38
What to do if ...
Changing the light bulb
Warning! There is a risk of electric shocks! Before changing the light
bulb, switch off the appliance and unplug it, or pull the fuse or the
circuit breaker.
Light bulb data: 220-240 V, max. 15 W
☞
1. To switch off the appliance, turn the temperature regulator to
position "0".
2. Unplug the mains plug.
Symptom Possible Cause Remedy
The food is too warm.
Temperature is not proper-
ly adjusted.
Please look in the “Starting
up and temperature regu-
lation” section.
Door was open for an
extended period.
A large quantity of warm
food was placed in the
appliance within the last
24 hours.
The appliance is near a
heat source.
Open the door only as long
as necessary.
Turn the temperature
regulator to a colder set-
ting temporarily.
Please look in the
“Installation location” section.
Light bulb is defective.
Interior lighting does not
work.
Please look in the “Changing
the Light Bulb” sections.
Heavy build up of frost,
possibly also on the door
seal.
Door seal is not air tight
(possibly after reversing
the door).
Carefully warm the leaking
sections of the door seal
with a hair dryer (on a
cool setting). At the same
time shape the warmed
door seal by hand such
that it sits correctly.
The compressor does not
start immediately after
changing the temperature
setting.
This normal, no error has
occurred.
Water on the floor or on
storage shelves.
Water drain hole is
blocked.
See the “Cleaning and
Care” section.
The compressor starts after
a period of time.