4. POWER SUPPLY
REMAINING BATTERY POWER DISPLAY
After the remaining battery power warnings appear, the
GY-DV5000 automatically stops operation if the battery
power operation is continued.
Operating Time with Battery Pack
When the VF-P115B is used as the viewfinder and a fully
charged battery pack is attached, the approximate continuous
operating time is as follows:
Battery operating time may differ depending on the age of
the battery, charging conditions and the operating
environment, etc. Use the values in the table on the left for
approximate reference times.
Operating time is reduced in areas with a cold environment.
Operating time is reduced when the power zoom lens and
LCD are used frequently.
Battery Pack Continuous Operating Time (at 25 ˚C)
NP-1B 60 minutes
Magnum 14 130 minutes
NP-L40 80 minutes
PRECAUTIONS FOR THE BATTERY PACK
When the battery pack is not in use, it must be stored in a
cool, dry place.
Do not leave the battery pack in a place where it might be
subject to a high temperature (under direct sunlight in a car,
etc.), this could cause leakage of the fluid or shorten service
life.
When the terminal section of the battery pack gets dirty, the
operating time will be shortened.
If the operating time becomes greatly reduced even
immediately after recharging, the service life of the battery
pack is nearly finished. Purchase a new battery pack.
Recharging
Recharge the battery pack after completely discharging it.
Repeated recharging with residual charge remaining could
result in reduced battery capacity.
If the battery capacity is reduced by repeating incomplete
recharging, or recharging without discharging, once discharge
the battery pack completely, then recharge it to restore the
battery capacity.
If the battery pack is recharged with its internal temperature
raised immediately after use, recharging may not be
performed completely.
To display the remaining battery power accurately, set the
BATTERY TYPE item on the OTHERS (2/2) menu screen
in accordance with the type of the battery pack in use.
See “BATTERY TYPE” on page 78.
When the remaining battery power is nearly exhausted, the
following warnings will be generated.
Viewfinder screen or LCD monitor
When a Status screen is displayed (excluding the Status 2
screen in the Camera mode)
Voltage indication: Blinks
Alarm indication: LOW VOLTAGE displayed.
Viewfinder lamps
BATT lamp and TALLY lamp: Blinks
BACK TALLY lamp on camera: Blinks
Monitoring loudspeaker and PHONES jack: Alarm sound
OPEN
CH-1
AUDIO INPUT
AUDIO SELECT
CH-2
CH-1 CH-2
FRONT
REAR
AUTO
MANUAL
AUDIO
LEVEL
CH-1 CH-2
PULL
OPEN
LCD BRIGHT DISPLAY
LOW VOLTAGE
10.5V
REC
BATT
ALARM
LOW VOLTAGE
10.5V
LCD monitor
TALLY lamp
Viewfinder
Battery lamp
4-2 Battery Pack Operation (Optional) (Cont’d)
37
5. PREPARATIONS
MONITOR
EDITSEARCH
FILTER
STATUS
SHUTTER
MENU
AUTO IRIS
BACK L
NORMAL
SPOT L
STRETCH
NORMAL
COMPRESS
FULL AUTO BLACK LOLUX
MODE
POWER
ON OFF
VTR
OPEN
VTR
CAM
1
3200K
5600K
5600K
5600K
ND
/
/
ND
2
.3
.4
1
8
1
64
CH-1
AUDIO INPUT
AUDIO SELECT
CH-2
CH-1 CH-2
FRONT
REAR
AUTO
MANUAL
AUDIO
LEVEL
CH-1 CH-2
PULL
OPEN
LCD BRIGHT DISPLAY
MENU
AUTO IRIS
BACK L
NORMAL
SPOT L
STRETCH
NORMAL
COMPRESS
FULL AUTO BLACK LOLUX
MODE
POWER
ON OFF
VTR
VTR
CAM
1.
Set the POWER switch to ON.
The unit turns on in Camera mode.
The operation differs according to whether the unit is in the Camera mode or in the VTR mode.
When the MODE switch is pressed upward, the mode is changed.
The Camera indicator or VTR indicator comes on in accordance with the selected mode.
Mode
Camera mode
VTR mode
Operation
The GY-DV5000 enters the record mode. The camera image is displayed in the viewfinder or
on the LCD monitor. When a recordable videocassette is loaded, the GY-DV5000 enters the
record-standby mode automatically. “STBY” is displayed in the VTR operation mode indication
area of the LCD monitor or in the viewfinder. In this condition, press the VTR trigger button to
start recording.
* Playback is also possible in the Camera mode.
Playback operation becomes possible when the STOP button is pressed to set the VTR
operation mode indicator to indicate STOP.
The GY-DV5000 enters the VTR playback mode. The camera image will not be displayed in
the viewfinder or on the LCD monitor. When a videocassette is loaded, the GY-DV5000 enters
the stop mode.
“STOP” is displayed in the VTR operation mode indication area of the LCD monitor or in the
viewfinder.
5-1 Turning the Power ON
MODE
indicator
POWER
switch
MODE
switch
Turning the Power OFF
1.
Place the GY-DV5000 in the record-standby or STOP mode.
2.
Set the POWER switch to OFF.
3.
Remove the battery pack or the power supply to the DC IN connector. (When the camera is not going to be used for a longer
period.)
CAUTION:
Do not set the POWER switch to OFF while recording is taking place.
Confirm that the STBY or STOP indication is shown in the VTR operation mode indication area before the power is turned off.
Should the POWER switch accidentally be set to OFF during a recording, wait at least 5 seconds before turning the power on
again.
Always set the POWER switch to OFF before disconnecting the power supply
Do not turn the battery pack or AC power supply OFF while the POWER switch on the camera is still set to ON.
20

