooling operation test condition is as following.
Indoor DB/WB temperature: 27
o
C /19
o
C
outdoor DB/WB temperature: 35
o
C /24
o
C
l The rated heating operation test condition is as following.
l indoor DB/WB temperature: 20
o
C /Max.15
o
C
l outdoor DB/WB temperature: 7
o
C /6
o
C
2. TEMPERATURE RANGE FOR T3 CLIMATE AIR CONDITIONER
l The preset temperature of the appliance ranges from 18
o
C to 32
o
C .
l The ambient temperature of the cooling only air conditioner ranges from 21
o
C to
52
o
C.
l The rated cooling operation test condition is as following.
Indoor DB/WB temperature: 27
o
C /19
o
C
outdoor DB/WB temperature: 35
o
C /24
o
C
6
Model No: AC-S24CK_S24HK
Version 1.0
Indoor unit
Pipe length is
15 meters Max
Outdoor unit
e
l
e
v
a
t
i
o
n
s
h
o
u
l
d
b
e
l
e
s
s
t
h
a
n
5
m
Indoor unit
e
l
e
v
a
t
i
o
n
s
h
o
u
l
d
b
e
l
e
s
s
t
h
a
n
5
m
Curled tube for
returning water
Outdoor unit
3. REFRIGERANT PIPING
l The maximum length of the connecting refrigerant piping between indoor unit
and outdoor unit is 15m and the maximum elevation difference between indoor
and outdoor units are 5m.
l If the refrigerant piping is longer than 7m,additional refrigerant charge 20g/m for
below 1/2 inch gas pipe and 30g/m for below 5/8 or 3/4 inch gas pipe is advis-
able.
l Outside diameter of the refrigerant piping is as following.
Models
OD of liquid pipe
(small pipe)
OD of gas pipe
(large pipe)
7K, 9K (COOLING ONLY & HEAT PUMP 6mm or 1/4 inch 10mm or 3/8 inch
12K, 18K,24K ( COOLING ONLY &
HEAT PUMP)
6mm or 1/4 inch 12mm or 1/2 inch
7
Model No: AC -S24CK_S24HK
Version 1.0
CHAPTER 4: REMOTE CONTROLLER
The remote controller transmits signals to the system.
1. ON/OFF BUTTON
l The appliance will be started when it is energized or will be stopped when it is in
operation, if you press this button.
2. MODE BUTTON
l Used to select the type of operation mode.
COOLING mode
9
5
3
8
4
2
7
6
1
8
Model No: AC -S24CK_S24HK
Version 1.0
DRY mode
FAN ONLY mode
HEATING mode
3. FAN SPEED BUTTON
l Used to select the indoor fan motor speed.
Automatic fan speed
High fan speed
Medium fan speed
Low fan speed
4.TEMPERATURE SETTING BUTTON
l Used to adjust the preset room temperature.
l Used to adjust time in TIMER mode.
5. SWING BUTTON
l Press to adjust airflow direction.
6. SMART BUTTON
l Used to enter fuzzy logic operation directly, regardless of the unit is on or off.
7. TIMER SET/CANCEL BUTTON
l Used to set or cancel the timer operation.
8. SLEEP BUTTON
l Used to set or cancel SLEEP mode operation during COOLING, HEATING, DRY
or SMART mode operation.
9. SUPER BUTTON
l Used to start or stop the fast cooling.
(Fast cooling operates at high fan speed with 18
o
C setting temperature
automatically)
The indication symbols on LCD:
9
Model No: AC -S24CK_S24HK
Version 1.0
Indication symbols on LCD:
Signal transmit.
Smart indicator
Dry indicator
Fan only indicator
Sleep indicator
Heating indicator
Cooling indicator
Super indicator
High fan speed
Medium fan speed
Low fan speed
Auto fan speed
10
Model No: AC -S24CK_S24HK
Version 1.0
CHAPTER 5: REFRIGERATION CYCLE
1. Cooling only appliance
ÖÆÀäϵͳͼ
Indoor unit
evaporator
liquid side
gas side
3-way valve
Outdoor unit
accumulator
compressor
condenser
capillary
11
Model No: AC -S24CK_S24HK
Version 1.0
2. Heat pump
¼¼Êõ²ÎÊý:
Indoor unit
evaporator
liquid side
gas side
3-way valve
2-way valve
check valve
Outdoor unit
accumulator
compressor
condenser
reverse valve
capillary
heating cooling
defrost
Flow of refrigerant
12
Model No: AC -S24CK_S24HK
Version 1.0
CHAPTER 6: OPERATION DETAILS
1. SAFETY CONTROL
l 3 minutes delay for compressor
The compressor is ceased for 3 minutes to balance the pressure in the refrigeration
cycle in order to protect the compressor.
l 59 seconds delay for reversing valve
The 4-way reversing valve delay for 59 seconds to prevent the refrigerant abnormal
noise when the HEATING operation is OFF or switched to other operation modes.
l Over-current control
The compressor will be switched OFF when it is over-current for 5 seconds, and
when the current is normal and the compressor has been stopped for 3 minutes , the
compressor will be turned ON.
l Freeze preventive control
When the indoor pipe temperature falls below –1
o
C during COOLING or DRY
operation for 3 minutes, the compressor and outdoor fan motor turn OFF with buzzer
3 beeps . When the indoor pipe temperature recovers to 5
o
C and the compressor has
been stopped for 3 minutes, the compressor and outdoor fan motor will be turned
ON.
l Overheating protection system
When overloading occurs during the heating operation, this system controls the
outdoor fan motor and compressor according to the indoor pipe temperature to
prevent the overloading of the compressor and restrain the rise in high pressure.
When the indoor pipe temperature exceeds 53
o
C, the outdoor fan motor will be
turned OFF, and when the indoor pipe temperature falls below 49
o
C, the outdoor fan
motor recovers to ON. When the indoor pipe temperature exceeds 63
o
C, the
appliance will be turned OFF with 4 beeps of buzzer and cannot recover
automatically.
13
Model No: AC -S24CK_S24HK
Version 1.0
2. AIR FLOW DIRECTION CONTROL
l This function is to swing the louver up and down automatically and to set it at a
desired position.
l The procedure is as following.
