515947
15
Verklein
Vergroot
Pagina terug
1/88
Pagina verder
E-13
ENGLISH
INDOOR TEMP.
OUTDOOR TEMP.
COOLING
upper limit 32˚C 46˚C
lower limit 21˚C –10˚C
HEATING
upper limit 27˚ C 24˚C
lower limit –15˚C
The built-in protective device may prevent the unit
from operating when used out of this range.
Condensation may form on the air outlet if the unit
operates continuously in the COOL or DRY mode
when humidity is over 80 percent.
ADDITIONAL NOTES ON
OPERATION
OPERATING TEMPERATURE RANGE
BEFORE CALLING FOR
SERVICE
The following conditions do not denote equip-
ment malfunctions
UNIT DOES NOT OPERATE
The unit will not operate if it is turned on immediately
after it is turned off. The unit will not operate
immediately after the mode is changed. This is to
protect the internal mechanisms. Wait 3 minutes
before operating the unit.
UNIT DOES NOT SEND OUT WARM AIR
The unit is preheating or de-icing.
ODORS
Carpet and furniture odors that entered into the unit
may be sent out from the unit.
CRACKING NOISE
The unit may produce a cracking noise. This sound
is generated by the friction of the front panel and
other components expanding or connecting due to a
temperature change.
A LOW BUZZING NOISE EMITTED
This is a sound emitted when the unit is generating
Plasmacluster ions.
SWISHING NOISE
The soft, swishing noise is the sound of the refrigerant
owing inside the unit.
WATER VAPOUR
In the COOL and DRY operation, water vapour
can sometimes be seen at the air outlet due to the
difference between the room air temperature and
the air discharged by the unit.
In the HEAT operation, water vapour may ow out
of the outdoor unit during de-icing.
THE OUTDOOR UNIT DOES NOT STOP
After stopping the operation, the outdoor unit will
rotate its' fan for about a minute to cool down the unit.
ODOR EMITTED FROM THE PLASMACLUSTER
AIR OUTLET
This is the smell of ozone generated from the
Plasmacluster Ion generator. The ozone concentration
is very small, posing no adverse effect on your
health. The ozone discharged into the air rapidly
decomposes, and its density in the room will not
increase.
If the unit appears to be malfunctioning, check the
following points before calling for service.
IF THE UNIT FAILS TO OPERATE
Check to see if the circuit breaker has tripped or the
fuse has blown.
IF THE UNIT FAILS TO COOL (OR HEAT) THE
ROOM EFFECTIVELY
• Check the lters. If dirty, clean them.
Check the outdoor unit to make sure nothing is
blocking the air inlet or outlet.
Check the thermostat is proper setting.
Make sure windows and doors are closed tightly.
A large number of people in the room can prevent
the unit from achieving the desired temperature.
Check whether any heat-generating appliances are
operating in the room.
IF THE UNIT FAILS TO RECEIVE THE REMOTE
CONTROL SIGNAL
Check whether the remote control batteries have
become old and weak.
Try to send the signal again with the remote control
pointed properly towards the unit’s signal receiver
window.
Check whether the remote control batteries are
installed with the polarities properly aligned.
Please call for service when OPERATION lamp,
TIMER lamp and/or PLASMACLUSTER lamp on
the unit blink.
WHEN POWER FAILURE OCCURS
This air conditioner has a memory function to store
settings when a power failure occurs.
After power recovery, the unit will automatically re-
start in the same settings which were active before
the power failure, except for timer settings.
If the timers were set before a power failure, they will
need to be re-set after power recovery.
PREHEATING FUNCTION
In the HEAT operation, the indoor fan may not start
for two to ve minutes after the unit is turned on to
prevent cold air from blowing out of the unit.
DE-ICING FUNCTION
When ice forms on the heat exchanger in the
outdoor unit during the HEAT operation, an
automatic de-icer provides heat for about 5 to 10
minutes to remove the ice. During de-icing, the
inside and outside fans stop operating.
After de-icing is completed, the unit automatically
resumes operation in the HEAT mode.
HEATING EFFICIENCY
The unit employs a heat pump that draws heat from
the outside air and releases it into the room. The
outside air temperature therefore greatly affects the
heating ef ciency.
If the heating efficiency is reduced due to low
outside temperatures, use an additional heater.
It takes time to warm up and heat the entire room
because of the forced air circulation system.
BEFORE CALLING FOR
SERVICE
15

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Sharp AE-X7HR bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Sharp AE-X7HR in de taal/talen: Engels als bijlage per email.

De handleiding is 3,68 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info