658509
11
Verklein
Vergroot
Pagina terug
1/60
Pagina verder
ENGLISH en
11
Every 1000 hours of operation
Have an inspection carried out in an authorised
service centre. This significantly increases the
service life of the compressor.
8.3 Storage of device
1. Switch off the device and pull mains plug.
2. Depressurise the pressure vessel and all
connected compressed air tools.
3. Drain the condensed water of the pressure
vessel at the condensate outlet (3).
4. Store the device in such a way that
unauthorised persons cannot start it.
5. (Basic 250-24 W, Basic 250-50 W) Do not
place the device on its side. Oil might leak!
Attention!
Do not store the tool outdoors or in damp
conditions without protection.
Danger of frost
Attention!
Frost (< 5 °C) destroys the pump and accessories
as both always contain water! If there is a danger
of frost disassemble pump and accessories and
store in frost-free conditions.
Danger!
Repair of tools must be carried out by qualified
electricians only!
If you have Metabo devices that require repairs,
please contact your Metabo service centre. See
www.metabo.com for addresses.
You can download a list of spare parts from
www.metabo.com.
Danger!
The condensed water from the pressure vessel
contains oil residue and /or contaminations
hazardous to the environment. Dispose of the
condensed water in an environmentally-friendly
manner using respective collection sites!
Danger!
(Basic 250-24 W, Basic 250-50 W) Dispose of the
old oil from the compressor in an environmentally-
friendly manner using respective collection sites.
Observe national regulations on environmentally
compatible disposal and on the recycling of
disused machines, packaging and accessories.
Only for EU countries: Never dispose of
devices in your household waste! In
accordance with European Guideline 2002/
96/EC on used electronic and electric equipment
and its implementation in national legal systems,
used devices must be collected separately and
returned for environmentally compatible
recycling.
Danger!
Prior to all servicing:
Switch machine off. Disconnect the mains plug.
Wait until the device has stopped. Ensure that
there is no more pressure on the device and all
used compressed air tools and accessories.
Leave the device and all used compressed air
tools and accessories to cool down.
Any works other than the ones described in this
chapter, must be carried out only by a qualified
electrician or the service branch in your country.
After to all servicing:
Put back into operation and check all safety
installations. Ensure that there are no tools or
similar at or in the device.
Compressor does not run:
No mains voltage.
Check cables, plug, outlet and mains fuse.
Mains voltage too low.
Use only extension cables with sufficient core
cross-section (see chapter 12. Technical
Data). For cold device: Avoid extension cable.
For cold device: Depressurise the pressure
vessel.
Compressor was switched off by pulling the
mains plug while it was running.
First, switch off the compressor using the ON/
OFF switch (9), then switch on again.
Motor overheated, e.g. due to insufficient
cooling (cooling ribs covered).
Switch off the compressor using the ON/OFF
switch (9) .
Remedy the cause for overheating. Leave to
cool for about ten minutes.
Only model with motor protection switch (10):
Check motor protection switch (10) , if
required, reset by pressing it. (see fig. E, page
3).
Switch on the compressor again using the ON/
OFF switch (9) .
Compressor runs without building up
sufficient pressure.
Condensate outlet leaking.
Ensure that the condensate outlet (3) is
closed.
Check the seal of the drainage plug, if
required, replace.
Check valve leaking.
Have check valve serviced in authorised
service centre.
Compressed air tool does not get enough
pressure.
Pressure controller not open enough.
Open pressure controller (7) further.
Hose connection between compressor and
compressed air tool leaking.
Check hose connection; if required replace
damaged parts.
Explanatory notes on the specifications on page 3.
Changes due to technological progress reserved.
A =suction capacity
F =filling capacity
L
eff
=Effective output volume at 80% max.
pressure
p=max. pressure
V =vessel size
a =number of air outlets
z=number of cylinders
n
0
=max. torque
P
1
=rated input power
U=connection voltage
I=rated power
F
min
=min. fuse protection
IP =protection class
G =maximum overall length and core cross-
section of extension cables
A =dimensions (lxwxh)
T
max
=max. storage / operating temperature *
T
min
=min. storage / operating temperature **
Oel =oil quantity and quality for oil change
(depends on model)
m=weight
* = The service life of some components e.g. seal
in check valve is significantly reduced, if the
compressor is operated at high temperatures
(max. storage / operating temperature and higher).
** = At temperature below the min. storage /
operating temperature, there is danger of frost for
the condensate in the pressure vessel.
The technical specifications quoted are subject to
tolerances (in compliance with the relevant valid
standards).
Emission values
These values make it possible to assess the
emissions from the device and to compare
different devices. The actual load may be higher or
lower depending on the operating conditions, the
condition of the device or the accessories. Please
allow for breaks and periods when the load is lower
for assessment purposes. Arrange protective
measures for the user e.g. organisational
measures based on the adjusted estimates.
Typical A-effective perceived sound levels
:
L
pA
=sound-pressure level
L
WA
=acoustic power level
L
WA(G)
=guaranteed acoustic power level as per
2000/14/EC
K
pA
, K
WA
=uncertainty
Wear ear protectors!
Information on the nameplate:
A Manufacturer
B Item, version, serial number
C Machine designation
D Connection voltage / frequency
E Rated input power
F Rated power / protection type
G Max. torque
H Max. pressure
I CE mark – This machine conforms to the EC
directives as per Declaration of Conformity
J Year of manufacture
K Suction capacity
L Filling capacity
M Compressor speed
N Number of cylinders
O Boiler size
P Disposal symbol (see chapter 10.)
9. Repairs
10. Environmental Protection
11. Troubleshooting
12. Technical Data
1~ 230 V 50 Hz
P 1,50 kW S 3
I = 6,0 A IP 20
01532XX0 9998812345
Basic 250-24 W OF
1
-1
2850 min
220 l/min
120 l/min
2850 min
1
24 l
-1
YYYY
8 bar / 116 psi
B
C
D
E
F
G
H
A
K
L
M
N
O
P
I
J
11

Hulp nodig? Stel uw vraag in het forum

Spelregels
1

Forum

Metabo-Basic-250-50-W-OF

Zoeken resetten

  • Mijn metabo basic 250-50 w slaat niet automatisch af.
    Deze komt nieuw uit de doos.
    Na aansluiten en aanzetten van de compressor komt hij wel op druk en gaat naar 8bar en als hij op druk is slaat hij niet af maar valt hij terug naar 6bar en gaat dan gelijk weer naar 8bar. Gesteld op 18-2-2021 om 19:19

    Reageer op deze vraag Misbruik melden

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Metabo Basic 250-50 W OF bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Metabo Basic 250-50 W OF in de taal/talen: Alle talen als bijlage per email.

De handleiding is 7,05 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info