The JA-80Y GSM communicator - 5 - MFJ55304
5.1. Language setting
Language of the text used by the communicator can be set by
instruction:
981 xx
Where:
01 EN English 10 FI Finnish
02 CZ Czech 11 NO Norwegian
03 SK Slovak 12 SV Swedish
04 NL Dutch 13 FR French
05 DE German 14 HU Hungarian
06 PL Polish 15 RU Russian
07 DA Danish 16 TR Turkish
08 IT Italian 17 SP Spanish
09 PT Portuguese
Note:
Set the language before editing the text in the system (change of
the language will change the text to the factory default)
Change of the language in the communicator will automatically
result in changing the language in the connected keypad (also the
wireless keypad if connected)
Set language will not be change when reset is performed
Example: by setting 98102 the Czech language will be set.
Factory default : 98101 = English
5.2. GSM signal strength measurement
Good quality GSM signals are necessary for the reliable functioning of
the communicator. Entering 922 starts GSM signal measurement. The
keypad then displays the signal strength in the range 1/4 to 4/4 and
measurement is repeated every second (indicated by beeps). This mode
allows a suitable location to be found for the control panel (or the GSM
antenna). Press the # key to exit GSM signal measurement.
The SMS reply to a STATUS interrogation now displays GSM signal
strength in the range 0/9 to 9/9.
The signal should read at least 2/4. In places with a weak signal we
recommended trying another GSM provider’s SIM card.
Warning: it is not recommended to use a high-gain or directional GSM
antenna to get a better signal, as this way the communicator would only
communicate with a single cellular base station and communication
would not be stable. Also be aware that the GSM system cannot work
properly if the distance from the cellular base station is longer than 30km
(even if the signal is strong enough) as the time delays in the data
exchange would be longer than acceptable to the GSM standard.
5.3. Programming tel. numbers for reporting to phones
See part 4.
5.4. Selection of the events reported to phones
The factory-default list of reported events and their assignment to
telephone numbers M1 to M8 can be altered by this sequence.
The complete list of reportable events is shown in the following table.
It is possible to select whether the event should be reported by an
SMS or by a phone call, or by both an SMS followed by a phone call
Each event has pre-programmed factory-default SMS text. These
texts can be edited (see 5.5). The acoustic signals for phone call
reporting are fixed and cannot be changed (e.g. an alarm is
indicated by a siren sound if a reporting call is answered)
List of events which can be reported to phones and their factory-default assignment to particular phone numbers
Phone number memory M
ec Event
1 2 3 4 5 6 7 8
01 Intruder alarm - instant S S SC SC SC SC C
02 Intruder alarm - delayed S S SC SC SC SC C
03 Fire alarm S S SC SC SC SC C
04 Panic alarm S S SC SC SC SC C
05 Number of permitted incorrect code-entries
exceeded
S S SC SC SC SC C
06 Alarm triggered during control panel
power-up
S S SC SC SC SC C
07 Tamper alarm S S S S S S
08 End of tamper alarm
09 End of alarm indication
10 Alarm cancelled by user S S S S S S
11 Setting S S
12 Unsetting S S
13 Partial setting S S
14 Codeless setting S S
15 External communication fault S S S S S S S
16 External communication restored
17 Fault S S S S S S S
18 Fault no longer present
19 Mains dropout longer than 30 minutes S S S S S S S
20 Mains dropout
21 Mains restored
22 Discharged battery S S S S S S S
23 Battery OK
24 Switching to Service Mode
25 Leaving Service Mode
26 PGX ON/OFF
27 PGY ON/OFF
28 Radio communication jamming present S S S S S S S
29 Internal communication fault S S S S S S S
30 Internal communication restored
31 Communication test
32 Unconfirmed alarm
Factory-default report assignment: S = SMS, C = call, SC = SMS followed by a call
External communication fault means a GSM network dropout longer than 15 minutes (if GSM network dropout indication is enabled)
The SMS information about a new picture on the server is sent to all phone numbers which are set to get reported event number 01 “Intruder
alarm - instant”. This information contains a link to the new picture on the server.
5

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw Jablotron JA-80Y - GSM communicator bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van Jablotron JA-80Y - GSM communicator in de taal/talen: Engels als bijlage per email.

De handleiding is 0,17 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Andere handleiding(en) van Jablotron JA-80Y - GSM communicator

Jablotron JA-80Y - GSM communicator Gebruiksaanwijzing - English - 16 pagina's


Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info