EN
of electric power). This way, heat pump is able to extract energy from heat sources existing in its environment
without “expenditure”, depending on the type and availability of the heat sources.
HB300(C) heat pump water heater extracts heat from stuffy internal air to be refreshed, thus it adds to
the efficiency increase of water heating. It is possible to select among several different configurations to use
environmental air, which provides multilateral application of the appliance besides different operational
conditions.
HB300(C) heat pump water heater has been planned and manufactured pursuant to specifications on the
energy performance of buildings. The appliance ensures more rational energy use and leads to savings in the
operational costs. As opposed to other alternative systems used to produce sanitary hot water, heat extraction
from free energy sources definitely reduces environmental effects of emissions into the atmosphere.
2.2. Operation explanation
According to the facts mentioned above, the “energetic capacityof heat
pump is based on heat transfer through heat extraction from free source (in this
case, it is the environmental air) with lower temperature than the material to be
heated (in this case, it is the water in the tank of the water heater). Electric
power is required for the operation of the compressor (that leads to change of
state of matter of the cooling fluid within the cooling circuit), thus for the
transfer of heat energy. Cooling fluid passes along a closed hydraulic circuit
where the fluid changes into liquid or gaseous state of matter in connection with
its temperature and pressure. The main elements of the hydraulic circuit (Figure
2.2-1) are the following:
1 compressor, which ensures cycle running through increasing the
pressure and the temperature of the cooling fluid (which has a gaseous state of
matter in this cycle).
2 first heat exchanger located in the water tank of the water heater:
heat exchange between the cooling fluid and the sanitary water to be heated up
is produced on its surface. As in this phase, the state of matter of the warm
cooling fluid changes and it condenses into liquid while transferring its heat to
the water, this heat exchanger is defined as condenser.
3 expansion valve: it is an equipment through which the cooling fluid
passes just when its pressure and temperature are reducing, following the
expansion of the liquid perceivably as a result of pipe cross-sectional area
increase above the valve.
4 second heat exchanger located in the upper part of the water heater,
which surface has been increased by fins. The second heat exchanger performs heat exchange between the
cooling fluid and the environmental air drifted artificially by either the free source or by a special fan in a
proper way. As in this phase, the cooling fluid evaporates and extracts heat from the environmental air, this heat
exchanger is defined as evaporator.
As heat energy is able to flow from a higher temperature level to a lower temperature level exclusively,
the temperature of the cooling agent located in the evaporator (4) has to be lower than the environmental air
acting as free source, in the same time, in order to transfer heat, the cooling agent located in the condenser (2)
has to possess a temperature higher than the temperature of the water to be heated in the tank.
The temperature difference within the heat pump circuit is produced by the compressor (1) located
between the evaporator (4) and the condenser (2) and by the expansion valve (3), due to physical features of the
cooling fluid.
The efficiency of the heat pump circuit can be measured by the coefficient of performance
(COP). COP is the ration of incoming energy into the appliance (in this case, it is the heat transferred to the
water to be heated) to the electric power used (by the compressor and the supporting equipment of the
appliance). COP may change depending from the type of the heat pump and the related operational
circumstances. A value of 3 for COP means, for example that the heat pump transfers 3 kWh to the material to
be heated after 1 kWh electric power used, from which 2 kWh is extracted from the free source. The rated COP
values of HB300(C) heat pump water heater are listed in table 2.10.1 containing technical data.
Figure 2.2.-1.
7

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw ACV HP300 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van ACV HP300 in de taal/talen: Nederlands, Engels, Frans als bijlage per email.

De handleiding is 2,76 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info