English
13
8. Country and function settings
The SD1+ is supplied with four DIP switches (see Chapter 4) that allow you to
configure the unit for different countries and functional modes.
Multi-mode: The unit works as described in the installation instructions. All four
alarm inputs, all alarm texts, and all four alarm call numbers are active.
Single-mode: In this mode the unit uses only one alarm call number, which is
freely programmable (factory set to "999”). Only alarm input 1 can be
activated. In the event of an alarm, only the general identification text
is transmitted. The acknowledgment mode is set so that no acknow-
ledgement is necessary.
SW1 SW2 SW3 SW4 Mode Country
Off Off Off Off Multi UK, Ireland, Denmark
On Off Off Off Multi Belgium
Off On Off Off Multi Holland & Norway
Off On Off Off Multi France
Off On On Off Multi Italy
Off Off On Off Multi Not used
On Off On Off Multi Not used
Off On On Off Multi Germany & Finland
On On On Off Multi Not used
Off Off Off On Single UK, Ireland, Denmark
On Off Off On Single Belgium
Off On Off On Single Holland & Norway
Off On Off On Single France
Off On On On Single Italy
Off Off On On Single Not used
On Off On On Single Not used
Off On On On Single Germany & Finland
On On On On Single Not used