To remove the front panel, undo the screws
using the tool provided on each side of the base
of the front panel. The panel can then be
removed (see illustration below).
A Temperature control.
B System pressure gauge (External System
models only).
C Boiler mode indicator.
D Mode switch.
E Reset button - flue thermostat.
F Reset button - heating.
G Lockout indcator/reset button (is located
on the burner control box see ‘reset button
locations’ below).
Reset Button Locations
All Models
Remove front panel to access
all reset buttons.
The Flue Thermostat Reset
Button (E) and Heating
Thermostat Reset Button (F) are
located beneath the boiler
control panel.
The Lockout Reset Indicator/
Button (G) is located on the
burner control box which is
situated on the burner at the
base of the appliance.
CONTROLS