743148
2
Verklein
Vergroot
Pagina terug
1/16
Pagina verder
Read the instruction manual carefully before using this device, es-
pecially the safety instructions, and keep the instruction manual for
future use. Should you give this device to another person, it is vital
that you also pass on these instructions for use.
GB Safety instructions
Use the device only according to its intended purpose as specied in the
instruction manual.
The warranty will be invalidated if the device is used for purposes other than
those for which it is intended.
Only use the infrared bulb with the infrared lamp for which it is intended.
Do not use the device if it is not working correctly, if it has been dropped or has
fallen into water or has been damaged.
Do not use the device if the cable or plug are damaged.
Keep the device and cable well away from hot surfaces. Do not place the device
near sources of heat.
Do not attempt to repair the device yourself in the event of a malfunction since
this will invalidate the warranty. Repairs should only be carried out by authorised
service centres.
The device is designed for private households only and not for commercial use.
Before using make sure that the connecting cable is not damaged. It must not
come into contact with the hot electric light bulb.
Before connecting the device to your power supply, please ensure that the sup-
ply voltage stated on the rating plate is compatible with your mains supply.
Place device on a rm, level surface during use so that it cannot tip over. Do not
attach device to walls or ceilings.
Do not leave the device unattended when it is switched on.
Keep ammable objects such as textiles, glasses and combs away from the
infrared lamp.
Keep the infrared lamp at least 80 cm away from ammable objects.
Do not use the device unless it is completely dry.
Do not use the device outdoors or in damp rooms.
The device must not be used in the immediate vicinity of bathtubs, showers or
washbasins lled with water, and must not be used with wet hands.
Protect the device from moisture.
Do not immerse the device in water or other uids.
Never carry, pull or rotate the unit by the mains cable and never pinch the cable
between other objects.
Do not cover the device when it is warm.
Protect the device from shocks and vibration.
Attention, scalding danger!
- The bulb becomes hot.
- Do not touch the infra-red bulb and do not remove with the power
cord plugged in.
- Always disconnect the device from the power supply and allow the lamp
to cool before touching it.
Always switch the device off after use, before cleaning and care and in the event
of malfunctions during operation by disconnecting the plug from the socket.
Allow the infrared lamp to cool before putting it away.
This appliance can be used by children aged from 8 years and above and per-
sons with reduced physical, sensory or mental capabilities or lack of experience
and knowledge if they have been given supervision or instruction concerning
use of the appliance in a safe way and understand the hazards involved.
Children shall not play with the appliance.
Cleaning and user maintenance shall not be made by children without supervi-
sion.
Pain-killers and relaxants reduce the sensitivity of the skin to pain and heat; the
same applies to the consumption of alcohol. Consult your doctor before using
the device.
Persons, whose sensitivity is disturbed or impaired may only apply the device
according to the instructions of a physician.
This device is unsuitable for persons who are insensitive to heat.
Do not treat any parts of the body that have swellings, burns, inammation, pee-
ling skin, wounds or other sensitive points.
Do not use the device on skin that feels painful or numb.
If the skin becomes irritated, discontinue the treatment and consult a physician.
Always seek the advice of a doctor in case of doubt and follow his instructions
for treatment.
The distance to the lamp must be at least 40 cm to avoid that the intensity of
radiation gets too high and the warmth is felt as painful.
Do not look directly into the infra-red light. Always close your eyes during radia-
tion in order to prevent retinal injuries. You can also cover your eyes with a swab.
Do not exceed the maximum radiation time of 15 minutes.
The treatment should be pleasant. Stop at once and consult your doctor if you
feel pain or if the treatment seems unpleasant.
Device and controls
1
Infra-red light bulb
2
Lamp base
3
Power cord with plug
4
Lamp housing (adjustable in 4 directions)
Scope of supply
Please check rst of all that the device is complete and is not damaged in any
way. In case of doubt, do not use the it and contact your dealer or your service
centre. The following parts are included:
• 1 MEDISANA infrared lamp IR 100
• 1 Instruction manual
If you notice any transport damage during unpacking, please contact your dealer
without delay.
Cosmetic treatment
The MEDISANA infrared lamp IR 100 is suitable for assisting facial and beauty
care, particularly in the case of bad skin. Remove all traces of make-up before
treatment. The effect of the infra-red radiation opens up the pores in the skin.
This results in better and more effective cleaning of the skin. Creams and other
cosmetic materials are absorbed more intensively and quickly by the skin.
Operation
Please follow the safety instructions.
Check the power cord
3
.
Place the device on its base
2
on a rm, level surface.
The infrared bulb
1
must be rmly screwed in.
The device has an adjustable lamp housing
4
. The 4 settings from 0 ° to 45 °
allow the device to be individually positioned in accordance with requirements.
To prevent burns, only touch the lamp by the base if you wish to change the
position.
Plug the device into the mains and it will start up immediately.
The effect of the radiation is greatest from a short distance. Please operate the
equipment at a distance at which the heat feels comfortable, but no less than 40
cm. Increase the distance if the heat feels uncomfortable.
The duration of use is oriented to your sensitivity, but do not use for more than
15 minutes.
