13
Operation
Use the fastest speed setting for particularly concentrated steam and
fumes. It is advisable to switch the hood on 5 minutes before starting
to cook and leave it running for another 15 minutes at the end of
cooking.
The control panel is composed of a backlit rotary disk
• To switch the lights on and off:
Press the disk (T) to turn the lights on and off
• To select the extraction speed available:
Turn the disk (T) clockwise to turn on and increase the extraction speed and counterclockwise to decrease
it, and turn off the hood.
The crown (L) lights on to indicate the extraction speed selected:
• L1 on
speed 1 (minimum). • L1+L2 on
speed 2 (medium).
• L1+L2+L3 on
speed 3 (maximum).
• L1+L2+ L3+L4 on in flashing mode
speed 4 (intensive): 5 minutes on, after which the hood automatically sets to speed 2
• L off:
Extraction motor off
Filters saturation control device
The hood is equipped with a device that signals when the filters require maintenance. The grease filter
saturation control device is always on. The activated carbon filter control device is usually off.
To turn it on, proceed as follows:
- Turn off the hood.
- Press the disk (T), for more than 5 seconds
The crown (L) lights up completely, flashing, and an acoustic signal is emitted: the activated carbon filter
control device is on.
Note = to turn it off, turn off the hood and press the disk
(T), L1+L2 are backlit and flashing; wait for the acoustic signal that confirms that they are off.
Grease filter saturation indicator
L1 + L2 will flash when maintenance is required on the grease filter
Activated carbon filter saturation indicator
L3 + L4 will flash when maintenance is required on the activated carbon filter
Filter saturation signaling reset
After the filters maintenance turn on the hood and press the disk (T) for more than 5 seconds: a long
acoustic signal (beep) is emitted to indicate that the reset was completed successfully.
Note: in case of simultaneous signaling (grease filter and activated carbon filter saturation), it is necessary
to repeat the reset operation twice.