Hulp nodig? Stel uw vraag in het forum

Spelregels

Misbruik melden

Gebruikershandleiding.com neemt misbruik van zijn services uitermate serieus. U kunt hieronder aangeven waarom deze vraag ongepast is. Wij controleren de vraag en zonodig wordt deze verwijderd.

Product:

Bijvoorbeeld antisemitische inhoud, racistische inhoud, of materiaal dat gewelddadige fysieke handelingen tot gevolg kan hebben.

Bijvoorbeeld een creditcardnummer, een persoonlijk identificatienummer, of een geheim adres. E-mailadressen en volledige namen worden niet als privégegevens beschouwd.

Spelregels forum

Om tot zinvolle vragen te komen hanteren wij de volgende spelregels:

Belangrijk! Als er een antwoord wordt gegeven op uw vraag, dan is het voor de gever van het antwoord nuttig om te weten als u er wel (of niet) mee geholpen bent! Wij vragen u dus ook te reageren op een antwoord.

Belangrijk! Antwoorden worden ook per e-mail naar abonnees gestuurd. Laat uw emailadres achter op deze site, zodat u op de hoogte blijft. U krijgt dan ook andere vragen en antwoorden te zien.

Abonneren

Abonneer u voor het ontvangen van emails voor uw JVC GY-DV5000 bij:


U ontvangt een email met instructies om u voor één of beide opties in te schrijven.


Ontvang uw handleiding per email

Vul uw emailadres in en ontvang de handleiding van JVC GY-DV5000 in de taal/talen: Engels als bijlage per email.

De handleiding is 3,75 mb groot.

 

U ontvangt de handleiding per email binnen enkele minuten. Als u geen email heeft ontvangen, dan heeft u waarschijnlijk een verkeerd emailadres ingevuld of is uw mailbox te vol. Daarnaast kan het zijn dat uw internetprovider een maximum heeft aan de grootte per email. Omdat hier een handleiding wordt meegestuurd, kan het voorkomen dat de email groter is dan toegestaan bij uw provider.

Stel vragen via chat aan uw handleiding

Stel uw vraag over deze PDF

loading

Uw handleiding is per email verstuurd. Controleer uw email

Als u niet binnen een kwartier uw email met handleiding ontvangen heeft, kan het zijn dat u een verkeerd emailadres heeft ingevuld of dat uw emailprovider een maximum grootte per email heeft ingesteld die kleiner is dan de grootte van de handleiding.

Er is een email naar u verstuurd om uw inschrijving definitief te maken.

Controleer uw email en volg de aanwijzingen op om uw inschrijving definitief te maken

U heeft geen emailadres opgegeven

Als u de handleiding per email wilt ontvangen, vul dan een geldig emailadres in.

Uw vraag is op deze pagina toegevoegd

Wilt u een email ontvangen bij een antwoord en/of nieuwe vragen? Vul dan hier uw emailadres in.



Info