Reference:
- If changes are made in Menus 3 and 4 in Level 1, a new performance check must be carried out
(Section 8.6.)
- The function of the signal light (A7) can be adjusted in level 3, menu 7.
- The function of the lighting (H7) can be adjusted in level 5, menu 4.
Advice:
- In case of single wing systems only the intermediate position that was programmed last can be used.
In case of double wing systems no intermediate position can be set.
- If the automatic closing function (Level 3 / Menu 1) is activated, the relay output (Level 1 / Menu 7)
can be reprogrammed if required.
9. Extended operator functions
9.4 Functions overview for the levels
Attention!
After a reset, all the parameters revert to the factory settings.
In order to guarantee the proper operation of the MASTER and SLAVE controls:
- all the required functions must be re-programmed,
- the remote control unit must be re-programmed,
- the MASTER and SLAVE motor units must be driven to the OPEN and CLOSED positions once.
Level 1 – Basic functions
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Menu 3: Intermediate position OPEN (only in case of single wing systems)
Set using the (+ / OPEN) and (- / CLOSE) buttons
“Intermediate position OPEN” – closing function is possible with automatic closing timer
Menu 4: Intermediate position CLOSE (only in case of single wing systems)
Set using the (+ / OPEN) and (- / CLOSE) buttons
Menu 7: Relay output – terminal 16/17 (MASTER only)
A7 B7 C7 D7 E7 F7 G7 H7 – – – – – – – –
Menu 8: RESET (MASTER + SLAVE)
No Yes – – – – – – – – – – – – – –
Reset
• Reset the SLAVE controls first and complete the controls test.
• Then reset the MASTER controls.
For a different sequence, the control unit must be disconnected from the mains and then switched on again.
38 Operating Instructions, Comfort 580 GB (#91636)