Unplug the equipment from the mains when treatment is complete.
Cleaning and maintenance
Before cleaning and replacing the bulb of the infrared lamp, unplug the equip-
ment from the mains and allow the device to cool.
Clean the device after cooling,
4
and
2
, with a damp cloth and then rub dry.
Do not use aggressive cleaning and scouring materials.
Never immerse the device in water.
Please ensure that water does not penetrate the internals of the device. Do not
use the device again until it is completely dry.
Always replace the bulb of the infra-red lamp with the same bulb type.
Store the device in a dry, cool place.
Infra-red light bulb
1
It must not be used one with a higher power as indicated on the rating plate.
Replacements for the light bulb can be bought where the appliance has been
bought or ordered directly from the producer (indicate model!).
The following replacement for the light bulb has to be used:
Philips Infrared R 95E 100 W.
In case the glass of the light bulb is broken immediately disconnect the appliance.
Attention! Injuring danger due to splinters of glass. Let the appliance cool
down. Carefully remove the part of the light bulb which is screwed in the socket
with a pair of pincers (protect your eyes) or have the appliance repaired by a ser-
vice agent. The light bulb is not part of the guarantee, it won’t be replaced free of
charge.
Disposal
This product must not be disposed of together with domestic waste.
All users are obliged to hand in all electrical or electronic devices,
regardless of whether or not they contain toxic substances, at a
municipal or commercial collection point so that they can be disposed
of in an environmentally acceptable manner. Consult your municipal authority or
your dealer for information about disposal.
Technical specications
Name and model :
Current supply :
Consumption :
Dimensions LxWxH :
Weight :
Storage conditions :
Item number :
EAN number :
Spare bulb :
WARNING
Please ensure that polythene packing is kept away from the reach
of children! Risk of suffocation!
WARNING
Do not exceed a radiation time of 15 minutes and 2 sessions a day.
The infra-red radiation emitted by the device is not suitable for
tanning.
The current version of this instruction manual can be found under www.medisana.com
In accordance with our policy of continual product improvement, we re-
serve the right to make technical and visual changes without notice.
Warranty and repair terms
Please contact your dealer or the service centre in case of a claim under the war-
ranty. If you have to return the unit, please enclose a copy of your receipt and
state what the defect is.
The following warranty terms apply:
1. The warranty period for MEDISANA products is three years from date of
purchase. In case of a warranty claim, the date of purchase has to be
proven by means of the sales receipt or invoice.
2. Defects in material or workmanship will be removed free of charge within
the warranty period.
3. Repairs under warranty do not extend the warranty period either for the
unit or for the replacement parts.
4. The following is excluded under the warranty:
a. All damage which has arisen due to improper treatment, e.g.
non-observance of the user instructions.
b. All damage which is due to repairs or tampering by the customer or
unauthorised third parties.
c. Damage which has arisen during transport from the manufacturer to
the consumer or during transport to the service centre.
d. Accessories which are subject to normal wear and tear.
5. Liability for direct or indirect consequential losses caused by the unit are
excluded even if the damage to the unit is accepted as a warranty claim.
MEDISANA GmbH
Jagenbergstraße 19, 41468 NEUSS
GERMANY
For service, accessories and spare parts, please contact:
UK - United Kingdom
+44 20 38680977
service.gb@medisana.com
MEDISANA Infrared lamp IR 100
220 - 240 V~ 50 - 60 Hz
100 watts
approx. 16.5 x 13.5 x 20.5 cm
approx. 0.36 kg
clean and dry
88232
40 15588 88232 6
Item number 30101
DE/GB
DE
GB
Gebrauchsanweisung
Instruction manual
INFRAROTLEUCHTE IR 100
INFRARED LAMP IR 100
Zeichenerklärung
Explanation of symbols
WICHTIG IMPORTANT
Die Nichtbeachtung dieser Anweisung
kann zu schweren Verletzungen oder
Schäden am Gerät führen.
Non-observance of these instructions can
result in serious injury or damage to the
device.
WARNUNG WARNING
Diese Warnhinweise müssen eingehalten
werden, um mögliche Verletzungen des
Benutzers zu verhindern.
These warning notes must be observed
to prevent any injury to the user.
ACHTUNG CAUTION
Diese Hinweise müssen eingehalten wer-
den, um mögliche Beschädigungen am
Gerät zu verhindern.
These notes must be observed to prevent
any damage to the device.
HINWEIS NOTE
Diese Hinweise geben Ihnen nützliche
Zusatzinformationen zur Installation oder
zum Betrieb. These notes give you useful
additional information on the installation
or operation.
Halten Sie mit der Infrarotleuchte einen
Mindestabstand von 80 cm zu brennbaren
Gegenständen.
Keep the infrared lamp at least 80 cm
away from ammable object
Heiße Oberäche! Hot surface!
Schutzklasse II
Protection category II
LOT-Nummer LOT number
Hersteller Manufacturer
Gerät und Bedienelemente
Device and controls
3
1
2
4
2

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Medisana IR 100 - 88232 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Medisana IR 100 - 88232 in de taal/talen: Alle talen als bijlage per email.

De handleiding is 1,14 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info