819268
2
Verklein
Vergroot
Pagina terug
1/2
Pagina verder
Oral (ages 2+ only)
Note: DO NOT eat or drink anything before the measurement, or bite on the product.
To ensure that reading is as accurate as possible, place the thermometric sensor to the left or right
of the underneath/root of the tongue. Ensure the screen faces upwards.
The thermometric sensor must have constant contact with the tissue during the reading and be
placed under the tongue in one of the two heat pockets at the back. Press the tongue down to
hold the product in place.
Keep the mouth closed during the
reading and breathe evenly through
the nose, while holding onto the
product to keep it from moving during
measurement.
There are different heat zones in the
mouth. Generally, the oral temperature
is 0.3°C to 0.8°C lower than the rectal
temperature.
Rectal
Note: This is the most accurate method from a medical point of view, because it comes closest to
the core body temperature. It is commonly used for young children when it is difcult to take an oral
or underarm temperature. DO NOT attempt rectal measurements on persons with rectal disorders.
Lubricate with a water-soluble gel. DO NOT use petroleum jelly.
Gently insert the thermometric sensor no more than 2cm into the rectum. DO NOT force the
product into the rectum. Stop insertion and abort the measurement when pain is present.
Note: The rectal method is the most accurate method for identifying the basal temperature
and it is advised to extend the measuring time by 3 minutes after the beep.
Underarm (axillary)
Note: Wipe off any underarm perspiration and deodorant prior to taking a reading under the arm.
Place the thermometric
sensor in the centre of the
armpit. It must be touching
the skin, remove clothing if
necessary.
Turn the screen so that it
faces inwards.
Hold the product in place by
slightly applying pressure
inwards towards the body.
The product should be placed at an angle of 35-45 degrees in relation to the arm.
When using with infants or young children, it is advised to gently hold their arm in place
while taking the measurement.
Placing the product in the armpit provides a measurement of surface temperature that can
uctuate by around 0.5°C to 1.5°C from rectal temperature readings in adults.
Note: An exact reading cannot be obtained if, the armpits have been allowed to cool. If this is
the case, we recommend extending the measuring time by around 5 minutes in order to obtain
the most precise possible reading that corresponds as closely as possible to the core body
temperature.
Maintenance
Cleaning
Always clean/disinfect the product before and after use to avoid cross contamination.
Only clean with disinfectant (70% medical alcohol) using a damp cloth.
Rinse only the thermometric tip under slow running cold water and then dry with a
clean soft cloth.
DO NOT use harsh chemical cleaning agents.
DO NOT immerse the product under water; rinse with hot water over 50°C; soak in alcohol
for a long period of time; or use ultrasonic washing to clean the product as this can damage
the electronics.
Storage
Wipe away any dirt and dust from the product.
Store the product in it’s protective cover while not in use.
DO NOT store the product in the protective cover when it is damp. Wipe it off with
a clean dry soft cloth rst.
Store in a safe cool dry place, away from children as per Safety Warnings.
DO NOT place any heavy objects on the product.
Battery Replacement
When the low battery symbol is shown on the bottom right of the screen, please
replace the battery.
Using a small Phillips Head screwdriver size #00 or #000 to remove the safety screw from
the back of the battery compartment cover.
Remove the battery compartment cover and
gently pull out plastic circuit board with battery
chamber approximately 1 cm.
Use pointed object such as a pen to remove
the old battery.
Dispose of the old battery according to current
local regulations.
Only use batteries specied for the product.
Install the battery carefully with the polarity in the correct position with the positive(+)
polarity facing towards the back of the thermometer.
Slide battery chamber back into place.
Replace the battery compartment cover and ensure the safety screw is tightly secured.
Troubleshooting
A full troubleshooting guide can be found at www.jadavey.com.au
If the problem is not solved by the troubleshooting guide or you have any queries, please
contact our service centre:
In Australia - 1800 807 464 In New Zealand - 0800 523 583
DO NOT attempt to open or repair the product yourself.
