User manual Upsilon boiler
These operation instructions describe the functioning and the operating of the
Upsilon boilers. This manual is for the end user. For installation and servicing
there is an installation & servicing instructions manual for the installer.
Read this manual fully before operating the boiler. In case of doubt or errors
contact your installer.
A.O. Smith reserves the right to change the specications and dimensions
without prior notice.
Safety
The device may be operated only by authorized persons who have
been instructed on the operation and use of the device. Improper use
may cause damage to the device and / or to the connected installation.
The appliance is not to be used by children or persons with reduced
physical, sensory or mental capabilities, or lack of experience and
knowledge, unless they have been given supervision or instructions.
Children being supervised are not to play with the appliance.
Work on the boiler must be carried out by a competent person, (Ref:
Gas Safe Register) using correctly calibrated instruments with current
test certication. When replacing parts use only A.O. Smith Service
parts. Contact details for A.O. Smith can be found on the back page
of this manual.
In case you smell gas:
- No naked ames! Do not smoke!
- Do not operate electrical switches for lights or any other appliance
- Do not use a telephone
- Turn off gas supply at meter
- Open windows and doors
- Notify any persons in the building and leave the building at once
- Call Gas company or installer only when outside the building
Protection for corrosion
Do not use any sprays, chlorine containing agents, solvents, paint etc. around
the boiler or around the air intake supply entrance of the boiler. These substan-
ces have negative inuences on the boiler and can lead to corrosion resulting
in failure of the boiler.
Checking the water pressure
Check the water pressure in the central heating installation regularly.
Use only potable water for lling.
Additives only after clearance by A.O. Smith.
Contact your installer in case of doubt.
Description of the boiler
The Upsilon boiler is a room sealed, condensing and modulating central heating
boiler and meets the European requirements (CE). A declaration of conformity
is available on demand from the supplier.
The efciency of the boiler is very high and the radiation convection and standby
losses very low. The emission of noxious substances is far below the xed
standards so the boiler meets the requirements of today.
If changes are made to the boiler construction the boiler no longer complies
with the CE requirements.
Information and operation of the boiler
Screen User manual
T3
DHW
230V~
AC
230V
out
230V~
AC
230V
out
L
N
L
N
L
N
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 1 2 3 4 5 6 7 8
NN
L
N
L
P3
Error
Heat
demand
LPG
On/Off
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
T10
End
switch
Blocking
Switch
Open-
Therm
LWCO
0-10Volt
230V Pump / 3-WV.230V Damper230V DHW pump230V out230V~ AC
T4
Out
On/Off
L
MBoiC
Keyboard Main switch
Screen
The LCD screen is backlit. The light is activated by pushing one of the buttons
There are 2 light colours available. The various colours indicate the following:
Blue Basic level
Red Problem display
Having pressed the last button, the screen light stays on for 2 minutes.
Screen explanation
9 10 11 12 13
1 5
2 6
3 7
4 8
1. CH-program active
2. DHW-program active
3. Clock program active (CH and/or DHW)
4. Pump continuously active or pumps active when frost protection
is active
5. Boiler off at:
outside temperature > T-day (when day temperature is active)
or > T-night (when night temperature is active)
6. System pump on
7. Burner on.
Starts ashing during ignition, continuous when burner is on.
8. Chimney sweep function (100% power for emission measurement)
. .. 9. Boiler address:
1 = Cascade Master
2..8 = Cascade Slaves
10. Identication burner inside boiler
11. Night temperature active
12. Day temperature active
13. 2 text lines with 8 characters each
The operational status, messages and possible errors are displayed
here.
Operational status
- Standby Standby. Boiler is ready for operation.
- Vent.Phase Ventilation stage
- Ignition phase Ignition stage
- Burner lit CH Burner active for heating
- Burner lit DHW Burner active for hot water
- CH T > Tset Burner off on account of too high ow temperature CH
- Overrun CH Overrun time pump over CH
- Overrun DHW Overrun time pump over DHW
- Service Boiler needs maintenance. Contact installer
