SETTING NORM/TECH FO2 AND PO2 ALARMS
NORM is for use with only 1 Gas for which FO2 can be set for Air, and 21 to 100% Nitrox. The PO2 Alarm is fixed at 1.40
with a Warning fixed at 1.20.
TECH is for use with up to 3 Gas’ each of which FO2 can be set for Air, and 21 to 100% Nitrox. Each Gas has a separate PO2
Alarm which can be set from 1.00 to 1.60 with a Warning fixed at 0.20 less.
There is no FO2 50% Default setting like previous AERIS Nitrox dive computers.
Until a dive is conducted, FO2 for NORM and TECH remain at the values set for that mode (even if the mode is changed). When
the unit shuts off, the settings revert to Air (the default for all gasses).
After a dive is conducted, FO2 Gas 1 remains at the value set for the mode in which the dive was conducted (NORM or TECH),
and the setting automatically carries over to the other mode even if it had a different setting prior to the dive.
The PO2 alarm value for NORM remains fixed at 1.40 and the values for TECH remain as set, even if the mode is changed
between dives.
FO2 set for Air:
The default FO2 for all Gas’ each new period of activation is AIR.
When FO2 is set for AIR -
. . calculations are the same as when it is set for 21% O2.
. . it remains set for AIR until it is set for a numerical value (21 to 100%).
. . O2% and PO2 values and/or warnings will not be displayed at any time, on the surface or during dives.
. . max depths allowed by the PO2 limit set will not be displayed in Plan.
Internally, the unit will keep track of the oxygen loading so that if FO2 for Gas 1 is later set for a numerical value of FO2, the
oxygen accumulated during previous Air dives will be accounted for in the next Nitrox dive (during that series of repetitive dives).
FO2 set for Nitrox:
When FO2 for any Gas is set for a numerical value (21 to 100%), the dive is considered Nitrox with the NX icon displayed on
all applicable screens.
Once a dive is conducted with FO2 for Gas 1 is set for Nitrox, the Air option for any gas will be disabled until 24 hours elapse
after the last dive. The Air option will not be displayed in Set FO2 until a full 24 hour Surface Interval has elapsed.
NORM/TECH SET GAS LEAD-IN, information includes (Fig. 26):
> Graphics Go To GAS with SET icon.
S (< 2 sec) to access Set Gas 1.
A (< 2 sec) to step forward to Set ALM Lead-in.
M (< 2 sec) to step back to Set OP MOD Lead-in.
2 minutes, or M (2 sec), revert to Main.
NORM/TECH SET GAS 1, information includes (Fig. 27, 28):
> SET, FO2, Gas (tank) 1 icons.
> CF, Z+ (or DSAT) icons, if they apply.
> Graphic AIR flashing, or -
. . Max Depth allowed with FT (or M) and MAX icons.
. . FO2 (numeric) value flashing.
Since there are only 2 digits, 100% is displayed as 00.
. . PO2 Alarm value with PO2 icon.
NORM is fixed at 1.40 (cannot be set), TECH can be set.
A (hold) to scroll upward through FO2 settings from Air to 21 through 100% in 1% increments at 8/sec, stopping when the
button is released, or at 32, then at 50, then at 80 (even if A is held depressed).
A (hold) again to resume the scroll upward through 100%, then stop at Air (or 21 if a repetitive Nitrox dive).
A (< 2 sec) to step upward through the Set Points one at a time.
M (< 2 sec) to step back through the Set Points one at a time.
S (2 sec), if the setting is not changed, to step back to Set Gas Lead-in.
2 minutes, or M (2 sec), revert to Main.
S (< 2 sec), if NORM, to save the setting and revert to Set Gas Lead-in.
S (< 2 sec), if TECH, to save the setting and flash the PO2 digits if Nitrox, or access Set Gas 2 if Air.
To set PO2, if flashing -
A (< 2 sec) to step upward through the Set Points of 1.00 to 1.60 one at a time in increments of 0.05.
M (< 2 sec) to step back through the Set Points one at a time.
S (< 2 sec) to save the PO2 Alarm setting and access Set Gas 2 (revert to Set Gas Lead-in after Gas 3).
S (2 sec) to step back to Set Gas Lead-in.
Fig. 26 - SET GAS LEAD-IN
Fig. 27 - SET GAS 1
(for Air)
Fig. 28 - SET GAS 1
(for Nitrox)
14

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Aeris A300 XT bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Aeris A300 XT in de taal/talen: Engels als bijlage per email.

De handleiding is 14,46 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info