Important! As soon as your vacuum cleaner starts to malfunction, and before performing any checks:
• Stop the appliance by pressing the Start/Stop switch .
• Unplug the appliance.
AMBIA will not start.
• The product is not connected to the mains . . . . . . . . . Check that the product is correctly plugged in.
Check the fuse and your mains supply circuit breaker.
AMBIA does not suck.
• Either a tool or the hose is blocked . . . . . . . . . . . . . . . Unblock the tool or the hose.
AMBIA sucks less effectively, makes more noise than usual, and whistles.
• A tool or the hose is partially blocked . . . . . . . . . . . . . Unblock the tool or the hose.
• The bag is full or blocked by fine dust . . . . . . . . . . . . . Replace the bag or empty the cloth bag.
• The foam filters and microactive filter are full . . . . . . . Clean the foam filters and replace the microactive filter.
• The HEPA filter is full . . . . . . . . . . . . . . . . . . . . . . . . . . Change the HEPA filter.
• The cover is not properly closed . . . . . . . . . . . . . . . . . Check the position of the bag on its support.
Check the position of the bag support.
• The air regulator is open . . . . . . . . . . . . . . . . . . . . . . . Close the air regulator.
• The electronic power selector is in the min. position. . . Increase power using the electronic power selector (except when
vacuuming delicate fabrics).
The dust bag full indicator stays red.
• The bag is full . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Replace the bag or empty the cloth bag.
• The nozzle is difficult to remove . . . . . . . . . . . . . . . . . Open the suction control or reduce its power.
AMBIA stops while vacuuming.
•
The thermal cut-off switch has activated
. . . . . . . . . Clean the motor filter, change the micro-active filter (according to model*)
and replace the bag. Allow the AMBIA to cool down for 30 minutes before
switching on again.
The power cord does not fully retract.
• The cord slows down as it is retracted . . . . . . . . . . . . . Pull out the cord until completely extended and press on the retraction
button .
The dust bag compartment cover will not close.
• The dust bag compartment cover has been
knocked out of place. . . . . . . . . . . . . . . . . . . . . . . . . .Put it back in place by putting the flaps back in their holds.
Your vacuum cleaner no longer diffuses scent.
• There is no more perfume in the ceramic . . . . . . . . . . .Put a few more drops of perfume on the ceramic.
You are pourring some perfume on the ceramic.
•Drops of perfume fall on the product . . . . . . . . . . . . . .Wipe immediatly the vaccuum cleaner with a moist cloth.
If the problem persists take the AMBIA to your nearest Rowenta Approved Service Centre.
Helpline : 0845 602 1454 (UK calls charged at local rate) (01) 47 51947 (IRELAND).
WHAT TO DO IF :