Note: The product is initially calibrated at the time of manufacture. If this product is used
according to the instructions, re-calibration should not be required. However, if you feel that
the product is out of specication, please contact us.
Technical Data
Power Type/Rating Zinc Manganese Alkaline Button Battery (LR41 1.5V DC)
Battery Life Approx. 200 hours
Thermometer Type Maximum (Oral, Rectal & Underarm). Sensing unit = Thermistor.
Measurement Range 32.0 - 42.9°C / 89.6 - 109.2°F
Measurement Scale
Increments
0.1°C / 0.1°F
Measurement
Accuracy
±0.1°C (±0.2°F) during 35.5°C~42.0°C (95.9°F~107.6°F) at
18°C~28°C (64.4°F~82.4°F ) ambient operating range
±0.2°C (±0.4°F) for other measuring and ambient operating range
Operating Conditions Temperature: 5 - 40°C
Humidity: 15°C - 95°C RH (non-condensing)
Atmospheric pressure: 700hPa to 1060hPa
Storage/Transport
Conditions Temperature: -20 - 55°C
Humidity: 15°C - 95°C RH (non-condensing)
Atmospheric pressure: 700hPa to 1060hPa
Dimensions 13.8cm x 2.2cm x 1.2cm (L x W x H)
Weight Approx. 12g including battery
IP Rating IP27
The rst digit indicates the level of protection that the enclosure
provides against access to any hazardous parts and the ingress of
solid foreign particles.
2 = protection against particles >12.5mm
The second digit indicates the level of protection that the enclosure
provides against the harmful ingress of water.
7 = Protected from immersion between 15 cm and 1 m in depth.
Applied Part
Type BF Equipment
– Degree of protection against electric shock
Materials ABS + TPE plastic, Stainless Steel, Silica Gel, LCD Screen, Nickel
Plated Iron Safety Screw
Contents Welcare Digital Thermometer, Storage Case, Battery (installed in
product), Instruction Manual
Your Welcare Digital Thermometer comes with a 1 Year Limited Warranty.
See the enclosed Warranty Card for further information.
Register your warranty online at www.jadavey.com.au
For warranty repairs call:
In Australia - 1800 807 464 In New Zealand - 0800 523 583
This device complies with the provisions of the EC directive 93/42/EEC (Medical Device
Directive) and the European Standard EN124703:2000+A1:2009, Clinical thermometers
- Part 3: Performance of compact electrical thermometers (nonpredictive and predictive)
with maximum device.
Important information regarding Electro Magnetic Compatibility (EMC)
Welcare Digital Thermometer manufactured by Joytech Healthcare Co., Ltd conforms to
EN60601- 1-2:2015 Electro Magnetic Compatibility (EMC) standard.
Further documentation in accordance with this EMC standard is available at
http://www.estore.jadavey.com.au
Disposal
At the end of its life, please treat this product and batteries as electronic waste and
dispose of responsibly according to current local regulations.
v10/20
Manufactured by:
JOYTECH HEALTHCARE CO., LTD
No.365, Wuzhou Road, Yuhang Economic Development
Zone, 311100, Hangzhou, China.
Distributed by:
(Australia)
JA DAVEY PTY LTD
626 Lorimer Street
Port Melbourne, VIC 3207
(New Zealand)
JA DAVEY LTD
C/- Healthcare Logistics
58 Richard Pearse Drive
Mangere, Auckland 2022
Remove safety screw
Remove battery
compartment cover
Battery
compartment
cover
Place tip in
centre of
armpit.
Raise arm
35˚– 45˚
Lower arm
to hold
product in
place
Face screen
inwards
Placement points under
the root of the tongue
Tongue
Root of tongue
Face screen
upwards
2

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Joytech WDT404 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Joytech WDT404 in de taal/talen: Engels als bijlage per email.

De handleiding is 0.35 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info