F Press the ON/OFF button to operate the appliance. The louver will swing
automatically to the default position.
F Press the SWING button to swing the louver up and down automatically.
F Repress the SWING button to stop the louver at a desired position.
l The louver is controlled by a step motor. The different default position of different
modes is as following:
F The louver can swing from 0° to 110°.
F The louver closes at 0°.
F The louver swings from 25° to 65° with an automatic setting point of 45° during
COOLING operation.
F The louver swings from 10° to 30° with an automatic setting point of 30° during
DRY operation.
F The louver swings from 45° to 98° with an automatic setting point of 85° during
HEATING operation.
F The louver swings from 45° to 98° with an automatic setting point of 85° during
FAN only operation.
3. COOLING MODE OPERATION
l When the COOLING mode operation is selected without setting temperature, the
appliance will set the preset temperature at 26
o
C automatically with the AUTO
FAN speed.
l When selecting the COOLING mode operation, the appliance will operate ac-
cording to the setting by the remote controller and the operation diagram is as
following:
14
Model No: AC -S24CK_S24HK
Version 1.0
4. DRY MODE OPERATION
l The appliance starts as COOLING operation. If 3 minutes elapses after starting,
the appliance will sense the intake air temperature and minus 1.5
o
C as the
setting temperature.
l During DRY operation, the compressor ON when temperature is the setting
temperature plus 1
o
C. The compressor OFF when temperature is the setting
temperature minus 1
o
C. The setting temperature can only be adjusted by 2
o
C
up and down.
l When the appliance operates at DRY mode, the indoor motor speed is LOW.
5. HEATING MODE OPERATION (ONLY AVAILABLE FOR HEAT PUMP)
l The appliance will operate at the setting by the remote controller and the opera-
ROOM TEMP.
SET TEMP.+1¡æ
(COMP.ON)
SET TEMP.-1¡æ
(COMP. OFF)
Indoor fan motor
speed
Compressor
Outdoor fan motor
set
speed
low
speed
set
speed
low
speed
set
speed
ON OFF ON OFF ON
ON OFF ON OFF ON
More than
3 mins
More than
3 mins
set set
15
Model No: AC -S24CK_S24HK
Version 1.0
SET TEMP.+4.5¡æ
(COMP. OFF)
SET TEMP.+2.5¡æ
(COMP. ON)
ROOM TEMP.
More than
3 mins
30 secs
30 secs
Indoor fan motor speed
*
*
set
speed
UL OFF
set
speed
OFF
UL
Compressor ON OFF ON OFF
Outdoor fan motor ON OFF ON OFF
* The indoor fan motor is controlled by Cold Air Preventive System.
A
B
A
B
*
*
1
o
tion diagram is shown as following.
l The indoor fan motor is controlled by Cold Air Preventive System.
6. COLD AIR PREVENTIVE SYSTEM (ONLY AVAILABLE FOR HEAT PUMP)
l This system is intended to prevent cold air from being discharged during
HEATING operation.
l The indoor fan motor speed will be controlled as following. (for7K, 9K, 12K, 18K
and 22K heat pump)
Set Temp +1
o
(Comp Off)
Set Temp -1
(Comp On)
16
Model No: AC -S24CK_S24HK
Version 1.0
l The indoor fan motor speed will be controlled as following. (for 24K heat pump)
7. SMART MODE OPERATION
l When SMART air conditioning is selected, the operation mode and preset
temperature are set automatically according to the room temperature at starting
operation.
l The operation procedure of cooling only is as following.
Intake air temperature at
operation start
Over 26
o
C Below 26
o
C
Preset temperature
26
o
C
Intake air temperature minus
1.5
o
C
Operation mode COOLING DRY
*The initial mode will be continued and independent upon the room temperature
changing.
l The operation procedure of heat pump is as following.
17
Model No: AC -S24CK_S24HK
Version 1.0
Intake air temperature at
operation start
Over 26
o
C 21
o
C ~ 26
o
C Below 21
o
C
Preset temperature
26
o
C
Intake air temperature at
operation start
22
o
C
Operation mode COOLING DRY HEATING
The initial mode will be continued and independent upon the room temperature
changing.
l If initial mode is selected, that mode is continued, independent upon the
temperature changing.
l The indoor fan motor speed is automatically determined by Auto Fan Speed. If
you are not satisfied with the auto fan speed, you can adjust the fan speed by
pressing the FAN BUTTON.
8. AUTO FAN SPEED
l When the Auto Fan Speed is selected in COOLING or HEATING operation, the
indoor fan motor speed is automatically controlled by the intake air temperature
and the preset temperature.
l The operation procedure of COOLING is as following.
Set temp.+3¡æ
Intake air temp.
Indoor fan
motor speed
Low
High
Indoor pipe temperature risesIndoor pipe temperature rises Indoor pipe temperature falls
Set temp.+1¡æ
Intake air temp.
Set temp.
Set temp.+2¡æ
High
Medium
Indoor fan
motor speed
Set temp.+1¡æ
Medium
Low
18
Model No: AC -S24CK_S24HK
Version 1.0
l The operation procedure of HEATING is as following.
9. INDOOR FAN SPEED CONTROL
l Auto Fan Speed control
When set to Auto Fan Speed, the indoor fan motor speed is controlled by the
difference between the intake air temperature and the preset temperature. The more
the difference, the higher the indoor fan motor speed. Auto Fan Speed is only
available for COOLING and HEATING modes.
l Manual fan speed control
Basic fan motor speed adjustment (3 setting, LOW, MEDIUM and HIGH) can be
conducted by using the Fan Speed Selection button on the remote controller.
l The indoor fan speed in different modes is shown as following.
Fan Speed High(H) Medium(M) Low(L) Stop
COOLING Manual OK OK OK N/A
Automatic OK OK OK N/A
HEATING Manual OK OK OK N/A
Automatic OK OK OK N/A
Cold Air Preventive OK OK OK OK
DRY N/A N/A OK N/A
FAN ONLY OK OK OK N/A
Indoor pipe temperature risesIndoor pipe temperature rises Indoor pipe temperature falls
Medium Low
Indoor fan
motor speed
Intake air temp.
Set temp.-2¡æ
Set temp.
