The piping can be lead out on the right, left or directly
behind the indoor unit as seen in fig. 1. Please cut off the
pipe hole guards if you are changing the pipe position.
The unit also features alternative guards for more pipe
positioning.
Make sure that the drain pipe is underneath the pipelines.
(Fig.3) (When the drain pipe passes the room interior,
some condensed water might occur to its surfaces if the
humidity is very high).
Tidy up the copper pipes, electrical cables and water
drains and pass them through the wall hole drilled earlier
(fig.2).
Hang the mounting slots of the indoor unit on the wall
mounting bracket making sure is tight in place (fig.3) so
that the hooks at the bottom of the indoor unit match the hooks of the wall mounting bracket
(fig.4)
Notes:
1. The height of the installed unit is recommended to >
200 cm.
2. Either the indoor unit or the outdoor unit can be higher,
but the height difference must comply with a max. 5
metres level difference.
3. Try to avoid bending the pipes as much as possible so
as to avoid possible negative impacts upon the
performances of the unit.
INSTALLATION OF THE OUTDOOR UNIT
Try to move the product to the installation location in its original packaging
As the gravity center of the unit is not at the installation center, special caution should be taken
when using hoisting cables to lift it up
During transport, the outdoor unit must not be tilted to over 45 degrees (also do not store the unit
horizontally.
Use expansion bolts to fix the mounting supports on the wall;
Use bolts and nuts to fix the outdoor unit firmly on the supports and keep on the same level;
If the unit is installed on the wall or at the rooftop, the supports have to be firmly fixed so as to
resist earthquakes or strong wind.
Dimensions for parallel units installations
300mm(1')min