7
- hours in range: 1-24, when you program delayed start or delayed stop
- “LO” – means low, when the environment humidity is lower than 35%
- "HI" - means high, when the environment humidity is higher than 95%,
USAGE
1. Plug in the device.
2. Press the power button (A) to start operation, the digital “88” indicator (J) will be lighted on. Press the power button (A) again to stop
operation.
3. Press the bottom (C) or (D) to set the desired humidity level in the room, which can be set from 30% to 90% at 5% intervals or “CO”.
After a period of working:
- when environment humidity is lower than the selected humidity by 2%, compressor will stop,
- when environment humidity is equal to or higher than the selected humidity by 3%, the compressor will restart once 3-minute compressor
protection time over.
4. TIMER FUNCTION
Press the timer button (D) is the program the time:
- when the device is turned on to set up the delayed stop function:
Repeatedly pressing of the timer button (D) adjust desired time, it will be circulate from 0-1-2……23-24. The time indicator (E ) will be
lighted on. The device will stop operation when desired time passed.
- when the device is turned off to set up the delayed start function:
Repeatedly pressing of the timer button (D) adjust desired time, it will be circulate from 0-1-2……23-24. The time indicator (E ) will be
lighted on. The device will start operation when desired time passed.
To cancel the timer programming, press the timer button (D) to zero.
The programmed time remains unchanged if the machine stops to work due to full water tank or during self-defrosting.
5. WATER TANK DRAINAGE
When the water tank (7) is full, the indicator (H) light up, the operation will stop automatically and the buzzer will beep 15 times to alert the
user, that the water need to be emptied from the water tank (7). Look at pictures 4 and 5. The water drainage procedure is:
- Lightly press on the sides of the tank (7) with both hands and pull the tank out gently.
- Pour out the collected water. If the water tank (7) is dirty, wash it with cold or lukewarm water.
REMARK: Do not remove the float laver (11) from the water tank (7). The built-in full water sensor will no longer be able to detect the water
level correctly without the float laver (11) and the device will stop operation.
- When putting back the water tank (7), press the tank firmly into place with both hands. If the tank is not positioned properly, the built-in full
water sensor will be not activated, so the dehumidifier will not operate.
6. CONTINUOUS WATER DRAINAGE FUNCTION
When setting the humidity level to “CO” on digital display (J), the compressor will run continuously. The user can:
6.a. connect the drain hose (10)
If the user connects the drain hose (10), the water will drain out continuously to sink / bathtub or other outside container you will set up. The
device features a continuous water drainage port (14) - look at picture 3. It is need to take out the water tank (7) to assemble the drain hose
(10) to the continuous water drainage port (14). The drain hose (10) (with an inner diameter of 10mm) should be put on the port (14) drain
hole shown at picture 3. The water can be continuously drained out from the port (14).
6.b. do not connect the drain hose (10).
If the user doesn't connect the drain hose (10), the water will drain to the water tank (7). When the water tank (7) be full, the device will stop
operation automatically.
7. AUTO DEFROST FUNCTION
When frost builds up on the built-in evaporator coil, the compressor will cycle off and the device will go in to self-defrost mode automatically.
Following completion of the defrost mode, the device will return to the previously operating settings. When the device is running in a room
with a temperature between 5 degree of Celsius and 12 degree of Celsius, it will enter self-defrost mode roughly every 30 minutes. When
the device is running in a room with a temperature between 12 degree of Celsius and 20 degree of Celsius, it will enter the self-defrost
mode roughly every 45 minutes.
Cleaning and Maintenance
1. Turn off the unit and disconnect the power plug before starting any cleaning or other routine maintenance.
2. To avoid the risk of electric shock, never sprinkle or spill water on the dehumidifier when cleaning.
3. Turn off the device and empty the water out of the water tank before moving the device. Be sure to hold by the handle while moving.
4. Wipe up the housing of the device with wet cloth.
5. Don't dismantle the floater (11) from the water tank (7). To clean the water tank (7) do not use detergent, scouring pads, chemically
treated dust cloths, gasoline, benzene, thinner, or other solvents, as these can scratch and damage the tank and cause water leakage.
6. Prior to planned continuous operation for a long duration, periodical checking is required especially for the net air filter (12) and the drain
hose (10).
7. To clean or replace the filters should be:
7

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Adler AD 7861 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Adler AD 7861 in de taal/talen: Nederlands, Duits, Engels, Frans, Italiaans, Portugees, Spaans, Pools, Deens, Zweeds als bijlage per email.

De handleiding is 2.69 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info