Intake air temp.
Set temp.-1¡æ
Set temp.-3¡æ
Low
High
HighMedium
Indoor fan
motor speed
19
Model No: AC -S24CK_S24HK
Version 1.0
10. EMERGENT START
l If you lose the remote controller or it is out of work, you can also operate the
appliance by pressing the EMERGENT BUTTON on the indoor unit for an
emergent start.
l The operation mode is SMART if an emergent start is presented when the
appliance is connected to the power at first time. If the appliance is in stand by,
the operation mode will restore the last time setting when you press the
EMERGENT BUTTON.
11. AUTORESTART FUNCTION
When the unit is connected to power, pressing the EMERGENT BOTTON for over
5 seconds;
if the unit without auto restart function, it will be of the function of auto restart
after the buzzer 1 beeps;
if the unit with auto restart function, it will discharge the auto restart function
after the buzzer 1 beeps.
12. DEFROST
l The defrost timer (integrating the operation time of compressor)counts time by
microprocessor during HEATING operation.
l 50 minutes later after starting HEATING operation or after defrost, when the
outdoor pipe temperature falls to –8
o
C , the defrosting is started. When the
outdoor pipe temperature exceeds 8
o
C or the defrosting time reaches 10
minutes, the defrosting is ended.
l During the defrosting operation, the red LED indicator on the indoor unit of the
appliance flickers.
l In the defrost operation, firstly the compressor and the outdoor fan motor are
turned OFF. 59 seconds later the reversing valve is turned OFF. 60 seconds
later the compressor is turned ON.
l The maximum defrost time is 10 minutes.
l In the end of defrosting, the compressor is turned OFF, 59 seconds later the
reversing valve is turned ON. 60 seconds later the compressor and outdoor fan
motor are turned ON and starting HEATING operation.
l During the defrost operation, the indoor fan motor is controlled by Cold Air
20
Model No: AC -S24CK_S24HK
Version 1.0
Preventive System.
l The HEATING and defrosting operation is alternated as following.
l The defrosting procedure is shown as following.
Switch ON
Heating
Min 50 mins
Heating
Min 50 mins
Heating
Min 50 mins
Defrosting
Max 10 mins
21
Model No: AC -S24CK_S24HK
Version 1.0
13. TIMER MODE OPERATION
l The setting time ranges from 0.5 hour to 24 hours.
l OFF-TIMER can be set when the appliance is in operation, and it will be
switched OFF when the preset time is achieved.
l ON-TIMER can be set when the appliance is in suspension, and it will be
switched ON when the preset time is achieved.
l Pressing TIMER button once, the last setting time display on the LCD of remote
controller. You can adjust the setting time by pressing the TEMPERATURE
SETTING BUTTON. Pressing the TIMER button again, the timer mode is se-
lected and the yellow LED indicator on the indoor unit lights up.
l The TIMER mode can be cancelled by pressing the TIMER button again on the
remote controller.
14. SLEEP MODE OPERATION
l The SLEEP mode can only be set during COOLING,DRY,SMART or HEATING
operation.
l An energy conservation operation will be achieved if selecting SLEEP mode
combined with OFF-TIMER. The operation will be turned OFF after the preset
time. The maximum preset time of SLEEP mode is 8 hours(default time).
l When selecting the COOLING or DRY operation with SLEEP mode, the
operation diagram is as following. The setting temperature will be raised by
0.5
o
C per hour in the first two hours after the starting. The operation will stop
after 8 hours.
l When selecting HEATING operation with SLEEP mode, the setting temperature
will be decreased by 3
o
C during successive 3 hours later. The operation will
Set temp.
Max 8 hours
2 hours
1 hour
0.5¡æ
0.5¡æ
SLEEP START
SLEEP STOP
22
Model No: AC -S24CK_S24HK
Version 1.0
stop in 8 hours. The operation diagram is as following.
CHAPTER 7: INSTALLATION
Notice: There is detailed information about installation in the OPERATING AND
INSTALLATION INSTRUCTIONS MANUAL. The same information is not repeated in
this TECHNICIAN SERVICE MANUAL.
1. SELECT THE BEST LOCATION
l Indoor unit
F There should not be any heat source or steam near the unit.
F There should not be any obstacles to prevent the air circulation.
F A place where air circulated in the room will be good.
F A place being drained can be easily obtained.
F A place where noise prevention is taken into consideration.
F Do not install the unit near the door way.
F Ensure the spaces from the wall, ceiling, fence or other obstacles.
l Outdoor unit
F If an awning is built over the unit to prevent direct sunlight or rain exposure, be
careful that heat radiation from the condenser is not restricted.
F There should not be any animals or plants which could be affected by air dis-
charged.
F Ensure the spaces from the wall, ceiling, fence or other obstacles.
F A place where noise does not annoy your neighbors.
Max 8 hours
1 hour
2 hours
3 hours
1¡æ
2¡æ
3¡æ
Sleep start
Sleep stop
23
Model No: AC -S24CK_S24HK
Version 1.0
2. DRILL THE PIPING HOLE WITH 70mm DIAMETER HOLE-CORE DRILL
l Line according to the arrows marked on the lower left and right side of the in-
stallation plate.
l The meeting point of the extended line is the center of the hole.
l Drill the piping hole at either the right or the left and the hole should be slightly
slant to the outdoor side.
3. PIPING AND DRAINAGE OF INDOOR UNIT
l Preparation of piping
1) Cut the pipes and the cable
F Use the accessory piping kit or the pipes purchased locally.
F Measure the distance between the indoor and the outdoor units.
F Cut the pipes a little longer than measured distance.
24
Model No: AC -S24CK_S24HK
Version 1.0
F Cut the cable a 1.5m longer than the pipe length.
25
Model No: AC -S24CK_S24HK
Version 1.0
2) Remove burrs
F Remove burrs from cut edges of pipes.
F Turn the pipe end down to avoid the metal powder entering the pipe.
F Caution: If the burrs are not removed, they may cause a gas leakage.
26
Model No: AC -S24CK_S24HK
Version 1.0
3) Flaring the pipes
F Insert the flare nuts, mounted on the connection ports of both indoor and outdoor
units, onto the copper pipes. Some refrigerant gas may leak, when the flare nuts
are removed from the indoor unit, as some gas is charged to prevent the inside of
the pipe from rusting.
