618070
15
Verklein
Vergroot
Pagina terug
1/52
Pagina verder
15
A300 AI OPERATING MANUAL
© 2002 Design, 2011 Doc. No. 12-7265-r01 (12/28/11)
FO2 50% Default -
> When the Default is set OFF, FO2 values will remain set at their last settings saved until 24 hours elapse without conducting
a dive.
> When the Default is set ON and FO2 is set for Nitrox, 10 minutes on the surface after that dive the FO2 will be displayed
as 50 and further dives will be calculated based on 50% O2 for oxygen calculations and 21% O2 for Nitrogen calculations
(79% Nitrogen), unless FO2 is set before the dive.
> FO2 will continue to reset to the Default after repetitive dives until 24 hours elapse with no dive, or the Default is set OFF.
SET F (FO2) MENU, information includes (Fig. 22):
> Graphics SEt and MENU,
with the following graphic selections with their last Set Points saved.
> GAS1 AIR
Set Points of AIR, 21 to 100%, increments of 1%
.
> GAS2 32%
Set Points of OFF, AIR, 21 to 100%, increments of 1%
.
> GAS3 80%
Set Points of OFF, AIR, 21 to 100%, increments of 1%
.
> GAS4 OFF
Set Points of OFF, AIR, 21 to 100%, increments of 1%
.
> DEFAULT ON
Set Points of OFF, ON
.
When Gas 2 is OFF, Gas 3 & 4 remain OFF, and when Gas 3 is OFF Gas 4 will remain OFF. This blocks access to the Gas
Switch screens for gasses not selected for use.
During the time that numeric FO2 values (21 to 100) are flashing, the MOD (Max Operating Depth) allowed for the PO2
alarm set will be displayed in place of the graphic SEt, and the PO2 alarm value set will be displayed in place of the
graphic MENU.
• S (< 2 sec) - to access Set F Menu while the selection Arrow icon ( > ) is next to Set F on the NORM Menu.
• A (< 2 sec) - to step down (forward) through selections.
• M (< 2 sec) - to step up (back) through selections.
• S (< 2 sec) - to access selection indicated by Arrow icon ( > ).
This causes the FO2 setting to flash allowing it to be set.
• S (2 sec) - to step back from Set F Menu to SET Menu.
SET FO2 & PO2 ALARMS:
A (press/hold), while the FO2 digits are flashing (Fig. 23A) - to scroll upward through the Set Points from Air to 21 through
100 in 1% increments, at a rate of 8 per second.
The scroll will stop when the button is released, or momentarily at 32, then 50, then 80 (%).
A (< 2 sec) - to step upward through FO2 Set Points one at a time.
M (< 2 sec) - to step back through FO2 Set Points one at a time.
S (< 2 sec) - save the FO2 setting, and flash the PO2 digits if Nitrox (Fig. 23B), or revert to SURF MAIN if Air.
A (< 2 sec) - to step upward through PO2 Alarm Set Points from 1.00 to 1.60 (ATA) in .05 increments.
M (< 2 sec) - to step back through PO2 Set Points.
S (< 2 sec) - to save the PO2 setting and access Set Gas 2.
S (2 sec) - to revert to Set F Menu displaying the settings.
M (2 sec) or if no button is pressed during a 2 minute period - to revert to SURF MAIN.
Once any Gas is set for Nitrox, any other Gas set for Air will automatically be set to 21%.
SET FO2 50% DEFAULT, information includes (Fig. 23C):
> Graphics DEFAULT and 50.
> Set Point graphic OFF (or ON), flashing.
> Nx icon.
• A or M (< 2 sec) - to toggle between OFF and ON.
• S (< 2 sec) - to save the setting and revert to Set F.
SET A (ALARMS) MENU, information includes (Fig. 24A/B):
> Graphics SEt A and MENU,
with the following graphic selections with their last Set Points saved.
> AUD ON
Set Points of OFF, ON >> Audible.
> DEPTH 140 FT
Set Points of OFF, 30 to 330 FT (or 10 to 100 M), increments of 10 FT (3 M).
> EDT 60 MIN
Set Points of OFF, 10 to 180 MIN, increments of 5 MIN >> Elapsed Dive Time.
> TLBG* 4 BAR
Set Points of 1 to 4 BAR, increments of 1 BAR >> Tissue Loading Bar Graph.
> DTR* 5 MIN
Set Points of OFF, 1 to 20 MIN, increments of 1 MIN >> Dive Time Remaining.
> TURN 1400 PSI
Set Points of OFF, 1000 to 3000 PSI (or 70 to 205 BAR), increments of 250 PSI (5 BAR).
> END 500 PSI
Set Points of 300 to 1500 PSI (or 20 to 105 BAR), increments of 100 PSI (5 BAR).
*These items apply to NORM only.
A (< 2 sec) to toggle or increase Set Point.
A (hold) to increase Set Point at a rate of 8 per second.
M (< 2 sec) to decrease Set Point.
S (< 2 sec) to save the setting and revert to the Set A Menu.
• S (2 sec) - to step back from Set A Menu to SET Menu.
Fig. 22 - SET F MENU
(stepping through)
Fig. 23A - SET FO2
(changing the setting)
Fig. 23B - SET PO2 ALARM
(after FO2 setting is saved)
Fig. 23C - SET FO2 50%
DEFAULT
Fig. 24A - SET A MENU
(stepping through)
Fig. 24B - SET END ALARM
(sample of changing a setting)
15

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Aeris A300 AI bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Aeris A300 AI in de taal/talen: Engels als bijlage per email.

De handleiding is 11,42 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info