593381
7
Verklein
Vergroot
Pagina terug
1/8
Pagina verder
Charging the battery
Only use the charging station shown under
10
. This is the only
charging station designed for the li-ion rechargeable battery used
in your hot air tool.
Note: The rechargeable battery is supplied partially charged. To
ensure full power output, fully charge the rechargeable battery in
the charger prior to first-time use.
The lithium-ion rechargeable battery can be recharged at any
time without shortening its lifespan. Interrupting the charge cycle
will not damage the rechargeable battery.
The li-ion rechargeable battery is protected from exhaustive dis-
charge by "Electronic Cell Protection (ECP)". When the battery is
run down, the hot air tool is shut down by protective circuitry:
Note: After the hot air tool automatically shut down, do not press
the ON/OFF switch any more. This may damage the rechargeable
battery.
To remove the rechargeable battery
14
:
Push the rechargeable battery towards the base of the hot air
tool while pressing the release button.
Pull the rechargeable battery from the hot air tool so that the
STEINEL logo becomes visible.
Removing rechargeable battery
The rechargeable battery
14
has two locking stages that are
designed to prevent the rechargeable battery from falling out
after accidentally pressing the rechargeable-battery release button
9
. While the rechargeable battery is inserted in the hot air tool,
it is held in position by a spring.
Inserting rechargeable battery
From the front, slide the charged battery
14
into the base of the
hot air tool. Push the rechargeable battery all the way into the
base so that the STEINEL logo is no longer visible and the
rechargeable battery is securely locked in place.
Rechargeable-battery temperature below 0 °C
and over 45 °C
The red LED indicator
12
lights up permanently
to signalise that the rechargeable battery is out-
side the fast-charging temperature range of 0 °C
– 45 °C. As soon as the permissible temperature
range is reached, the charger automatically
switches over to fast charge mode. If the re-
chargeable battery is outside the permissible charging tempera-
ture range, the red LED on the rechargeable battery lights up
when inserted into the charger.
Charging not possible
Any other fault affecting the charge cycle is
indicated by flashing red LED indicator
12
.
The charge cycle cannot be started and the
rechargeable battery cannot be charged.
This may be because:
the battery contacts are soiled.
Action: Clean the contacts (e.g. by fitting and removing the
rechargeable battery several times) or, if necessary, replace
the rechargeable battery.
The rechargeable battery is faulty because there is a break
in the wiring inside the rechargeable battery (single cells).
Action: Replace the rechargeable battery.
Operation
The tool is switched ON and OFF at the 3-stage switch on the
front of the grip. The distance from the object you are working on
depends on material and intended method of working. Always try
out airflow and temperature on a test piece first. Using the attach-
able accessory nozzles (see accessories) the flow of hot air can
be controlled with maximum precision. A small quantity of smoke
may occur the first time the tool is used. Switch the tool to the
"0" position by pressing switch
4
. Take care when changing
hot nozzles! When using the hot air tool in the self-resting pos-
ition, make sure it is standing on a stable, non-slip and clean
surface.
LED Capacity
3 x green permanently lit ≥ 2/3
2 x green permanently lit ≥ 1/3
1 x green permanently lit < 1/3
1 x green flashing reserve power
Battery charge indicator
The three green LED's of the rechargeable-battery charge indica-
tor
17
show the charging condition of the rechargeable battery
14
. For safety reasons, the charging condition can only be
requested when the electric power tool is idle.
Press button
15
to display the charging condition (also possible
with the rechargeable battery removed). The charge indicator
goes out automatically after approx. 5 seconds.
If none of the LED's light up after pressing button
15
, the
rechargeable battery is faulty and must be replaced.
While charging, the three green LED's on the rechargeable bat-
tery light up in succession and briefly go out. The rechargeable
battery is fully charged when the three green LED's are perma-
nently lit. The three green LED's go out again about 5 minutes
after the rechargeable battery has been fully charged.
The rechargeable battery features an NTC temperature monitor
that only allows it to be recharged within a temperature range of
between 0 °C and 45 °C. This gives the rechargeable battery a
long life.
Temperature monitoring indicator
The red LED temperature monitoring indicator
16
signalises that
the rechargeable battery or the electronics of the hot air tool (with
rechargeable battery fitted) are not within the optimum tempera-
ture range. In this case, the hot air tool will not work or fail to
work at full performance.
Rechargeable battery temperature monitor:
The red LED
12
permanently lights up after inserting the re-
chargeable battery into the charger: The rechargeable battery
is outside the charging temperature range of 0 °C to 45 °C
and cannot be charged.
The red LED
12
flashes on pressing button
15
or ON/OFF
switch
4
(with rechargeable battery inserted): The recharge-
able battery is outside the operating temperature range of
–10 °C to +60 °C. At a temperature of over 70 °C, the
rechargeable battery switches off until it returns to the opti-
mum temperature range.
The LED light is lit when the tool is switched on. In addition
to illuminating the area you are working on, it also serves as
a "tool ON" indicator light.
LED light
Setting 1 is the cold-air stage, delivering a temperature of
approx. 40 °C. Use the cold-air function for drying paint, cooling
workpieces or to cool the nozzle before changing an accessory
attachment.
Setting 2 without nozzle delivers a temperature of 400 °C.
A temperature of 500 °C is reached by fitting the 7 mm reduction
nozzle.
Setting the temperature
The integrated ring can be used for
hanging the tool.
Attention: max. pulling force = 150 N
Hanging hook
6
- 13 -- 12 -
LED indicators
12
and
13
not lit
LED indicators
12
and
13
do not light up after plugging into the
power socket. This may be because:
The charger is not plugged in (properly).
Action: Push the plug into the power socket (all the way).
Power socket, cord or charger are faulty.
Action: Check the mains voltage and have the charger in-
spected by a customer service centre authorised for STEINEL
power tools.
Note
The charger may heat up when used continuously or for
several charge cycles in uninterrupted succession. This is no
cause for concern and does not indicate a technical fault.
A significantly shorter operating time after charging indicates
that the rechargeable batteries are worn out and must be
replaced.
Rechargeable battery cooling (Active Air Cooling)
The fan controller integrated in the charger monitors the tempera-
ture of the rechargeable battery inserted in it. If battery tempera-
ture is above 30 °C, it is cooled by a fan to optimum charging
temperature. The fan makes a ventilating noise when switched
on.
When the fan is not running, the rechargeable battery is either
inside the optimum temperature range or the fan is faulty. In this
case, the rechargeable battery will take longer to charge.
Using the BHG 360 Li-Ion hot air tool
7

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Steinel BHG 360 Li-Ion bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Steinel BHG 360 Li-Ion in de taal/talen: Alle talen als bijlage per email.

De handleiding is 1,82 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info