5110326C_OI-II_Webasto Live 15
The Webasto Live charging station also meters
the plug-in cycles of the charge coupling for ser-
vice purposes and after 10,000 plug-in cycles, dis-
plays a note on the web interface that an electri-
cian needs to inspect the plug contacts on the
charge coupling for any signs of wear. If any signs
of wear are discovered, the electrician must re-
place the affected charging cables with genuine
Webasto spare parts.
Do not attach extension cables or adapters to the
charging cable.
Remove the charging cable by pulling on the
charging coupling only.
Never clean the charging station with a high-pres-
sure cleaner or similar device.
Switch off the power supply before cleaning the
charging sockets.
The charging cable must not be subjected to any
strain during use.
Ensure only persons who have read these operat-
ing instructions have access to the charging sta-
tion.
2.3 Safety information for installation
Installation and connection of the charging sta-
tion must only be carried out by an electrician.
Only use the supplied installation material.
The Webasto Live safety concept is based on a
power supply system that is earthed at all times.
The electrician must ensure this requirement dur-
ing installation.
Do not install the charging station in an explosion
sensitive area (EX zone).
Install the charging station in such a way that the
charging cable does not block any passageways.
Do not install the charging station in areas subject
to ammonia or air containing ammonia.
Do not install the charging station in a location
where falling objects (e.g. extension reel or tyres)
can damage the charging station.
The charging station is suitable for use indoors as
well as outdoors.
Do not install the charging station in the vicinity of
water jets, e.g. car wash installations, high pres-
sure cleaners or garden hoses.
Protect the charging station against damage
caused by sub-zero temperatures, hail or similar.
The charging station is suitable for use in areas
without access restrictions.
Protect the charging station from direct sunlight.
The charging current may be reduced at high tem-
peratures or charging may be disabled completely.
The installation location of the charging station
should be selected such that vehicles cannot inad-
vertently collide with it. Protective measures must
be implemented if the possibility of damage can-
not be ruled out.
Do not place the charging station into operation if
it is damaged during installation. A replacement
will be required.
2.4 Safety information for electrical
connection
Comply with the locally applicable requirements
pertaining to electrical installations, fire protec-
tion, safety regulations and escape routes at the
intended installation location.
Each charging station must be protected with its
own line circuit breaker and residual current circuit
breaker. See chapter6.2, "Criteria for the elec-
trical connection" on page 17.
Make sure that the electrical connections are de-
energised before connecting the charging station
to the power supply.
Make sure that the correct supply cable is used for
the power connection.
Do not leave the charging station unattended
with the cover open.
Register with the power supply company as re-
quired.
2.5 Safety information for initial startup
Initial startup of the charging station must be car-
ried out only by an electrician.
Prior to initial startup, the electrician must check
that the charging station has been connected cor-
rectly.
Do not connect a vehicle during initial startup of
the charging station.
Before startingup the charging station, check the
charging cable, charging coupling and the char-
ging station for visible damage. The charging sta-
tion must not be started up if it is damaged or if
the charging cable/charging coupling is damaged.
3Unit description
Fig.1
These operating and installation instructions describe the
Webasto Live charging station. The exact unit description
is indicated on the type label of the charging station.
3.1 Description of data interface connections
Fig.2
Legend
USB-A
Modbus (RS 485) external
Micro SIM-slot
RJ 45 (LAN)
USB-B
With the cover open, the data interfaces can be found on
the left-hand side in the connection area. This area is
separated from the power supply area.
3.1.1 USB type A
This connection is used in host mode for a USB stick for
software or configuration updates. This connection sup-
ports the 5 V power supply up to maximum 100 mA.
3.1.2 Modbus
The data connection to a primary electricity meter can be
established for advanced power management. (see on-
line configuration instructions: https://webasto-
charging.com/documentation)
27

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Webasto Live bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Webasto Live in de taal/talen: Nederlands, Duits, Engels, Italiaans, Spaans als bijlage per email.

De handleiding is 7.58 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Andere handleiding(en) van Webasto Live

Webasto Live Gebruiksaanwijzing - Dansk, Svenska, Norsk, Suomi - 67 pagina's


Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info