ANY ENCLOSURE IN WHICH THE APPLIANCE IS USED MUST
COMPLY WITH ONE OF THE FOLLWING:
An enclosure with walls on all sides, but at least one permanent
opening at ground level and no overhead cover. Within a partial
enclosure that includes an overhead cover and no more than
two walls. Within a partial enclosure that includes an overhead
cover and more than two walls, the following shall apply-
at least 25% of the total wall area is completely open; and
at least 30 %of the remaining wall area is open and unrestrict-
ed.
In the case of balconies, at least 20%of the total of the side,
back and front wall areas shall be and remain open and unre-
stricted.
HOSE AND REGULATOR
These items are not included with the pizza oven. Only use
hose and regulators approved for LP gas at the above pres-
sures. The estimated life expectancy of the regulator is 10 years.
Change the regulator within 10 years of the date of manufac-
ture.
Using the wrong hose or regulator is unsafe; always check that
you have the correct items before operating the pizza oven.
The hose used must conform to the relevant standard for the
country of use. The length of the hose must be 1.2 meters
(maximum) and the inner diameter 10 mm. A worn or dam-
aged hose must be replaced. Ensure that the hose is not bent,
clogged, or in contact with any part of the pizza oven other
than at its connection.
LP GAS CYLINDER
The LP gas cylinder should not be dropped or handled roughly!
If the pizza oven is not in use, the cylinder must be disconnect-
ed from the appliance. Place the protective cap on the cylinder
after disconnecting the cylinder from the appliance.
The LP cylinder must be stored outdoors in an upright position
and out of the reach of children. The cylinder must never be
stored in an environment where temperatures can reach over
50°C. Do not store the cylinder near ames, ignition ames, or
other sources of ignition.
DO NOT SMOKE NEAR THE LP GAS CYLINDER.
This pizza oven is designed for use outdoors, away from any
ammable materials. It is important that there are no overhead
obstructions and that there is a minimum distance of 1 m
from the side or rear of the appliance. It is important that the
ventilation openings of the pizza oven are not obstructed. The
pizza oven must be used on a level, stable surface. The appli-
ance should be protected from direct airow and positioned or
protected against direct penetration by any trickling water (e.g.
rain).
No modications should be made to any part of this pizza oven,
and repairs and maintenance should only be carried out by a
registered gas service company.
CONNECTING THE LP GAS CYLINDER
Before connection, ensure that there is no debris or dirt caught
in the head of the LP gas cylinder, regulator, burner, and burner
ports. Spiders and insects can nest within and clog the burner
and its inlet. A clogged burner can lead to a re beneath the
pizza oven.
Clean burner holes with a heavy-duty pipe cleaner.
Fit the hose to the appliance using a spanner to tighten it
onto the connection thread. If the hose is replaced, it must be
secured to the pizza oven and regulator connections with hose
clips. Disconnect the regulator from the cylinder according to
the directions when the pizza oven is not in use.
The pizza oven must be operated in a well-ventilated area. Do
not obstruct the ow of combustion air to the burner when the
appliance is in use. ONLY USE THIS APPLIANCE OUTDOORS.
BEFORE USE, CHECK FOR LEAKS IN THE HOSE AND/OR CONNEC-
TION THREADS.
Never check for leaks with a naked ame; always use a soapy
water solution.
SETTING UP THE PIZZA OVEN
Before the rst time using the oven, inspect it thoroughly for
leaks as instructed. Light up the oven and keep the burner
at Max ( ) for about 20 minutes. This will remove the storage
grease from the oven. Let the oven cool down for about 15 min-
utes. Clean the pizza stone. The pizza oven is now ready for use.
CHECKING FOR LEAKS
Make 2–3 uid ounces (6–9 dl) of leak detecting solution by
mixing one part dishwashing liquid with 3 parts water.
Ensure that the control valve is “OFF”.
Connect the regulator to the LP gas cylinder and ON/OFF valve
to the burner. Ensure that the connections are secure, and then
turn the gas ON.
Brush the soapy solution onto the hose and all joints. If bubbles
appear, you have a leak, which must be repaired before use.
Retest after xing the fault.
Turn the gas OFF at the LP gas cylinder after testing.
If leakage is detected and cannot be repaired, consult your gas
dealer to x the leak.
Outdoor area example 1
Outdoor area example 5
Outdoor area example 4
Outdoor area example 3
Outdoor area example 2
both ends
open
open side at
least 25 % of
total wall area
30 % or more
in total of the
remaining wall
area is open and
unrestricted
open side at
least 25 % of
total wall area
30 % or more
in total of the
remaining wall
area is open and
unrestricted
EN
610626_pizzauuni_Vomero_16_ko_EN-FI-SV-ET-LV-LT-RU.indd 5610626_pizzauuni_Vomero_16_ko_EN-FI-SV-ET-LV-LT-RU.indd 5 16.12.2021 7.47.4716.12.2021 7.47.47
5

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Mustang Vomero 16 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Mustang Vomero 16 in de taal/talen: Engels, Zweeds, Fins als bijlage per email.

De handleiding is 1.62 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info