F Fit the copper pipe end into the bar of flare tool about 0~0.5mm higher .
F Flare the pipe ends.
4) Tape the flaring portion to protect it from the dust or damages.
l Indoor unit installation
F Hook the indoor unit onto the upper portion of installation plate.(Engage the two
hooks of the rear top of the indoor unit with the upper edge of the installation
plate.)
F Ensure the hooks are properly seated on the installation plate by moving it in left
and right.
l Connecting the piping to the indoor unit
F Align the center of the piping and sufficiently tighten flare nut with fingers.
F Finally, tighten the flare nut with torque wrench until the wrench clicks.
F Wrench tightening the flare nut torque wrench, ensure the direction for tightening
follows the arrows on the wrench.
27
Model No: AC -S24CK_S24HK
Version 1.0
Pipe Size Torque
Liquid Side(φ6 or 1/4 inch) 1.8 kg.m
Liquid Side (φ10 or 3/8 inch) 3.5 kg.m
Liquid Side(φ12 or 1/2 inch) 5.5 kg.m
Gas Side (φ10 or 3/8 inch) 3.5 kg.m
Gas Side(φ12 or 1/2 inch) 5.5 kg.m
Gas Side(φ16 or 5/8 inch) 7.5 kg.m
Gas Side(φ19 or 3/4 inch) 10.0 kg.m
l Wrap the insulation material around the connecting portion.
4. CONNECTING PIPINGS AND THE CABLE TO OUTDOOR UNIT
l Connecting the piping to outdoor unit
F Align the center of the piping and sufficiently tighten the flare nut with fingers.
F Finally, tighten the flare nut with torque wrench until the wrench clicks.
28
Model No: AC -S24CK_S24HK
Version 1.0
F When tightening the flare nut with torque wrench, ensure the direction for tight-
ening follows the arrows on the wrench.
Pipe Size Torque
Liquid Side(φ6 or 1/4 inch) 1.8 kg.m
Liquid Side (φ10 or 3/8 inch) 3.5 kg.m
Liquid Side(φ12 or 1/2 inch) 5.5 kg.m
Gas Side (φ10 or 3/8 inch) 3.5 kg.m
Gas Side(φ12 or 1/2 inch) 5.5 kg.m
Gas Side(φ16 or 5/8 inch) 7.5 kg.m
Gas Side(φ19 or 3/4 inch) 10.0 kg.m
l Connecting the cable to the outdoor unit as shown in OPERATING AND
INSTALLATION INSTRUCTIONS MANUAL.
29
Model No: AC -S24CK_S24HK
Version 1.0
5. CHECKING THE DRAINAGE AND CONNECTING THE CABLE TO INDOOR
UNIT
l Checking the drainage
1) Remove the grille from the cabinet
F Set the up-and-down air direction louver to open position(horizontally) by finger
pressure.
F Remove the screw caps and the securing screws.
F To remove the grille, pull the lower left and right side of the grille toward you
(slightly titled) and lift it straight upward(Two tabs on the top inside edge of the
grille are clear of their slots).
2) Check the drainage
F Pour glass of water on the evaporator.
F Ensure if water flows from drainage hose of indoor unit.
l Form the piping
F Wrap the connecting portion of indoor unit with the insulation material and se-
cure it with two plastic bands (for the right piping).
30
Model No: AC-S24CK_S24HK
Version 1.0
F If you may connect an additional drainage hose, the end of the drainage-outlet
should keep distance from the ground.(Do not dip it into water, and fix it on the
wall to avoid swinging in the wind.)
l In case of the outdoor unit is installed below position of the indoor unit.
F Tape the piping, drainage hose and connecting cable from down to up.
F Form the piping gathered by taping along the exterior wall and fix it onto the wall
by saddle or equivalent.
31
Model No: AC-S24CK_S24HK
Version 1.0
l In case of the outdoor unit is installed upper position of the indoor unit.
F Tape the piping and connecting cable from down to up.
F Form the piping gathered by taping along the exterior wall and the trap is re-
quired to prevent water from entering into the room.
F Fix the piping onto the wall by saddle or equivalent.
l Connecting the cable to the indoor unit as shown in the OPERATING AND
INSTALLATION INSTRUCTIONS MANUAL.
6. AIR PURING OF THE PIPINGS AND INDOOR UNIT
l Air purging preparation
F Remove the caps from the 2-way and 3-way valves.
F Remove the service-port cap from the 3-way valve.
F To open the valve, turn the valve spindle of 2-way valve counter-clockwise ap-
proximate 90°° and hold it there for 5 seconds, then close it.
F Caution: Do not leak the gas in the air during air purging.
32
Model No: AC -S24CK_S24HK
Version 1.0
l Leakage checking
F Check a gas-leakage of the connection portion of the piping.
F If there is no leakage found, open 2-way again, turn the valve spindle coun-
ter-clockwise until it stops.
F If there is leakage found, re-tighten the connecting portion with wrench. If the
leakage persists, locate a leakage and repair it until leakage ceases.
l Air purging
F To purge the air, push the pin on the service port of 3-way valve for three sec-
onds with a hexagonal wrench, wait for one minute.
F Repeat the operation three times.
No leakage found
Leakage found
Open 2-
way valve again, turn the
valve spindle counter-
clockwise
until it stops
Re-tighten the connecting portion with
wrench
Leakage ceases
Leakage
persists
Locate a repair leak
Purge the air, push the pin on the service port of the 3-way valve for three
seconds with a hexagonal wrench, wait for one minute. Repeat the operation fo
r
three times.
33
Model No: AC -S24CK_S24HK
Version 1.0
l Set the both 2-way and 3-way valves to open position with the hexagonal wrench
for the unit operation.
l Checking a gas leakage for the left piping
F connect the manifold gauge to the service port of 3-way valve. Measure the
pressure.
F Keep it for 5~10 minutes. Ensure if the pressure indicated on the gauge is as
same as that of measured at the first time.
l Follow the result of right side piping.
l The additional gas for air purging has been charged in the outdoor unit. However,
if the flare connections have not been done correctly and gas leaks a gas cylin-
der and the charge set will be needed.
