MM/MC cartridge select
There are two types--MM (Moving Magnet) and MC (Moving
Coil)--of cartridges for turntable.
As the output levels for these two types of cartridges differ,
the setting of the phono equalizer that is mounted in this unit
must be switched according to the type of cartridge for your
turntable. For switching, use the PHONO MC button on this unit.
Speaker impedance
This is certain-rated resistance of the speaker set to an
alternating current and expressed in ohms.
The smaller the impedance, the greater the output. However,
load on the amplifier is increased. Use speakers whose
impedance is supported by this unit
Bi-wiring Connection
This method of connecting a speaker by using two speaker
cables enables separate transmission of treble and bass
signals.
This enables playback with minimal interference between the
high-range speaker unit and the low-range speaker unit.
Protection Circuit
This is a function to prevent damage to components within
the power supply when an abnormality such as an overload or
excess voltage occurs for any reason.
In this unit, the power indicator blinks and the unit enters
standby mode when an abnormality occurs.
Troubleshooting
Troubleshooting
n About the protection circuit
This unit is equipped with a protection circuit to protect the
amplifier circuits and speaker system from damage.
If the protection circuit is activated, the sound is instantly
muted.
In this case, the message “PROTECT” flashes on the display
panel, and the STANDBY indicator also flashes.
To deactivate the protection circuit, turn the unit off then back
on again after about 1 minute or more.
At power on
For about 8 seconds after the power is turned on, the protection
circuit is activated, muting the sound to give the amplifier
circuits time to stabilize. Once the amplifier circuits stabilize,
the protection circuit is released, and audio is enabled.
In the event of overcurrent
The protection circuit is activated if current exceeding a certain
level is detected, which can happen if excessive signal flow is
input to the amplifier or if the unit is connected to a speaker
system of less than 4 Ω impedance. The protection circuit is
also activated if a speaker cable shorts.
In such cases, the message “PROTECT” flashes on the display,
and the volume is automatically reduced. After approximately
8 seconds, the protection circuit is released. Therefore, the
volume needs readjusting to continue normal use.
If the overcurrent continues, the amplifier shuts itself OFF,
and the STANDBY indicator flashes.
To deactivate the protection circuit, turn the unit off then back
on again after about 1 minute or more.
If excessive ultrabass signals are input
The protection circuit is also activated if ultrabass signals are
input. In such a case, the STANDBY indicator flashes, and
the volume is automatically reduced. After approximately
8 seconds, the protection circuit is released. Therefore, the
volume needs readjusting to continue normal use. If excessive
ultrabass signal input continues or if DC voltage is detected
owing to trouble with the amplifier, the amplifier shuts itself
OFF, and the STANDBY indicator flashes.
To deactivate the protection circuit, turn the unit off then back
on again after about 1 minute or more.
If the main-amplifier overheats
The protection circuit is activated if the temperature of the main
amplifier section rises above a certain level, which can happen
if the amplifier is continuously used with excessive signal flow
being input to it. The protection circuit is also activated when
the specified operating temperature is exceeded, which can
happen if the vents on top of the amplifier are covered or if
the amplifier is installed on a cramped audio rack. In such
a case, the STANDBY indicator flashes, and the volume is
automatically reduced. After approximately 8 seconds, the
protection circuit is released. Therefore, the volume needs
readjusting to continue normal use.
If the temperature does not sufficiently fall within a certain
amount of time after the protection circuit activation, the
amplifier shuts itself OFF, and the STANDBY indicator flashes.
To deactivate the protection circuit, turn the unit off, let it
stand until it cools down, then turn it ON again.
In the event of amplifier trouble
The protection circuit is activated, and the power is
automatically shut OFF, if an abnormality is detected in the
power circuit. The same happens if the main fuse inside the
amplifier blows. In such cases, the STANDBY indicator flashes.
Turn the unit off then after several minutes turn it on again.
If the display does not light up, and the STANDBY indicator
remains flashing after the unit is turned on again, the unit may
be in failure.
Explanation terms
1.PM-11S3U_ENG_0521.indd 21 2012/05/21 19:03:36
25

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Marantz PM-11S3 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Marantz PM-11S3 in de taal/talen: Engels als bijlage per email.

De handleiding is 7,63 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Andere handleiding(en) van Marantz PM-11S3

Marantz PM-11S3 Gebruiksaanwijzing - Nederlands - 34 pagina's

Marantz PM-11S3 Gebruiksaanwijzing - Deutsch - 34 pagina's


Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info