- Frost Burner active for frost protection
Explanation keyboard
Value increase / change
Emission Back / correction
measurement
Backward Forward
Reset* Conrm selection
Value decrease / change
* Reset
Reset only functions in case of an Error or certain Messages. If reset is
rapidly pressed over a short period of time, the device will block comple-
tely. Only loss of power (main switch) will restart the device completely.
Recommendation: contact your installer and inform them about the fault and
give them the number code.
The main switch is located on the right hand side of the keyboard. This switch
controls the 230V power supply.
Standard read-out
Standard read-out: Good
we 10:17
Good indicates that the boiler operates normally (burner on
or off)
we 10:17 indicates the actual day and time.
The standard read-out offers 3 information screens.
Switching to different screen can be found using the + or -
button.
1. “Good”-read-out Good with actual day and time
(see above)
2. Operational status Refer to the explanation of texts
at the top of this page
3. Technical read-out Actual water ow
temperature. (T1 in °C)
and water pressure
(P in bar).
See other side
R
OK
-
+
R
OK
-
+
Standby
Good
we 10:17
20.0 °C
1.65 bar
OK
-
+
OK
-
+
User manual
8G.52.91.03 / 04.13 Changes reserved. E.&O. E.
0310 384
A B C D
E F G H
A.O. Smith UK, Unit B8 Amstrong Mall,
Southwood Business Park, Farnborough, Hampshire GU14 0NR
www.aosmith.co.uk
“A.O. Smith Water Heaters” is a trading name of Advance Services (Sales) Ltd. Reg.
Basic settings
With the illumination switched off, rst press on one of the buttons to switch the illumination on and then continue with the setting. Having pressed the last button,
the illumination will switch off after 2 min.
Menu structure at Basic level
Good
Operational status Basic setting Timeprog. options Param Mode Info
Tech. Read-out
CH prog Set date and time Boiler param Cascade
DHW prog Timeprog. CH Other
Pump prg. Timeprog. DHW
Timeprg. CH
Timep. DHW
CH temp
DHW temp
Units
Language
Restore Defaults
In the table below you nd all sub settings of each parameter.
Water pressure
When the screen shows ‘FILL’ the water pressure is too low. Press, if necessary
the + or - button to read out the water pressure. Please contact your installer/
supervisor to check the installation and top up.
Turning the programs on or off
Proceed as follows:
(Switch on the main power supply switch).
From the standard blue illuminated screen:
1. Press the right arrow button:
Screen displays: Basic settings;
2. Press OK;
3. Press the right arrow button:
Screen displays: CH prog off/on;
4. Press the + (on) or - (off) key:
Screen displays: CH prog on or off;
5. Press OK;
6. Repeat procedure from point 3 onward.
This switches off the functions DHW prog. and
Pump prg. respectively.
7. Press the return button to return to the standard display.
Depending which program is selected the corresponding
symbol will be shown in the display.
In some cases it might be necessary to put the complete boiler out of operation.
The boiler is put out of operation by switching off the three functions (
,
and/or ). The frost protection will remain active. Leave gas supply open.
A.O. Smith recommends leaving the power switch switched on to ensure that the
boiler pump(s) and three-way valve (if available) are automatically activated to
prevent them from getting stuck.
If your heating system is not being used during periods of frost we
advise you isolate the power and drain the boiler and the system. In
this case: close the gas valve.
Error, maintenance and warranty
If a fault is detected the boiler will be blocked. This will be reected, with an E
for Error, a B for Blocking or M for Message and a number code on the display.
You can try to reset the boiler by pressing the Reset key once. If the problem
remains please contact your installer and inform them about the fault and give
them the number code.
If, on the screen the message “Service” appears, the installer must perform maintenance according to the installation and service manual. Please contact your installer.
We advise you to obtain a service contract with your installer for regular maintance and adjustment to keep your boiler safe and in good condition.
If you discover any leaks from the boiler contact your installer.
The casing of the boiler consists of metal and plastic parts which can be cleaned with a normal non abrasive cleaning agent.
Important!
