135
Ventilation
De elektronica in het toestel heeft kThe electronics in the appliance
require cooling. The ventilation openings are located on the underside of
the appliance. It must be possible for cool air to be drawn in through
these openings. The appliance is fitted with outlet openings at the front
and bottom. The kitchen unit will require a few modifications to allow
optimum cooling of the hob.
Above drawer or fixed panel
Saw out the ventilation openings (min. 100 cm
2
). Ventilation is via plinth
and rear of cupboard.
Do not allow the ventilation openings on the underside of the appliance
to be blocked by a drawer. Where there is a drawer, a gap of at least
560 x 6 mm should be made at the front. The distance between drawer A
and the hob should be a minimum of 10 mm.
building in INSTALLATION
min.
min.
134
INSTALLATION building in
Cut opening in worktop
Saw the opening in the worktop. This should be done very accurately
(see table). Also saw out any partitions that may be present. The distance
from the saw line to the rear wall and/or side wall is indicated in the
table.
Table
Space to be left free around the appliance
min. 600 mm
min. 650 mm
min. 450 mm
min. 40 mm
min. 40 mm
Type of hob
HI6071T
Appliance width x depth
604 x 512 mm
Installation height from top of worktop
48 mm
Cut out dimensions width x depth
560 x 490 mm
Distance from saw line to rear wall
Minimaal 50 mm
Distance from saw line to side wall
Minimaal 50 mm