For the Professional
English
2. Installation instructions
2.1 Provisions and regulations
This unit are not suitable for rooms which are subjects to a fire or explosion risk caused by chemicals,
dust, gases or vapours. In workshops or other areas in which the odour of waste gases, oil, petrol, etc.
might occur, or in which work is carried out involving solvents and chemicals, there is a risk of sustained
odour burdens being engendered, and possibly of dirt contamination occurring.
See 1.3 Safety instructions!
The unit may only be fitted with the hanging brackets (7) on a vertical wall which is temperature resistant to
at least 80 °C.
The minimum distances from adjacent objects must be observed
A
.
All electrical connection and installation work is to be carried out in accordance with the I.E.E Regulations, the
provisions of the appropriate electricity supply companies, and the relevant national and regional provisions.
The unit must not be fitted nor positioned directly beneath an electrical wall socket.
The appliance should be installed such that the plug is still accessible.
The unit rating plate is to be noted. The stated voltage must correspond to the mains voltage
If the mains connection cable is changed, this may only be replaced with original AEG spare parts by a quali-
fied installer.
2.2 Unit installation
2.2.1 Fitting the feet
B
The feet (6), including securing screws, are supplied with the unit as standard.
Insert the feet with the guide bars - of variable size - into the side sections at the bottom, and screw tightly.
When doing this, note that in the case of the right-hand foot (6a), the mains connection cable is fed through
the channel in the foot.
2.2.2 Wall mounting
C
(only possible without the feet fitted)
The following action should be taken to secure the unit:
Fix the hanging brackets (7) vertically to the wall. Use suitable securing materials (screws, dowels etc.), de-
pendant on the type of wall.
Observe the minimum distance from the floor!
hang the unit onto the hanging brackets using the vertical recesses in the rear panel of the unit;
using a screwdriver, turn the retaining clips (at the top of the hanging bracket) clockwise into the unit - the
unit is then secured against unintentional removal.
2.3 Electrical connection
Electrical connection can only be made to an a.c. 230V ~ 50 Hz supply.
For the purpose of connection, an earthed socket or unit connection box for permanent connection should be
installed at the side of the heating unit, at least 10 cm away from it.
2.4 Handover
Explain the functions of the unit to the user. Draw his or her attention to the safety instructions, in particular.
Hand the operating and installation instructions to the user.
3. Guarantee
For guarantees please refer to the pespective terms and conditions of supply for your country.
The installation, electrical connection and first operation of this appliance should be carried out by a qualified
installer.
The company does not accept liability for failure of any goods supplied which accor-dance with the
manufacturer‘s instructions.
3.1 Environment and recycling
Recycling of obselete appliances
Appliances with this label must not be disposed off with the general waste. They must be collected separately
and disposed off according to local regulations.
15

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw AEG SK 204 T bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van AEG SK 204 T in de taal/talen: Nederlands, Duits, Engels, Frans als bijlage per email.

De handleiding is 3,81 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info