INSTALLER’S MANUAL
Appliances must be installed in a workmanlike manner in accordance with the instructions in
this manual and locally applicable regulations. This manual will be handed over to the user after
installation.
Before connection, check :
ü That the electrical supply of the system is compatible with the
voltage and power of the range.
ü That the user’s xed installation includes an approved all-pole
cut-out device.
Connection : ATTENTION :
- Cable insulation must be type 245 IEC 57 or 245 IEC 66
- The wires in the power supply cable between the anti-tugging device
and the terminals must be long enough to enable the live wires
to extend before the ground wire in the event of the cable being
pulled.
- If this unit is permanently connected to a xed electrical cable, the
cable should be equipped with a fault leak protector.
- If this unit is connected to a wall outlet, the outlet should be
permanently
Connection
- Remove rear cover:
→ Q : Unit with electric ovens, figure【1】 .
→ R : Gas/electric unit, figure【2】.
→ S : Unit with electric ovens and gas hob, figure【3】.
- Use a standard flexible cable to connect to terminal block T (fig.【
3】&【4】).
- Secure the cable by means of cable clamp U (fig.【3】).
It is hazardous to put the appliance into service without
connecting it to suitable ground.
【3】
【4】
T
U
Four mixte (gaz et électrique)
【2】
Fours électriques
【1】
R
Q
ELECTRIC CONNECTION
L
No liability can be accepted for accidents resulting from non-compliance with this
requirement or incorrect grounding.
【3】
Fours électriques et dessus
gaz
S