It is in your own interest to register your warranty, visit the website www.aosmithinternational.com/content/product-registration and ll in the Pro-
duct Registration Form. Registering the boiler gives the owner of the boiler supplied by A.O. Smith Water Heaters the right to the warranty which
denes the commitments of A.O. Smith Water Heaters to the owner. You can nd the warranty conditions in the Installation and Service Manual
which is supplied with the boiler.
With the arrow buttons
you can go through the
different chapters.
Press OK to select or to
conrm a change.
With the + and - button
you can increase or
decrease a selected
value.
Back to previous screen
or standard read out:
Press this ‘return-button’.
Basic settings Basic settings
PARA
factory
setting
Description Range
CH prog off CH-program on/off
DHW prog off DHW-program on/off
Pump prg off Pump program (frost protection) on/off
Timerpr CH off Clock program CH on/off
Timerp DHW off Clock program DHW on/off
CH temp 90
Adjusted maximum flow temperature in °C
(only active with connected outdoor sensor & P101=0)
10-90
DHW temp 65 Adjusted maximum DHW temperature in °C (only visible when DHW is activated) 10-80
Units SI Selection possibility units SI=Europe, Imp(erial)= USA SI/Imp
Language GB Language selection
GB, NL, I, D, F,
PL, TR, DK, E
Restore defaults Reset of the factory settings (dependant of selected level)
Timeprog options Clock program options
PARA
factory
setting
Description Range
Set date and time
Set Time 00:00 Actual time setting in hours and minutes
Set Date DD-MM-YY Actual date setting day-month-year
Daylight saving Europe Zone for daylight saving Off-Eur-USA
12/24hrs 0-24h 12-hour (AM/PM) or 24-hour display AM/PM-24h.
Date format DD-MM-YY Reproduction of date display (DD-MM-YY, MM-DD-YY, YY-MM-DD)
Time prog CH (only visible when NOT OpenTherm or 0-10V)
Day temp T-day 20
Day temperature according heating line in °C
(if outdoor sensor is NOT connected: max flow temp.)
10-30
(10-90)
Night temp T-night 15 Night temperature according heating line (Eco) in °C 10-30
Select Preset Preset 1 Choice for the preselected time programm CH 1 or 2
Adjust Timeprog
mo1 off
03:00
See table time programs CH
It is possible to select 4 switch moments (steps of 30 min.) per day.
Choice: day temperature, night temperature, off, - - -
Copy function to next day: after switch moment 4.
Store Preset Store of the adjusted time program for CH
Timepr DHW (only visible when NOT OpenTherm)
Select Preset Preset 1 Choice for the preselected time programm DHW 1 or 2
Adjust Timeprog
mo1 off
03:00
See table time programs DHW
It is possible to select 4 switch moments (steps of 30 min.) per day.
Choice: on, off, - - -
Copy function to next day: after switch moment 4.
Store Preset Store of the adjusted time program for DW
Param Mode Parameter chapter
PARA
factory
setting
Description Range
Boiler param
Boiler parameters
P132 1 Pump continuously 1-2
1:Unit
p
um
p
P1
2 Unit
p
um
p
P1 and installation
p
um
p
P
3
Info Information
Cascade
Information of cascade system
T3 xx.x°C DHW temperature T3 in external cylinder in °C (if connected and P100 is selected for DHW)
T4 xx.x°C Outdoor temperature T4 in °C (if connected)
T10 xx.x°C Temperature T10 sensor in low velocity header in °C
Boiler
Information of the boiler
T3 xx.x°C DHW temperature T3 in external cylinder in °C (if connected and P100 is selected for DHW)
Others
Stand-by xx h Number of hours stand by
Burn. On xx h Number of running hours with burner on
Service xx h Number of running hours to go for maintenance interval
Ignition xx Number of times ignition
Faults xx Number of times in error
Basic
Settings
CH prog
off
CH prog
on
CH DHW Pump
Remark: Depending which
parameter settings are set, some
options will not be displayed.
1

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw A.O. Smith Upsilon UB-70 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van A.O. Smith Upsilon UB-70 in de taal/talen: Engels als bijlage per email.

De handleiding is 1,01 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

Andere handleiding(en) van A.O. Smith Upsilon UB-70

A.O. Smith Upsilon UB-70 Aanvulling / aanpassing - Nederlands - 2 pagina's

A.O. Smith Upsilon UB-70 Gebruiksaanwijzing - Nederlands - 2 pagina's

A.O. Smith Upsilon UB-70 Installatiehandleiding - Nederlands - 72 pagina's

A.O. Smith Upsilon UB-70 Installatiehandleiding - English - 68 pagina's

A.O. Smith Upsilon UB-70 Aanvulling / aanpassing - English - 2 pagina's


Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info