34
Model No: AC -S24CK_S24HK
Version 1.0
CHAPTER 8: 2-WAY, 3-WAY VALVE
2-way Valve(Liquid Side) 3-way Valve(Gas Side)
Works Spindle position Spindle position Service port
Shipping
Closed
(with valve cap)
Closed
(with valve cap)
Closed
(with cap)
Air purging
(Installation)
Open
(counter-clockwise)
Closed
(clockwise)
Open
(push-pin)
Operation
Open
(with valve cap)
Open
(with valve cap)
Closed
(with cap)
Pumping down
(Transferring)
Closed
(clockwise)
Open
(counter-clockwis
e)
Open
(connected manifold
gauge)
Evacuation
(Servicing)
Open Open
Open
(with charging
cylinder)
Gas charging
(Servicing)
Open Open
Open
(with charging
cylinder)
Pressure check
(Servicing)
Open Open
Open
(with charging
cylinder)
Gas releasing
(Servicing)
Open Open
Open
(with charging
cylinder)
35
Model No: AC -S24CK_S24HK
Version 1.0
1. AIR PURGING (INSTALLATION)
l Required tools: hexagonal wrench, adjustable wrench, torque wrenches, wrench
to hold the joints, and gas leak detector.
l The additional gas for air purging has been charged in the outdoor unit. However,
if the flare connections have not been done correctly and gas leaks, a gas cylin-
der and the charge set will be needed.
l The air in the indoor unit and in the piping must be purged. If air remains in the
refrigerant pipes, it will affect the compressor, reduce the cooling and heating
capacity, and could lead to a malfunction.
l Be sure to use a torque wrench to tighten the service port cap (after using the
service port), so that it prevents the gas leakage from the refrigeration cycle.
l Caution: Do not leak the gas in the air during air purging.
l Air purging procedure
F Recheck the piping connections.
F Open the valve spindle of the 2-way valve counter-clockwise proximately
90°°,wait 10 seconds, and then set it to closed position. Be sure to use a hex-
agonal wrench to operate the spindle.
36
Model No: AC -S24CK_S24HK
Version 1.0
F Check the flare connections for refrigerant gas leakage.
F Purge the air from the system. Set the 2-way valve to the open position and
remove the cap from the 3-way valve’s service port. Using the hexagonal wrench
to press the valve core pin, discharge for three seconds and then wait for one
minute. Repeat this three times.
F Use torque wrench to tighten the service port cap to a torque of 1.8kg.cm.
F Set the 3-way valve to the back seat.
F Mount the valve caps to the 2-way and 3-way valves.
F Check for gas leakage. At this time, especially check for gas leakage from the
2-way and 3-way valve’s caps, and from the service port cap.
l Caution: If gas leakage is discovered, take the following measures.
F If the gas leakage stops when the piping connections are tightened fur-
ther ,continue working.
F If the gas leakage does not stop when the piping connections are tightened,
repair the location of the leakage, discharge all of the gas through the service
port, and then recharge with the specified amount of gas from a gas cylinder.
2. PUMPING DOWN (BEFORE RE-INSTALLATION)
37
Model No: AC -S24CK_S24HK
Version 1.0
l Confirm that both the 2-way and 3-way valves are set to the open position.
F Remove the valve caps and confirm that the valve spindles are in the open
position.
F Be sure to use a hexagonal wrench to operate the valve spindle.
l Operate the unit for 10~15 minutes.
l Stop operation and wait for 3 minutes, then connect the charge set to the service
port of the3-way valve.
F Connect the charge hose with the push pin to the service port.
l Air purging of the charge hose
F Open the low-pressure valve on the charge set slightly to purge air from the
charge hose.
l Set the 2-way valve to the closed position.
l Operate the air conditioner at the cooling cycle and stop it when the gauge indi-
cates 1kg/cm
2
.g.
l Immediately set the 3-way valve to the closed position.
F Do this quickly so that the gauge ends up indicating 3 to 5kg/cm
2
.g.
l Disconnect the charge set, and amount the 2-way and 3-way valve’s caps and
the service port cap.
F Use torque wrench to tighten the service port cap to a torque of 1.8 kg.m.
F Be sure to check for gas leakage.
3. RE-AIR PURGING FOR RE-INSTALLATION
l Confirm that both the 2-way valve and the 3-way valve are set to the closed
position.
l Connect the charge set and a gas cylinder to the service port of the 3-way valve.
F Leave the valve on the gas cylinder closed.
l Air purging
F Open the valves on the gas cylinder and the charge set. Purge the air by loos-
ening the flare nut on the 2-way valve approximately 45°°for 3 seconds, then
38
Model No: AC -S24CK_S24HK
Version 1.0
closing it for 1 minute. Repeat 3 times.
F After purging the air, use a torque wrench to tighten the flare nut on the 2-way
valve.
l Check the flare connections for gas leakage.
l Disconnect the charge set and the gas cylinder, and set the 2-way and 3-way
valves to the open position.
F Be sure to use a hexagonal wrench to operate the valve spindles.
l Mount the valve caps and the service port cap.
F Use torque wrench to tighten the service port cap to a torque of 1.8kg.m.
F Be sure to check for gas leakage.
l Caution: Do not leak the gas in the air during air purging.
4. BALANCE REFRIGERANT OF THE 2-WAY, 3-WAY VALVES (GAS LEAKED)
l Confirm that both the 2-way and 3-way valves are set to the back seat.
l Connect the charge set to the 3-way valve’s service port.
39
Model No: AC -S24CK_S24HK
Version 1.0
F Leave the valve on the charge set closed.
F Connect the charge hose with the push pin to the service port.
l Open the valve (Low side)on the charge set and discharged the refrigerant until
the gauge indicates 0kg/cm
2
.g.
F If there is no air in the refrigerant cycle (the pressure when the air conditioner is
not running is higher than 1 kg/cm
2
.g),discharge the refrigerant until the gauge
indicates 0.5 to 1 kg/cm
2
.g.If this is the case, it will not be necessary to apply an
evacuation.
F Discharge the refrigerant gradually. If it is discharged too suddenly, the refrigera-
tion oil will also be discharged.
