30
EN
17 / INDICATIONS FOR THE TESTING LABORATORIES
•
Details common to all models
— Washing capacity - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13 standard place settings.
— Arrangement of the items - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Figs. A-B-C ;
see next page.
— Loading as per the indications on next page.
— Setting for upper basket - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Low position.
— Setting for rinsing product distributor - - - - - - - - - - - - - - - - - - - 3
— Adjusting the water softener - - - - - - - - - - - - - - - - - - - - - - - - - - - 1.8 - 2.5 mmol/l
(See § 5 for details).
For detailed information on the comparison tests regarding the level of soiling, the types of
crockery and cutlery, etc., contact the equipment manufacturer before commencing the tests.
•
Tests to Standard EN 50242
— Recommended programme - - - - - - - - - - - - - - - - - - - - - - - - - - - see Programmes table.
— Dosage of detergent - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 32.5 g of detergent B.
•
Tests according to the mixed IEC 436/DIN 44990 method
— Recommended programme - - - - - - - - - - - - - - - - - - - - - - - - - - - see Programmes table.
— Dosage of detergent - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 5 + 27.5 g of detergent C.
NB:
When conducting tests using a multi-function tablet: Setting for hardness < 2.5 mmol/l
(See § 5 for details)
— Check that the water softener is correctly set for the water hardness
— Pull out the detergent distribution drawer and place the tablet in the interior compartment.
•
Built in or full built in model : Measuring the noise level in accordance with
Standard EN60704-2-3
— Align the plinth on the housing unit with the door panel.