9. Extended operator functions
A7 Signal light
B7 Gate position OPEN
C7 Gate CLOSED position
D7 Intermediate position OPEN
E7 Intermediate position CLOSED
F7 Motor starts (wiping impulse – 1 second)
G7 Fault
H7 Lighting
Menu 7: Relay output
Legend:
LED off
LED on
LED flashes slowly
LED pulses
LED flashes quickly
Factory default setting
Not possible –
Operating Instructions, Comfort 580 GB (#91636) 39
Caution!
To exclude any risk of injury, the automatic cut-out (Menus 3 and 4) may only be switched to OFF if a
photocell barrier or closing edge safety device is installed.
* The higher the setting, the higher the driving power.
** The lower the setting, the more sensitive the automatic cut-out.
Level 2 – Operator settings
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Menu 1: Required driving power OPEN (sensitivity in increments*) (MASTER + SLAVE)
OFF 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Menu 2: Required driving power CLOSE (sensitivity in increments*) (MASTER + SLAVE)
OFF 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Menu 3: Automatic cut-out OPEN (sensitivity in increments**) (MASTER + SLAVE)
OFF 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Menu 4: Automatic cut-out CLOSE (sensitivity in increments**) (MASTER + SLAVE)
OFF 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16