5. EVACUATION (ALL AMOUNT OF REFRIGERANT LEAKED)
l Connect the vacuum pump to the charge set’s center hose.
l Evacuating for approximately one hour.
F Confirm that the gauge needle has moved toward -76cmHg (vacuum of 4
mmHg or less)
40
Model No: AC -S24CK_S24HK
Version 1.0
l Close the valve (Low side) on the charge set, turn off the vacuum pump, and
confirm that the gauge needle does not move (approximately 5 minutes after
turning off the vacuum pump).
l Disconnect the charge hose from the vacuum pump.
F If the vacuum pump oil becomes dirty or depleted, replenish as needed.
6. GAS CHARGING (AFTER EVACUATION)
l Connect the charge hose to the charging cylinder.
F Connect the charge hose which you disconnected from the vacuum pump to the
valve at the bottom of the cylinder.
F If you are using a gas cylinder ,also use a scale and level the cylinder so that the
system can be charged with liquid.
l Purge the air from the charge hose.
F Open the valve at the bottom of the cylinder and press the check valve on the
charge set to purge the air.(Be careful of the liquid refrigerant).The procedure is
the same if using a gas cylinder.
l Open the valve (Low side on the charge set) and charge the system with liquid
41
Model No: AC -S24CK_S24HK
Version 1.0
refrigerant.
F If the system can not be charged with the specified amount of refrigerant, it can
be charged with a little at a time (approximately 150g each time) while operating
the air conditioner in the cooling cycle. However, one time is not sufficient, wait
approximately 1 minute and then repeat the procedure (pumping down pin).
F This is different from previous procedures. Because you are charging with liquid
refrigerant from the gas side, absolutely do not attempt to charge with larger
amounts of liquid refrigerant while operating the air conditioner.
l Immediately disconnect the charge hose from the 3-way valve’s service port.
F Stopping partway will allow the gas to be discharged.
F If the system has been charged with liquid refrigerant while operating the air
conditioner before disconnecting the hose.
l Mount the valve caps and service port cap.
F Use torque wrench to tighten the service port cap to a torque of 1.8kg.m.
F Be sure to check for gas leakage.
42
Model No: AC -S24CK_S24HK
Version 1.0
CHAPTER 9: TROUBLESHOOTING
1. REFRIGERATION CYCLE SYSTEM
l In order to diagnose malfunctions, make sure that there is no electrical problems
before inspecting the refrigeration cycle. Such problems include insufficient
thermal insulation, problem with the power supply, malfunction of a compressor
and indoor or outdoor fan motor.
l The normal indoor outlet air temperature and pressure of the refrigeration cycle
depends upon various conditions. The standard values for them are shown in the
following table.
Normal Pressure and Outlet Air Temperature
Gas Pressure
MPa(kg/cm
2
.g)
Outlet Air Temperature
Cooling Mode 0.4~0.6(4~6) 12~16
*Condition: Indoor fan speed: High ; Outdoor DB temperature:35
l Checking procedure
Less than 8
o
C at the cooling operation
Difference in the intake
And outlet air temperature
Value of electric current
during operation
Normal
l Measure the air temp.
difference (
o
C)
Dusty condenser
Preventing heat
radiation
Excessive amount of
refrigerant
Inefficient
compressor
Insufficient refrigerant
Clogged strainer or
capillary tube
Gas side
pressure
l Measure
electric
current
during
operation
l
Measure gas side
pressure from the
service port of
the
3-way valve
43
Model No: AC -S24CK_S24HK
Version 1.0
2. RELATION BETWEEN THE CONDITION OF THE AIR CONDITIONER AND
PRESSURE AND ELECTRIC CURRENT IN COOLING OPERATION
l Carry out the measurements of pressure, electric current and temperature fifteen
minutes after an operation is started.
Condition of the air conditioner Lower pressure High pressure
Electric current during
operation
Insufficient refrigerant
(gas leakage)
Decreased Decreased Decreased
Clogged capillary tube or
strainer
Decreased Decreased Decreased
Short circuit in the indoor unit Decreased Decreased Decreased
Heat radiation deficiency of the
outdoor unit
Increased Increased Increased
Inefficient compression Increased Decreased Decreased
3. DIAGNOSIS METHODS OF A MALFUNCTION OF A COMPRESSOR
Nature of fault Symptom
Inefficient compressing of
a compressor
F Electric current during operation becomes approximately
20% lower than the normal value.
F The discharge tube of the compressor becomes abnormally
hot (normally 70 to 90)
F The difference between high pressure and low pressure
becomes almost zero.
Locked compressor F Electric current reaches a high level abnormally, and the
value exceeds the limit of an ammeter . In some cases, a
breaker turns OFF.
F The compressor has a humming sound.
44
Model No: AC -S24CK_S24HK
Version 1.0
4. TROUBLE SUSPENSION TABLE
SYMPTON PROBABLE CAUSE CORRECTIVE ACTION
The power source voltage is
lower than 198V
Repair the power supply
No voltage Repair general wiring
Correct voltage
Replace control P.C.B or
display P.C.B
The RUN indicator
(green)does not light up
The remote controller
batteries are used up
Reload new batteries
No voltage between indoor
fan motor terminals
Replace the control P.C.B
The indoor fan does not
function correctly
Indoor fan motor is broken Replace indoor fan motor
No voltage between outdoor
fan motor terminals on the
indoor power P.C.B
Replace the control P.C.B
No voltage between outdoor
fan motor terminals on the
outdoor unit
Check and repair electrical
wiring between indoor and
outdoor units
Outdoor fan is blocked Remove obstructions
Outdoor fan motor is broken Replace outdoor fan motor
The outdoor fan does not
function correctly
Outdoor fan motor capacitor
is broken
Replace capacitor
No voltage between
compressor terminals on the
indoor unit
Repair control P.C.B
Low voltage between
compressor terminals on the
indoor unit
Repair control P.C.B
No voltage between
compressor terminals on the
outdoor unit
Repair electrical wiring
between indoor and outdoor
units
The running capacitor is
broken
Replace running capacitor
OLP of compressor trips Wait for one hour or so
The compressor does not
start up
Compressor winding shorted
or broken
Replace compressor
45
Model No: AC -S24CK_S24HK
Version 1.0
SYMPTON PROBABLE CAUSE CORRECTIVE ACTION
The refrigeration
system does not
function correctly
Check for leakage or restriction
with ammeter, pressure gauge
or surface thermometer
Repair refrigeration system and
charge refrigerant if necessary
something wrong with power
P.C.B
Replace control P.C.B
No cooling or
heating, only
indoor fan
operates
Outdoor fan motor faulty or other
fault caused compressor OLP
trips
Remove obstruction or other fault
Compressor OLP trips because
of low voltage, high
temperature,R22 leakage, little
outdoor air circulation and etc
Check the problems and try
again one hour later
Running capacitor faulty Replace running capacitor
No cooling or
heating, indoor and
outdoor fan
operate
Compressor is broken Replace compressor
Water accumulates
and overflows from
indoor unit
Drainage hose or port of
drainage pan clogged
Remove clogged dirt
Power supply failure Repair power supply
The secondary voltage of
transformer is approximately
17VAC
Replace control P.C.B
The air conditioner
does not function
at all with remote
controller or AUX
switch button on
the indoor unit
The secondary voltage of
transformer is not approximately
17VAC
Replace transformer
5. Checking procedure of control circuit
Note: Do not check indoor and outdoor units at the same time. Be sure to check them
one by one.
