771567
19
Verklein
Vergroot
Pagina terug
1/32
Pagina verder
pag. 19
5.2 System address and network address setting
1) After first powered on, please set the system address by remote controller or wired
controller, the address range is 0-63, the indoor unit addresses of the same system
can not be repeated.
2) Display as the table.5-2, when there are different ENC1, the address setting will be dif-
ferent;
Each independent control box needs to be set an address, this address is an actual
address; when the capacity code ENC1 is selected to be E-4, this indoor unit inde-
pendent control box will produce virtual address(es) with corresponding quantity based
on the set actual address, and if an address has been an actual address or virtual
address, then this address can not be the actual address or virtual address of other
indoor unit in the same system;
For example, if there are two independent control boxes in the same system, one of
the capacity code is E, the setting actual address is 5, then according to the table.7-2
this control box will produce one virtual address as 6, and then the actual address and
the virtual address of the other independent control box can not be any one of 5, 6;
The actual address and the virtual address should less than or equal to 63.
3) The indoor unit quantity detected by outdoor unit will be the sum of the actual address
quantity and the virtual address quantity, e.g. when the capacity code of independent
control box is E, the setting actual address is 5, then it will produce virtual address 6,
and then the indoor unit quantity detected by outdoor unit will be 2.
4) The outdoor unit can not use auto addressing for to set the address for the indoor unit
without address; only the indoor unit has address then can the outdoor unit to be set
auto addressing;
5) When the independent control box system connects to the indoor unit centralized con-
troller, the actual address and the virtualaddress will be displayed on the centralized
controller, e.g. when the capacity code of independent control box is E, the setting
actual address is 5, then the actual address 5 and virtual address 6, will be displayed
on the centralized controller, that is to say, it equals to two indoor units, and the states
of four indoor units will be kept in the same;
6)The network address is the same as the indoor unit address, no need to setting sepa-
rately.
5.1 Application control
Refer to the specific manuals "AHU AHU Control box" and "Wired Controller" sup-
plied with the unit; below are explained the main instructions.
Set the PCB code of the indoor unit electric control box by different usage.
After setting, be sure to turn off the total power switch and then switch on.
The setting function can not be carried out if not to turn off the total power switch and then
switch on (SW4-2, ENC1).
5.3 - Checks before start up
Before starting the unit check the following:
Anchorage of the unit to the ceiling.
Connection of the air ducts.
Connection of the earth cable.
Fixing of all the electric terminals
SW4-2 ENC1 Corresponding Virtual Addresses Qty of Occupied
Addresses
00~D No virtual address 1
0 E-F Actual address +1 / / / / 2
00-1 Actual address +1 / / / / 2
02-4 Actual address +1 Actual address +2 Actual address +3 / / 4
Table. 5-2
Table 5-1 Capacities of SW4-2 and ENC1
SECTION 5 - SETTINGS MODULE



')#&*
$(
')#&*

$(
KAHU-90.4
$(
$(
$(
$(
$(
$(
$(
KAHU-200.4
$(
$(
$(
$(
$(
$(
$(
KAHU-360.4
$(
$(
$(
$(
KAHU-560.4
$(
$(
Capacity Capacity
- Function specification:
SW4-2, ENC1 - Cooling capacity setting, set the
cooling capacity of this machine (Table. 5-1).
DipSW factory settings:
SW1: 0000 (leaving the differential for thermo-off
in cooling by default at 0 ° C)
SW2: 0000
SW3: 0001 (compensation in heating 2 ° C, the
only dipSW to actually move)
SW4: 0000
SW9: 000
SW10: 00 (identifies UTA kit size)
Capacity settings:
- KRE-500DX1
(3 kW in cooling) -> 1HP -> SW4-2=0, ENC1=1
- KRE-1000DX1
(5,8 kW in cooling) -> 2HP -> SW4-2=0, ENC1=4
19

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Kaysun KRE-500DX1 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Kaysun KRE-500DX1 in de taal/talen: Engels als bijlage per email.

De handleiding is 2.81 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info