618065
7
Verklein
Vergroot
Pagina terug
1/56
Pagina verder
7
A300/A300 XT OPERATING MANUAL
© 2002 Design, 2012 Doc. No. 12-7255-r01 (5/14/12)
AUDIBLE ALARM
While operating in NOR, TEC, or GAU mode, the Audible will emit 1 beep per second for 10 seconds when alarms strike, unless it is set Off. During that
time, the Audible can be acknowledged and silenced by pressing the S button (less than 2 seconds).
An LED Warning Light, on the housing, is synchronized with the Audible and flashes as the Audible sounds. It will turn Off when the Alarm is silenced. The
Audible and LED will not be active if the Audible is set OFF (a group A setting).
Situations that will activate the 10 second Alarm include -
** Items apply only in NORM/TECH modes.
*** Items apply only in TECH mode.
• Low Pressure, at 500 PSI (35 BAR) (A300 XT only).
• Descent deeper than the Depth Alarm Set Point.
• Dive Time Remaining at the Set Point**.
• Elapsed Dive Time at the Set Point.
• PO2 (for Gas in use) level at .20 < Set Point and again at the Set Point**.
• O2 accumulation at 240 OTU (80%), then again at 300 OTU (100%)**.
• TLBG at the Set Point**.
• Ascent Rate exceeds 60 FPM (18 MPM) when deeper than 60 FT (18 M), or 30 FPM (9 MPM) at 60 FT (18 M) and shallower.
• Entry into Decompression Mode (Deco)**.
• Conditional Violation (above a required Deco Stop Depth < 5 minutes)**.
• Delayed Violation (above a required Deco Stop Depth => 5 minutes)**.
• Delayed Violation (a Deco Stop Depth > 60 FT/18 M is required)**.
• Delayed Violation (Depth > 330 FT/100 M in NORM/TECH, > 400 FT/120 M in GAUG).
• A Gas Switch would expose the diver to PO2 => 1.60 ATA***.
A single short beep (which cannot be disabled) sounds when -
• After 5 minutes on the surface after the Violation dive.
3 short beeps sound when -
• Ascent Rate is 51 to 60 FPM (15.1 to 18 MPM) when deeper than 60 FT (18 M), or 26 to 30 FPM (7.5 to 9 MPM) at 60 FT (18 M) and shallower.
• FREE - Elapsed Dive Time every 30 seconds during dive.
• FREE - descent deeper than the Depth Alarm Set Points (1, 2, 3).
• FREE - Delayed Violation (Depth > 330 FT/100 M).
• FREE - CDT counts down to 0:00.
• FREE - TLBG at 14 segments.
• FREE - Violation, entry into Deco.
During the following situations, the audible will not turn off when acknowledged -
• Delayed Violations.
• Deco Stop Depth Violation => 70 FT/21 M stop required.
• FREE mode alarms.
PC INTERFACE
Interface with a PC, to allow uploading settings and downloading data, is accomplished by connecting the unit to a PC USB Port using the special USB
Interface Cable.
The software program together with the USB Driver required is on the ACI (AERIS Computer Interface) CD, and can be downloaded from the AERIS web
site. The program's HELP** serves as the user manual which can be printed for personal use.
**Prior to attempting to Download data from your unit or Upload Settings to it, review the HELP section of the ACI program. Recommended is to print
those sections of HELP that you consider appropriate for your Interface activities.
The Settings Upload portion of the ACI program can be used to set/change the Set Alarms group, Set Utilities group (Utilities), Set Time, etc. using the same
Interface System. FO2 related items must be set using the control buttons.
Information available for retrieval (download) from the unit to the PC Download portion of the program includes dive data such as number, surface interval
time, maximum depth, elapsed dive time, no deco status, start date/time, lowest temperature under water, sampling rate, dive profile, and Set Points.
The ACI program also allows upgrade of select versions of the unit's firmware (operating system software) after which the unit resets all operating data.
Since the upgrades require reset of the unit, they are blocked during 24 hours after dives.
Refer to page 45 for more details relating to PC Interface.
7

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Aeris A300 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Aeris A300 in de taal/talen: Engels als bijlage per email.

De handleiding is 14,46 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info