Type GHV 20 M
Order No. 940 030-061
Frequency range
vorward MHz 85...862
return MHz 5...65
Gain
Output 1 dB 0 12
Output 2, 3, 4 dB - 10.5
Level adjuster dB 0...-20
Noise figure dB 6
Return loss dB 17 16
(min. categ. C) (min. categ. C)
Impedance Ω 75
Output level, IMA = 60 dB
IMA 2 acc. EN 50083-3 dBµV 90
IMA 3 acc. EN 50083-3 dBµV 97
IMA 3 acc. EN 50083-5 dBµV 103
CSO Cenelec 42 ch. 862 MHz dBµV 87
CTB Cenelec 42 ch. 862 MHz dBµV 90
Connected loads
Supply voltage (50 – 60 Hz) VAC 230
Power consumption W 3
Ambient conditions to EN 60065
Operating temperature range °C –25 … +55
Degree of protection II, totally insulated
Protection class IP 20
Housing
Weight kg approx. 0.65
Dimensions W x H x D mm 150 x 80 x 50
Screening attenuation
acc. EN 0083-2, class A dB 75 min
RF connections F connectors