INSTALLATION
29
28
INSTALLATION
Installation
General
When the appliance does not have a
connecting cable and plug, then it may be
connected to the mains only by an approved
installer.
Please note:
The power rating and required mains voltage
are shown on the rating plate at the back of
the oven. Connection should take place
according to national and local regulations.
After installation the wall socket and plug
must be accessible at all times.
To connect the appliance a fixed connection
has to be made. The wire which is coloured
green and yellow must be connected to the
terminal which is marked by the letter E or the
earth symbol or which is coloured green,
or green and yellow. The wire which is
coloured blue must be connected to the
terminal which is marked by the letter N or
which is coloured black. The wire which is
coloured brown must be connected to the
terminal which is marked by the letter L or
which is coloured red. If the input of the
appliance exceeds 3 kW, the appliance has to
be connected to an outlet with a rated current
exceeding 13 Amp.
Electrical connection
230 V -50 Hz
■ The appliance should always be earthed.
Uase good quality cable for connecting e.g.
H05RRF, 1,5 or 2,5 mm
2
, with 3 or 5 cores,
depending on the regulations.
With following colour code:
brown = phase L
blue = phase N
green/yellow = earth ( )
black= neutral or phase
Depending upon the wiring diagram, you
can use the black cores for neutral or a
phase.
The cable must have a plug suitable for a
nominal load of at least 15 A.
If you want to make a fixed connection,
ensure that a multi-pole switch with a
distance between contacts of 3 mm is
installed in the supply cable.
Wiring diagrams
■ There is a label showing the wiring
diagrams on the underside of the appliance.
Supply terminals
■ The supply terminals are accessible by
removing the cover plate on the underside.
You can make the cross connections
needed using the jumpers on the terminal
block. Do not forget to secure the cable with
the cable clamp. Refit the cover plate after
you have secured the cable.
Electrical connection
Two or three phases.
Technical data
oven type 983 963 943
model
combi-oven
with cooker electric gas
electrical connection
230 V ■ ■
230 V -
380 V/400V ■
50 Hz ■ ■ ■
nominal
power kW 2,5 9,5 2,5
Combination of oven 943 with Pelgrim cooker
(see Figure 6)
For installation of this combination appliance,
see the cooker instructions.
Solo oven 983 (see Figure 7)
■ Connect oven to the electrical mains.
■ Slide the oven into the cupboard.
■ Open the oven door and fasten the oven
with two screws on each side wall.
Combination of the 963 oven and the Pelgrim
electrical or ceramic cooker
After the electrical or ceramic cooker has
been installed in accordance with the
instructions supplied with the appliance:
■ Connect the oven to the electrical mains
and connect the cooker’s 12-pole plug to
the oven’s counter-plug.
■ Now slide the oven into the cupboard.
■ Open the oven door and fasten the oven
with two screws on each side wall.