17
SB2E 850 RS SB2E 1010 RS SB2E 1200 RST
..........850 W ...................1010 W .....................1200 W
..........425 W .....................505 W .......................505 W
........1350 min
-1
............0-1450 min
-1
............. 0-1450 min
-1
........3200 min
-1
............0-3400 min
-1
............. 0-3400 min
-1
..........800 min
-1
.................980 min
-1
.................1150 min
-1
........2000 min
-1
...............2400 min
-1
.................2700 min
-1
......32000 min
-1
.............37600 min
-1
...............43200 min
-1
.......51/28 Nm ................54/30 Nm ..................56/32 Nm
............20 mm .....................20 mm ......................22 mm
............22 mm .....................24 mm ......................24 mm
............13 mm .....................16 mm ......................16 mm
............40 mm .....................40 mm ......................45 mm
........ 1-13 mm ..................1-13 mm .................. 1-13 mm
....1/2"x20 ...................1/2"x20 ................... 1/2"x20
............43 mm .....................43 mm ......................43 mm
...........2,9 kg ......................3,1 kg ........................3,1 kg
..............7 m/s
2
......................7 m/s
2
.......................7 m/s
2
..........101 dB (A) ..............101 dB (A) ................101 dB (A)
..........114 dB (A) .............. 114 dB (A) ................114 dB (A)
ENGLISH
TECHNICAL DATA
Nominal power output ..................................................................
Rated output .................................................................................
No-load speed, 1st gear ...............................................................
No-load speed, 2nd gear ..............................................................
Speed under load max., 1st gear .................................................
Speed under load max., 2nd gear ................................................
Rate of percussion under load max. .............................................
Static jamming moment*, 1st gear/2nd gear ................................
Drilling capacity in concrete ..........................................................
Drilling capacity in brick and tile ...................................................
Drilling capacity in steel ................................................................
Drilling capacity in wood ...............................................................
Drill opening range .......................................................................
Drive shank ..................................................................................
Chuck neck diameter ....................................................................
Weight without cable ....................................................................
Typical weighted acceleration in the hand-arm area ....................
Typical A-weighted sound levels:
Sound pressure level .................................................................
Sound power level .....................................................................
SAFETY INSTRUCTIONS
Please pay attention to the safety instructions in the attached
leaflet!
Appliances used at many different locations including open air
must be connected via a current surge preventing switch.
Always wear goggles when using the machine. It is
recommended to wear gloves, sturdy non slipping shoes and
apron.
Sawdust and splinters must not be removed while the machine
is running.
Always disconnect the plug from the socket before carrying out
any work on the machine.
Only plug-in when machine is switched off.
Keep mains lead clear from working range of the machine.
Always lead the cable away behind you.
Always use the auxiliary handle, even if the machine has a
safety clutch since this safety clutch only engages when the
machine blocks with a jerk.
When working with large drill diameters, the auxiliary handle
must be fastened in a right angle with the main handle (see
illustrations, section „Twisting the handle“).
Do not use diamond core drills on hammer mode.
When working in walls ceiling, or floor, take care to avoid
electric cables and gas or waterpipes.
SPECIFIED CONDITIONS OF USE
The electronic drill/screwdriver can be universally used for
drilling, percussion drilling, screwdriving and cutting screw
threads.
Do not use this product in any other way as stated for normal
use.
MAINS CONNECTION
Connect only to single-phase a.c. current and only to the
system voltage indicated on the rating plate. It is also possible
to connect to sockets without an earthing contact as the design
conforms to safety class II.
EC-DECLARATION OF CONFORMITY
We declare under our sole responsibility that this product is in
conformity with the following standards or standardized
documents. EN 50144, EN 55014-1, EN 55014-2, EN 61000-3-
2, EN 61000-3-3, in accordance with the regulations 98/37/EC,
89/336/EEC
Volker Siegle
Manager Product Development
MAINTENANCE
The ventilation slots of the machine must be kept clear at all
times.
If the machine is mainly used for percussion drilling, regularly
remove collected dust from the chuck. To remove the dust hold
the machine with the chuck facing down vertically, and
completely open and close the chuck. The collected dust will
fall from the chuck. It is recommended to regularly use cleaner
for the clamping jaws and the clamping jaw borings.
Use only AEG accessories and spare parts. Should
components need to be exchanged which have not been
described, please contact one of our AEG service agents (see
our list of guarantee/service addresses).
If needed, an exploded view of the tool can be ordered. Please
state the ten-digit No. as well as the machine type printed on
the label and order the drawing at your local service agents or
directly at: AEG Elektrowerkzeuge, Max-Eyth-Straße 10,
D-71364 Winnenden, Germany.
SYMBOLS
Always disconnect the plug from the socket
before carrying out any work on the machine.
Accessory - Not included in standard
equipment, available as an accessory.
Wear ear protectors! Measured values determined according to EN 50 144.
The data stated above apply for models with 230 - 240 V. In case of deviating mains voltage, the data stated on the rating plate are
applicable.
* Measured according to AEG norm N 877318