24
Symptom Possible Cause
The food is too warm.
Temperature is not
properly adjusted.
Please look in the “Initial
Start Up” section.
Remedy
Heavy build up of frost,
possibly also on the door
seal.
Door was open for an
extended period.
A large quantity of warm
food was placed in the
appliance within the last
24 hours.
The appliance is near a
heat source.
Door seal is not airtight
(possibly after reversing
the door).
Carefully warm the leaking
sections of the door seal
with a hair dryer (on a
cool setting). At the same
time shape the warmed
door seal by hand such
that it sits correctly.
Do not leave the door open
any longer than necessary.
Turn the thermostat knob
to a colder setting tem-
porarily.
Please look in the
“Installation location” section.
The compressor does not
start immediately after
changing the temperature
setting.
This is normal, no error has
occurred.
Water in the bottom of
the cabinet.
Water drain hole is
blocked.
See the “Cleaning and
Care” section.
The compressor starts after
a period of time.
Changing the light bulb
Warning! There is a risk of electric shocks! Before changing the light
bulb, switch off the appliance and unplug it, or disconnect from the
power supply.
Light bulb data: 220-240 V, max. 15 W
To switch off the appliance, turn the thermostat knob to position "0".
Unplug the mains plug.
To change the light bulb, undo the screw.
Press the light bulb cover as shown
and slide it backwards.
Change the defective light bulb.
Refit the light bulb cover and the
screw.
Put the refrigerator back into
operation.
☞
☞
☞
☞
☞
☞
☞