592499
5
Verklein
Vergroot
Pagina terug
1/10
Pagina verder
The SensorLight can be put into operation as soon as
the enclosure has been fitted and the SensorLight
has been connected to the mains power supply.
Putting the light into operation manually at the light
switch turns it OFF after 10 secs. for the calibration
phase. Once calibrated, it is activated for the sensor
mode. It is not necessary to operate the light switch a
second time.
Reach setting (sensitivity)
Reach can be infinitely varied from
3 m to 8 m.
Adjustment control set to:
= minimum reach (3 m)
+ = maximum reach (8 m)
Factory setting: 8 m.
Reach is the term used to describe the diameter of
the more or less circular detection zone produced on
the ground after mounting the SensorLight at a height
of 2.5 m.
Time setting (switch-off delay)
Light ON duration can be infinitely
varied from 5 sec. to 15 min.
Adjustment control set to:
= shortest 'ON' time (5 sec.)
+ = longest 'ON' time (15 min.)
Factory setting: 5 sec.
Any movement detected before this time elapses will
re-start the timer. The shortest time setting is recom-
mended when adjusting the detection zone and per-
forming a functional test.
Note: After the light switches
'OFF', it takes approx.
1 sec. before it is able to start detecting movement
again. The light will only switch
'ON' in response to
movement once this period has elapsed.
Twilight setting (response threshold)
The response threshold can be
infinitely varied from 2 – 2000 lux.
Adjustment control set to:
= Night-time operation (2 lux)
= daylight operation (2000 lux)
Factory setting: 2000 lux
When adjusting the detection zone and performing
the walk test in daylight, the control must be set
to .
Functions
- 9 -
Functional Warranty
This STEINEL product has been manufactured with
great care, tested for proper operation and safety in
accordance with applicable regulations and then sub-
jected to random sample inspection. STEINEL guar-
antees that it is perfect condition and proper working
order. The warranty period is 36 months, starting on
the date of sale to the consumer. We will remedy
defects caused by material flaws or manufacturing
faults. The warranty will be met by repair or replace-
ment at our own discretion. The warranty shall not
cover damage to wear parts, damage or defects
caused by improper treatment or maintenance.
Further consequential damage to other objects is
excluded.
Claims under the warranty will only be accepted if the
unit is sent fully assembled and well packed complete
with a brief description of the fault, a receipt or
invoice (date of purchase and dealer's stamp) to the
appropriate Service Centre.
Repair Service:
Our Customer Service Department will
repair faults not covered by warranty
or after the warranty period. Please
send the product well packed to your
nearest Service Centre.
Declaration of conformity
This product complies with
- Low Voltage Directive 2006/95/EC
- EMC Directive 2004/108/EC
- RoHS Directive 2002/95/EC
- R&TTE Directive 1999/05/EC
Installation
Important: Make sure the installation site is
not sub-
ject to
vibration.
Connecting a dimmer will result in damage to the
SensorLight.
Please note that the light must be protected by a 10 A
circuit breaker.
1. Hold enclosure against the wall/ceiling and
mark drill holes, paying attention to any existing
wiring in the wall/ceiling.
2. Drill the holes, insert wall plugs (6 mm dia.).
3. Pierce sealing plug for power supply lead.
4. Pass power supply leads through.
5. Screw enclosure into place.
6. Connecting the mains power supply lead (see fig.).
The mains power supply lead is a 3-core cable:
L = phase conductor (usually black or brown)
N = neutral conductor (usually blue)
PE = protective earth conductor (green/yellow)
If you are in any doubt, identify the conductors using
a voltage tester; switch
'OFF' the current again.
Connect the phase conductor (L) and neutral con-
ductor (N) to the terminal block. Insulate any PE pro-
tective earth conductor with adhesive tape.
Technical specifications
Dimensions (HxWxD): 300 x 300 x 110 mm
Material: Aluminium (heat sink),
polycarbonate (base/diffuser)
Mains voltage: 230 – 240 V, 50 Hz
Output: 16 W LED / 460 lm
Colour temperature: 3200 kelvin (warm white)
LED life expectancy: 50.000 hours
HF-system: 5.8 GHz
Angle of coverage: 360° with 160° aperture angle also through glass, wood and stud walls
Detection reach: 3 m – 8 m all round
Twilight setting: 2 – 2000 lux
Time setting: 5 sec. to 15 min.
IP rating: IP 20
Protection class: II
Power consumption: approx. 0.9 W
Temperature range: -10° C to +50° C
- 8 -
7. Set functions , , .
8. Fit glass shade and turn clockwise to secure it in
place.
Surface wiring:
Surface wiring can be carried out as shown in
diagram I on page 2.
GB
Ø 3 m – 8 m dia.
5 sec. - 15 min.
+
+
2 – 2000 lux
5

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Steinel RS LED D1 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Steinel RS LED D1 in de taal/talen: Duits, Engels, Spaans, Pools als bijlage per email.

De handleiding is 0,71 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info