46
Model No: AC -S24CK_S24HK
Version 1.0
Is the measured
value approx.
17.0 V AC?
Is the connecting
cord correctly
connected?
Correct the
connecting
cord correctly
Use a tester to measure
the voltage between “L”
and “N” of terminal
board on the
outdoor unit
Check the electric
circuit on the outdoor
unit
Is the fuse
down?
Replace the transformer
with a new one.
Replace the fuse and
varister with new ones
Yes
Correct
power supply
between “L” and “N”
of terminal board?
Yes
Replace the control P.C.B.
with a new one.
Measure the secondary
voltage of transformer
The machine does not function
at all with remote controller and
EMERGENCY button on the
indoor unit.
None of the three
LEDs is ON
47
Model No: AC -S24CK_S24HK
Version 1.0
YES
YES
NO
YES
NO
YES
NO
YES
NO
YES
YES
The machine does not function
with the remote controller.
Push the ON/OFF button on the
wireless remote controller.
Is transmitting
signal of the remote
controller active?
Does connector of
display P.C.B.
connect in place?
Using a tester, measure the
voltage of the receiver on
display P.C.B.assembly.
Push the ON/OFF button
on the remote controller.
Replace the display
P.C.B.
assembly with a new
one.
When the signal is
received, does the
voltage change?
Is timer lamp
of indoor unit
flashing?
Indoor unit is normal.
Inspect the outdoor
Unit or refer to
trouble
Suspension Table.
Refer to
Trouble
Suspension
Table.
Replace the control
P.C.B.assembly
Replace the batteries
with new ones.
NO
Replace the wireless
remote controller.
Are batteries of
remote controller
proper?
Does beep sound
from the indoor
unit?
Replace the control P.C.B.
assembly with a new one
Is indicator lamp
of indoor unit
proper?
NO
48
Model No: AC -S24CK_S24HK
Version 1.0
NO
YES
NO
YES
The room is not cooled at all or not cooled enough
in cooling operation.
The room is not heated at all or not heated enough
in heating operation.
The compressor does not operate.
Push the buttons
EMERGENCY
on the indoor unit.
Refer to Trouble Suspension Table
Measure the resistances of room temperature
and indoor pipe temperature thermisters.
Some of the three indicator LEDs are lit.
Measure the secondary voltage of transformer.
Is the measured
value approximately
17.0 V AC?
Replace the control P.C.B. with a new one.
Replace the transformer
with a new one.
Replace the fuse and varister
with a new one.
Is the fuse
breakdown?
49
Model No: AC -S24CK_S24HK
Version 1.0
7. Exploded view of indoor unit for model: AC-S24CK, AC-S24HK
50
Model No: AC -S24CK_S24HK
Version 1.0
8.Exploded view of outdoor unit for model: AC-S24CK
51
Model No: AC -S24CK_S24HK
Version 1.0
9. Exploded view of outdoor unit for model: AC-S24HK
52
Model No: AC -S24CK_S24HK
Version 1.0
13. Part List of Indoor Unit for AC-S24CK
No. DESCRIPTION Part No. Qty
1 Installation Plate 1101303 1
2 Pipe Clamp A 1109257 1
3 Pipe Clamp B 1109255 1
4 Chassis 1002160 1
5 Indoor Fan 1402367 1
6 Bearing 120266 1
7 Evaporator Assembly 1301389 1
8 Pipe Assembly 13032791 1
9 Cabinet 8100413 1
10 Screw Cover 2109302 3
11 Air Filter 1306178 2
12 Front Cover 8100619 1
13 Electric Box Cover 2109304 1
14 Transformer 814053 1
14a Transformer 140513 1
15 Electric Box 1005228 1
16 Indoor Fan Motor 1402369 1
17 Control PCB 8140913 1
18 Power Supply PCB 8140915 1
19 Motor Fixing Ring 1203411 1
20 Terminal Board 3PS 150265 1
21 Terminal Board 5PU 150262 1
22 Power Supply Cord 1501185 1
23 Display PCB 8140914 1
24 Drain Hose 210995 1
25 Drain Draining Pan 2106101 1
26 Support 1201374 3
27 Louver Motor 1402136 2
28 Louver Link 1201375 2
29 Vertical Deflector A 1201372 2
30 Vertical Deflector B 1201373 14
31 Bearing Support 100251 8
32 Horizontal Louver A 1201370 1
33 Horizontal Louver B 1201371 1
34 Remote Controller 1401394 1
35 Thermistor 1411366 1
53
Model No: AC -S24CK_S24HK
Version 1.0
14. Part List of Outdoor Unit for AC-S24CK
No. DESCRIPTION Part No Qty
1 Top Cover 810132 1
2 Back Lattice Plate 810091 1
3 Condenser 813024 1
4 Motor Stay Bracket 811021 1
5 Outdoor Fan Motor 1402370 1
6 Outdoor Fan 140239 1
7 Cabinet 810134 1
8 Fan Guard 821071 1
9 Right Side Plate 10033032 1
10 Terminal Cover 2109236 1
