installation
The appliance can be connected in the following ways:
Common connections:
2 lives with 2 neutrals connection (2 2N a.c. 230 V / 50 Hz / Cooking
circuit): The voltage between live and neutral is 230 V a.c. There may be a
voltage of 0 V between the phases if they are connected to the same phase in
the meter cupboard but also 400 V if they are connected to 2 different phases.
Your groups must be fused with at least 16 A (2x). The connecting power cable
must have a minimum core cross section of 2,5 mm
2
.
3 lives with 1 neutral connection (3 1N a.c. 400 V / 50 Hz / Power circuit):
The voltage between the phases and the neutral is 230 V a.c. There is a voltage
of 400 V between the lives. Fit a connecting bridge between the connection
points 4-5. Phase 3 carries no load. Your groups must be fused with at least
16 A (3x). The connecting power cable must have a minimum core cross section
of 2,5 mm
2
.
installation
Electrical connection
For the connection, use an approved cable, in accordance with the regulations.
The cable must bear one of the following indications: H05V2V2-F, H05RR-F or
H05RN-F.
There is a label on the underside of the appliance with the wiring diagrams.
The connection terminals are accessible once you have opened the junction
box on the underneath. The junction box cover can be opened with a
screwdriver.
If you want to make a fixed connection, make sure that a multi-polar switch with
a contact separation of at least 3 mm is fitted in the supply line.
Power setting table
Type of hob induction
Component voltage 230 V/50 Hz
Appliance width x depth 774 x 522 mm
Installation height from top of worktop 48 mm
Cut out dimensions width x depth 750 x 490 mm
Capacity of modules
Left 3100 W
Warming zone 130 W
Right 2800 W