7. Before starting the equipment
Before you connect the equipment to the mains supp-
ly make sure that the data on the rating plate are iden-
tical to the mains data.
Check the equipment for damage which may have
occurred in transit. Report any damage immediately
to the transport company which was used to deliver
the compressor.
Install the compressor near the point of consumpti-
on.
Avoid long air lines and supply lines (extension ca-
bles).
Make sure that the intake air is dry and dustfree.
Do not install the compressor in a damp or wet
room.
The compressor may only be used in suitable rooms
(with good ventilation and an ambient temperature
from +5 °C to 40 °C). There must be no dust, acids,
vapors, explosive gases or inammable gases in the
room.
The compressor is designed to be used in dry
rooms. It is prohibited to use the compressor in are-
as where work is conducted with sprayed water.
The oil level in the compressor pump has to be che-
cked before putting the equipment into operation
(see 10.4).
8. Attachment and operation
n Important!
Remove the transportation braces (between the
compressor pump and cladding, see Fig. 7) prior
to initial start-up. If the transportation braces are
not removed, heat can build up and cause the
compressor to ignite.
n Important!
You must fully assemble the appliance before us-
ing it for the  rst time!
You will require the following tools for assembly and
installation: 2 x open-ended wrench size 13 mm (not
included)
8.1 Fitting the wheels (11)
Fit the supplied wheels as shown in Figure 5.
8.2 Fitting the supporting foot (8)
Fit the supplied supporting foot as shown in Figure 6.
8.3 Fitting the air lter (15)
Remove the transportation stop (B) and screw the
air  lter (15) to the equipment. (Fig. 7, 8).
8.4 Changing the transportation cover (A)
Remove the transportation cover from the oil lter
opening (21) and insert the supplied oil sealing plug
(16) into the oil  ller opening. (Fig. 9, 10.)
8.5 Mains connection
The compressor is equipped with a mains cable
with shock-proof plug. This can be connected to any
230V ~ 50 Hz shock-proof socket which is protected
by a 16 A fuse.
Before you use the machine, make sure that the
mains voltage is the same as the operating voltage
(see the rating plate).
Long supply cables, extensions, cable reels etc.
cause a drop in voltage and can impede motor start-
up.
At low temperatures below +5°C, sluggishness may
make starting difcult or impossible.
8.6 ON/OFF switch (Fig. 2)
Pull the ON/OFF switch (17) upwards to switch on
the compressor. To switch off the compressor, press
the ON/OFF switch down.
8.7 Setting the pressure (Fig. 1-3)
Use the pressure regulator (3) to set the pressure on
the pressure gauge (5).
The set pressure can be drawn from the quicklock
coupling (4).
The vessel pressure can be read off the pressure
gauge (6).
The vessel pressure is drawn from the quicklock
coupling (20).
8.8 Setting the pressure switch (Fig. 1)
The pressure switch (2) is set at the factory. Cut-in
pressure approx. 6 bar Cut-out pressure approx. 8
bar.
8.9 Fitting the compressed air hose (Fig. 1, 3)
Use the compressed air hose (14) if you intend to
carry out work at a greater distance from the com-
pressor. To do so, connect the nipple (H) on the
compressed air hose to one of the quickrelease cou-
plings (4, 20). Then attach the compressed air tool
to the quick-release coupling (G) on the compressed
air hose.
9. Electrical connection
The electrical motor installed is connected and
ready for operation. The connection complies with
the applicable VDE and DIN provisions.
The customer‘s mains connection as well as the
extension cable used must also comply with these
regulations.
Damaged electrical connection cable
The insulation on electrical connection cables is often
damaged.
This may have the following causes:
Passage points, where connection cables are
passed through windows or doors.
10

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Parkside PKO 270 A1 - IAN 96894 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Parkside PKO 270 A1 - IAN 96894 in de taal/talen: Nederlands, Duits, Engels, Frans als bijlage per email.

De handleiding is 4,43 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info