796533
1
Verklein
Vergroot
Pagina terug
1/2
Pagina verder

INTRODUCTION
Thank you for selecting this Oregon ScienticTM Wireless
Indoor / Outdoor Thermometer with Indoor Humidity and Self-
Setting Atomic clock (RMR383HGA). This clock is supplied
with a remote sensor (THN132N) and can support up to 3
sensors in total (additional sensors sold separately).
NOTE Please keep this manual handy as you use your new
product. It contains practical step-by-step instructions, as well
as technical specications and warnings you should know
about.
CLOCK OVERVIEW
FRONT VIEW
1. SNOOZE
2. Temperature and Humidity Area
3. Clock / Alarm Area
4. ALARM: View alarm status; set alarm
BACK VIEW
1. / : Increase / decrease setting; activate /
deactivate clock reception signal
2. MODE: Change settings / display
3. CHANNEL: Switch remote sensor display
4. MEM: View current, maximum and minimum
temperature / humidity
5. °C / °F: Select temperature unit
6. HEAT INDEX
7. TEMP / HUMIDITY HI / LO : Change settings
or enable / disable hi or lo temperature / humidity
alarm
8. RESET: Reset unit to default settings
9. ZONE: Toggle US time zone
10. Battery compartment
LCD DISPLAY
Temperature and Humidity area:




1. Heat Index icon
2. Hi / lo temperature alarm
3. Max / min temperature icon
4. Sensor reception icon
5. Comfort Zone
6. Battery low icon
7. Hi / lo humidity alarm
8. Max / min humidity icon
9. Ice warning is active
10. Temperature trend
11. Temperature
12. Heat Index warning
13. Humidity
14. Humidity trend
Clock / Alarm area:
1. Clock signal reception
2. AM / PM mode selected
3. Alarm mode
4. Alarm set
5. AM / PM mode selected
6. Alarm time
7. US time zone
8. Clock
9. Moon phase
REMOTE SENSOR (THN132N)
1. LED indicator 1. Wall mount
2. Battery compartment
3. Battery door
4. Table stand
5. RESET
6. CHANNEL switch
GETTING STARTED
BATTERIES
Insert batteries before rst use, matching the polarity (+ and
-). Press RESET after each battery change.
indicates main unit batteries are low.
NOTE Do not use rechargeable batteries. We recommend
that you use alkaline batteries with this product for longer
usage and lithium batteries in temperatures below freezing.
REMOTE SENSOR
The sensor collects temperature readings approx. every 40
seconds and sends them to the main unit. The main unit can
collect data from up to 3 sensors.
To set up the sensor:
1. Slide open the battery door.
2. Insert the batteries, matching the polarity (+ / -). Reset
the sensor after each battery change.
3. Select a channel. Make sure you use a different channel
for each sensor.
4. Close the battery compartment.
5. Secure the sensor in the desired location using the wall
mount or table stand.
For best results:
Place the sensor out of direct sunlight and moisture.
Do not place the sensor more than 30 m (100 ft) from the
main (indoor) unit.
Position the sensor so that it faces the main (indoor)
unit, minimizing obstructions such as doors, walls, and
furniture.
Place the sensor in a location with a clear view to the
sky, away from metallic or electronic objects.
Position the sensor close to the main unit during cold
winter months as below-freezing temperatures may affect
battery performance and signal transmission.
The transmission range may vary depending on many factors.
You may need to experiment with various locations to get
the best results.
Standard Alkaline batteries contain signicant amounts of
water. Because of this they will freeze in low temperatures
of approximately -12°C (10°F). Disposable Lithium batteries
have a much lower threshold for temperature with an
estimated freezing range of below -30°C (-22°F).
Wireless ranges can be impacted by a variety of factors
such as extremely cold temperatures. Extreme cold may
temporarily reduce the effective range between the sensor
and the base station. If the unit’s performance fails due to
low temperature, the unit will resume proper functioning as
the temperature rises to within the normal temperature range
(i.e. no permanent damage will occur to the unit due to low
temperatures).
SENSOR DATA TRANSMISSION
The sensor reception icon in the temperature and humidity
area shows the status.
ICON DESCRIPTION
Main unit is searching for the
sensor(s)
A channel has been found and
sensor signal is being received
and “- - . -“ The sensor cannot be found.
(Temperature Search for the sensor or
and Humidity Area) check batteries
To search for a sensor:
Simultaneously, press and hold MEM and CHANNEL for
2 seconds.
NOTE If the sensor is still not found, check the batteries,
obstructions, and remote unit location.
CLOCK
CLOCK RECEPTION
This product is designed to synchronize its date and time
automatically once it is within range of the WWVB-60
signal from the atomic clock in Fort Collins, Colorado.
The clock collects the radio signals whenever it is within 3219
km (2000 miles) of a signal.
NOTE Press ZONE to select the US time zone: Pacic (P),
Eastern (E), Central (C) or Mountain (M).
NOTE Initial reception takes 2-10 minutes for rst set up or
when RESET is pressed. Once complete, the reception icon
will stop blinking. If the signal is weak, it can take up to 24
hours to get a valid signal.
RECEPTION SIGNAL
Clock signal reception indicator:
STRONG SIGNAL WEAK SIGNAL NO SIGNAL
To enable and force a signal search:
Press and hold for 2 seconds.
To disable the signal reception:
Press and hold for 2 seconds.
SET CLOCK
If the clock signal reception is enabled and a signal is being
received the clock does not need to be manually set.
To manually set the clock:
1. Press and hold MODE for 2 seconds.
2. Press and to change the settings.
3. Press MODE to conrm.
4. The setting sequence is: 12/24 hour format, hour, minute,
year, date / month format, month, date, and display
language.
Wireless Indoor / Outdoor Thermometer
with Indoor Humidity and
Self-Setting Atomic Clock
Model: RMR383HGA
USER MANUAL
RMR383HGA_M_R6 2006.4.7, 10:19 AM1
1

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Oregon Scientific RMR383HGA bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Oregon Scientific RMR383HGA in de taal/talen: Engels als bijlage per email.

De handleiding is 1 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info