- Keep the splitting knife guides clean.
(dirt, splinters, bark, etc.)
- Lubricate slide bars with spray oil or grease
Check oil level of hydraulics
Check hydraulic connections and screws
for tightness and abrasive wear. If neces-
sary retighten the screw connections.
When do I change the oil?
First oil change after 50 operating hours, then
always after 250 operating hours.
Check the oil level.
Check the oil level frequently before each start-
up. If the oil level is too low, the oil pump may be
damaged.
Note: The oil level must be checked while the
splitting knife is retracted. The oil dipstick is
located on the splitting column in the ller plug
A (Fig. 5) und is provided with 1 slot. If the
oil level is at the lower end of the dipstick, this
indicates that the minimum oil level has been
reached. If this is the case, the oil must be
relled immediately. The slot indicates the maxi-
mum oil level.
The oil tank is situated in the splitting column
and is lled with high-quality hydraulic oil by the
manufacturer.
Change of the hydraulic oil and the oil lter.
Place a container under the suction hose.
Remove the hose clamp of the pump and pull off
the suction hose. Caution: allow the oil to ow
into the container! Fig. 7
Remove the suction hose completely and by
slightly tilting, allow the remaining oil to drain
into the container.
To change or clean the lter, remove the entire
intake manifold by means of a at spanner
SW41 or pipe wrench! Fig. 7.1
Clean the lter and re-mount with new sealing
tape, item no.: 1607 0333. Connect the suction
hose again and secure with hose clamps.
Remove the ller plug and ll with new hydraulic
oil.
Attention! Make sure that no dirt particles
enter the oil tank.
Dispose of used oil accordingly by taking it
to the local waste oil collection points. It is
prohibited to drain used oil into the soil or to
mix it with waste.
We recommend the following hydraulic oils:
Q8 Haydn 46
Aral Vitam gf 22
BP Energol HLP-HM 22
Mobil DTE 11
Shell Tellus 22
or equivalent.
Do not use other oil grades! The use of other
oil types affects the function of the hydraulic
cylinder.
Only when operated by PTO: change the oil of
the transmission gearing after the rst 35 opera-
ting hours, then after 1,000 operating hours or at
least once per year. Ensure that the connections
of the hydraulic system do not leak.
Hydraulic system
The hydraulic system is a closed system with oil
tank, oil pump and control valve.
The factory-made and completed system must
not be modied or re-engineered.
Check the oil level frequently.
Too low an oil level may damage the oil pump.
Check the hydraulic connections and screws for
tightness frequently – retighten if necessary.
Prior to maintenance and checking procedures,
clean the work space and have appropriate tools
in good condition to hand.
The above-indicated time intervals refer to
normal terms of use; if the machine is exposed
to heavy load, those time intervals decrease
accordingly.
Clean the machine casing, the panels and the
control levers with a soft, dry cloth that you can
moisten a little with a neutral cleaning agent.
Do not use alcohol or benzene since they might
damage the surfaces.
Keep oil and lubrication grease out of the reach
of unauthorised personnel. Read the instruc-
tions on the containers carefully and observe
them strictly. Avoid skin contact and rinse well
after use.
Troubleshooting
In cases of errors not mentioned below, please contact the customer service of the company scheppach.
Error Possible causes Solution Degree of danger
The hydraulic pump does
not run
No voltage Check whether the conductors
have power supply
Danger of an electric shock
This work process must be
performed by a maintenance
electrician.
The thermo-switch of the motor has
turned itself off.
The thermo switch turns on again
when the motor has cooled down.
The motor can be re-started.
The column does not
move downwards
Low oil level Check the oil level and rell Danger of contamination!
This work process can be carried
out by the machine operator.
2-manual shift not correct Check the xing of the levers Risk of being cut!
Dirt in the column guide Clean the column
Motor starts but the
column does not move
downwards
Incorrect rotating direction of the
motor during three-phase current
Check rotating direction of the
motor and shift to correct direction
Incorrect rotating direction can
damage the pump
Maintenance and repairs
All maintenance procedures must be performed
by qualied personnel under strict observation of
the available operating manual.
Prior to each maintenance, all possible
precautions must be taken; turn off the motor
and disconnect the power supply (if necessary,
unplug the power plug). Place a sign on the
machine which explains the outage of the device
“Machine out of service due to maintenance:
unauthorized persons are not allowed to start up
the machine or to remain in close proxim.
23
DGB
23

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Scheppach OX 7-1020 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Scheppach OX 7-1020 in de taal/talen: Duits, Engels, Frans als bijlage per email.

De handleiding is 3.51 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info