770991
15
Verklein
Vergroot
Pagina terug
1/19
Pagina verder
petsafe.com1-800-732-2677 2928
Wire Break Location Test
The following lists identify the common locations where wire breaks occur.
Please inspect these areas for signs of damage.
Wire breaks in the twisted pair are commonly found:
1. At the wire exit point of the house
2. Where the twisted pair of wire enters the ground from the house,
usually caused by string trimmers
3. Where the wires cross sidewalks or driveways due to edging and
string trimmers
4. Around landscaping and flower beds due to digging, or working up
the soil
Wire breaks in the boundary wire are commonly found:
1. In aerated lawns
2. Where the wires cross sidewalks or driveways due to edging and
string trimmers
3. Around landscaping and flower beds due to digging, or working up
the soil
4. At wire splices where gel-filled capsules have not been installed
5. At wire splices without reinforcement knots (15A)
If you still cannot find the break in the boundary wire, there are
2 options for locating it:
Option 1: It is recommended to contact the Customer Care Center to
purchase a wire break locator (15B). The Wire Break Locator detects full
breaks, not partial breaks.
Option 2: Follow the procedure below:
1. Unplug the fence transmitter.
2. Connect both ends of your twisted boundary wire to one loop
terminal on the surge protector.
3. Measure and cut a test wire which is half the length of your total
boundary wire footage.
4. Connect one end of test wire to the other loop terminal on the
surge protector.
5. Locate the halfway point of your boundary and cut the boundary wire.
6. Splice the other end of the test wire to either side of your boundary
wire where you cut it in half.
7. Plug in the fence transmitter, set the mode to mode (B), and check the
loop indicator light. If the loop indicator light is on, you can assume that
the break is in the other half of the boundary wire.
8. If the loop indicator light did not come on, you may assume there is a
break in this portion of the boundary wire. However, there is a small
chance of having more than one break in your system. Be sure to check
both halves of your entire loop.
9. Replace the damaged boundary wire with new boundary wire.
10. Reconnect the boundary wire to the surge protector.
11. Check the loop indicator light. If the loop indicator light is on, test the
system with the receiver collar.
15 A
15 B
Receiver Collar Status Indicators
The receiver collar light and with the alarm tones are used to determine the operational mode, the battery status and the correction level. Refer
to the receiver collar status table below to understand the status lights and tones for the receiver collar. During normal operation, the receiver
collar light will flash every 4 seconds to indicate the battery status as shown in the table below. If your receiver collar has not been moved for
at least 20 seconds, the battery status light will function, but the receiver collar will enter sleep mode to conserve battery life. To wake up the
receiver collar simply pick it up and flip it over or shake it.
Receiver Collar Status Table
Light Status Alarm Tone Condition
While Plugged into the Receiver Charger
Solid red No tone Charge in progress
Solid green No tone Charge complete
No light No Tone Charge failure—contact Customer Care Center
ReadyTest® Startup
(After removing the receiver collar from the charger or after first turning it on)
Off for 1 second No tone Unit is starting the ReadyTest® startup feature
Continuous red, green, or red+green together
(5 seconds) No tone Battery charge status
Flashing red from 1 to 6 times No tone Receiver collar is reporting the
static correction level from 1 to 6
Continuous red 20 seconds ReadyTest® failure;
Unit is not operational—contact Customer Care Center
PerfectFit Test
Flashing red+green together
(every 1 second) No tone Unit is in PerfectFit mode for 90 seconds
after the ReadyTest® startup is completed
Flashing green
(every 1 second)
5 consecutive double tones
for a confirmed fit
PerfectFit mode indicates that the collar is making
true contact with the pet’s skin
Static Correction Level
Flashing red from 1 to 6 times No tone Receiver collar is reporting the
static correction level from 1 to 6
Receiver Activation Status
Fast pulsating green Warning tone Warning tone
Fast pulsating red Duration of the correction Static correction is being delivered
(up to 10 seconds)
Continuous green
(10 seconds) No tone Over Correction Protection feature;
Collar is locked for 10 seconds
Slow blinking green
(every 4 seconds) No tone Collar battery charge 100%–60%
Slow blinking red+green together
(every 4 seconds) No tone Collar battery charge 60%20%
Slow blinking red
(every 4 seconds) No tone Collar battery charge 20% or less;
Charge immediately
15

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Petsafe PIG00-11115 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Petsafe PIG00-11115 in de taal/talen: Engels als bijlage per email.

De handleiding is 3.48 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info