11 Bulkhead 12133035 1
12 Electrical Assembly 8140124 1
13 Cord Clamp 1 110962 1
14 Cord Clamp 2 110963 1
15 Terminal Board 3PUA 150298 1
16 Terminal Board 2U 150217 1
17 Fan motor Capacitor 14113058 1
18 Compressor Capacitor 14113044 1
19 Capacitor Fixing Ring 12033022 1
20 Power Supply Cord 15013059 1
21 Electrical Assembly Plate 10053005 1
22 Chassis 8100212 1
23 3 Way Valve 8130914 1
24 2 Way Valve 8130918 1
25 Link Pipe 1303038 1
26 Discharge Pipe 8130356 1
27 Compressor 1304212 1
28 Suction Pipe 13031578 1
29 Capillary Tube Assembly 13032825 1
54
Model No: AC -S24CK_S24HK
Version 1.0
15. Part List of Indoor Unit for AC-S24HK
No. DESCRIPTION Part No. Qty
1 Installation Plate 1101303 1
2 Pipe Clamp A 1109257 1
3 Pipe Clamp B 1109255 1
4 Chassis 1002160 1
5 Indoor Fan 1402367 1
6 Bearing 120266 1
7 Evaporator Assembly 1301389 1
8 Pipe Assembly 13032791 1
9 Cabinet 8100413 1
10 Screw Cover 2109302 3
11 Air Filter 1306178 2
12 Front Cover 8100619 1
13 Electric Box Cover 2109304 1
14 Transformer 814053 1
15 Electric Box 1005228 1
16 Indoor Fan Motor 1402369 1
17 Control PCB 8140918 1
18 Power Supply PCB 8140910 1
19 Motor Fixing Ring 1203411 1
20 Terminal Board 3PS 150265 1
21 Terminal Board 5PU 150262 1
22 Power Supply Cord 1501185 1
23 Display PCB 8140914 1
24 Drain Hose 210995 1
25 Drain Draining Pan 2106101 1
26 Support 1201374 3
27 Louver Motor 1402136 2
28 Louver Link 1201375 2
29 Vertical Deflector A 1201372 2
30 Vertical Deflector B 1201373 14
31 Bearing Support 100251 8
32 Horizontal Louver A 1201370 1
33 Horizontal Louver B 1201371 1
34 Remote Controller 1401394 1
35 Thermistor 1411366 1
55
Model No: AC -S24CK_S24HK
Version 1.0
16. Part List of Outdoor Unit for AC-S24HK
No. DESCRIPTION Part No. Qty
1 Top Cover 810132 1
2 Back Lattice Plate 810091 1
3 Condenser 13023037 1
4 Motor Stay Bracket 811021 1
5 Outdoor Fan Motor 1402370 1
6 Outdoor Fan 140239 1
7 Cabinet 810134 1
8 Fan Guard 821071 1
9 Side Plate 10033032 1
10 Thermistor 1411989 1
11 Bulkhead 12133035 1
12 Electrical Assembly 8140123 1
13 Terminal Board 5P4 150294 1
14 Terminal Board 2U 150217 1
15 Fan motor Capacitor 14113058 1
16 Compressor Capacitor 14113044 1
17 Cord Clamp1 110962 1
18 Cord Clamp2 110963 1
19 Power Supply Cord 15013059 1
20 Capacitor Fixing Ring 12033022 1
21 Electrical Assembly Plate 10053005 1
22 Terminal Cover 2109236 1
23 Chassis 8100212 1
24 3 Way Valve Assembly 8130914 1
25 2 Way Valve Assembly 8130918 1
26 4 Way Valve 1411585 1
26a 4 Way Valve Coil 1411458 1
27 Compressor 1304212 1
28 Capillary Assembly 13032818 1
Description
Akira Model No. AC-S7CK AC-S7HK AC-S10CK AC-S10HK AC-S13CK AC-S13HK AC-S19CK AC-S19HK AC-S24CK AC-S24HK
Type (Cool only / Heat Pump) C C/H C C/H C C/H C C/H C C/H
Cooling Capacity (Btu)
Heating Capacity (Btu)
N/V
7000
N/V
10000
N/V
13000
N/V
19000
N/V
24000
Power Input (W)
Current (A)
EER (Btu/Hw)
Indoor Noise (H/L)
Circulation Air Flow(m3/h)
Indoor Unit (WxDxH)mm
Indoor Unit Carton (WxDxH)mm
Outdoor Unit (WxDxH)mm
Outdoor Unit Carton (WxDxH)mm
Indoor N/G Wt (kg) 8.0/10 8.0/10 8.0/10 8.0/10 8.0/10 8.0/10 11.0/14 11.0/14 13.2/21 13.2/21
Outdoor N/G Wt (kg) 26.0/31 30.0/35 28.0/33 30.0/35 28.0/33 34.0/39 50.0/58 53.0/61 55.0/63 56.0/64
Compressor Brand Mitsubishi Toshiba LG Toshiba
Gas Pipe Diameter
Liquid Pipe Diameter
Piping (m)
40HQ CTN Loading
Indoor Unit Picture
245 sets 152 sets 123 sets
3/8" (or 10mm)
890x350x580
3/8" (or 10mm)
1130x300x395
832x380x702
970x765x410
Hitachi
5/8" (or 16mm)
770x179x240
830x240x310
755x252x530
1/4" (or 6mm)1/4" (or 6mm)
800x268x637
975x400x755
Mitsubishi LG
1/2" (or 12mm)
55
420 420 480 750 780
APPENDIX AAPPENDIX A
Singapore / AKIRASingapore / AKIRA
800 1425 1590 2700
9.1
24000
9.0 8.6
7.5
10 8.89
12.5
897x179x297
1010x300x410
1025x203x3139
7000
730
3.4
10000 13000 19000
6.23.7
35/30Db 38/33Db 43/37Db35/30Db 40
42

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Akira AC-S24 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Akira AC-S24 in de taal/talen: Engels als bijlage per email.

De handleiding is 6,73 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info