15
When the voltage is below 6.1V, then the transceiver will power
off by itself.
Wired Cloning between two transceivers
Well connected the transmission lines to the both transceivers,
and then power on the subsidiary transceiver.
Rotate the channel selector on the base transceiver to channel
8, then hold and Press “Radio/Monitor/Reception+” key to power
on, (3 seconds later) until the orange light (red light and yellow
light ash simultaneously) ashes which indicates the base trans-
ceiver is in cloning state, then release the button.
When the orange light on the base transceiver ashes, press the
PTT key, the red light on base transceiver ashes, and the yellow
light on subsidiary transceiver ashes, which indicates the base
transceiver is in cloning state. The mutual clone is successful
when the light on base transceiver ashes orange again.
If indicator lights of both two transceivers ashes abnormally in
the process of data transmit, it means replication fail. In that
case, please check and make sure the transmission line is well
connected. And please press the PTT button again to resume
cloning when the indicator light of the base transceiver shines
orange.
If need to clone with more than one transceiver, please turn off
the subsidiary device after cloning nished and then pull out the
transmission cable. And then clone to next transceiver following
steps above.
Please reboot the transceiver to make it work properly after cloning.
3.
1.
2.
3.
4.
5.
6.